Full-Scale Experimental Verification of Soft-Story-Only Retrofits of Wood-Frame Buildings using Hybrid Testing
Authors:Elaina Jennings  Ershad Ziaei  Pouria Bahmani  Sangki Park  Xiaoyun Shao
Institution:1. Civil and Environmental Engineering Department, Colorado State University, Fort Collins, Colorado, USA;2. Glenn Department of Civil Engineering, Clemson University, Clemson, South Carolina, USA;3. Institute of Construction Technology, Gyeonggi-do, Republic of Korea;4. Civil and Construction Engineering, Western Michigan University, Kalamazoo, Michigan, USA
Abstract:The FEMA P-807 Guidelines were developed for retrofitting soft-story wood-frame buildings based on existing data, and the method had not been verified through full-scale experimental testing. This article presents two different retrofit designs based directly on the FEMA P-807 Guidelines that were examined at several different seismic intensity levels. The effects of the retrofits on damage to the upper stories were investigated. The results from the hybrid testing verify that designs following the FEMA P-807 Guidelines meet specified performance levels and appear to successfully prevent collapse at significantly higher seismic intensity levels well beyond for which they were designed. Based on the test results presented in this article, it is recommended that the soft-story-only retrofit procedure can be followed when financial or other constraints limit the retrofit from bringing the soft-story building up to current code or applying performance-based procedures.
Keywords:Soft-Story  Wood-Frame  Full-Scale Test  Retrofit  FEMA P-807  Hybrid Testing