首页 | 本学科首页   官方微博 | 高级检索  
     


A Five-Step Procedure for the Dimensioning of Viscous Dampers to Be Inserted in Building Structures
Authors:Stefano Silvestri  Giada Gasparini
Affiliation:Department DISTART , University of Bologna , Bologna, Italy
Abstract:Viscous dampers have widely proved their effectiveness in mitigating the effects of the seismic action upon building structures. In view of the large impact that use of such dissipative devices is already having and would most likely have soon in earthquake engineering applications, this article presents a practical procedure for the seismic design of building structures equipped with viscous dampers, which aims at providing practical tools for an easy identification of the mechanical characteristics of the manufactured viscous dampers which allow to achieve target levels of performances. Selected numerical applications are developed with reference to simple, but yet relevant, cases.
Keywords:Added Viscous Dampers  Seismic Design  Design Procedure  Nonlinear Modeling  Damping Ratio