首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Constraints on the precision of SAR in equivalent dose estimations close to saturation in quartz
Authors:Constantin Athanassas
Institution:1.Laboratory of Archaeometry,Institute of Materials Science, N.C.S.R. ‘Demokritos’,Athens,Greece
Abstract:Difficulties in evaluating accurate equivalent doses for Late Quaternary sediments from the south coasts of Greece arose in the course of SAR measurements. Large scatter among apparent equivalent doses perplexed the evaluation of accurate mean estimates in circumstances where very large doses were involved. Besides, dose recovery experiments revealed that when intersection of the natural signal occurs onto the saturating segment of the growth curve, a distinct relationship between De and growth curve shape occurs. At very low slope angles, SAR tends to overestimate the recovered dose. The mechanism which controls the spread in equivalent dose estimation is investigated.