Residual doses and sensitivity change of post IR IRSL signals from potassium feldspar under different bleaching conditions
Authors:Yiwei Chen  Sheng-Hua Li  Bo Li
Affiliation:1. Department of Earth Sciences, The University of Hong Kong, Pokfulam Road, Hong Kong, China
2. Centre for Archaeological Science, School of Earth and Environmental Sciences, University of Wollongong, Wollongong, NSW, 2522, Australia
Abstract:The residual doses and sensitivity change for potassium-rich feldspar (K-feldspar) have been studied using the post-infrared infrared stimulated luminescence (pIRIR) and multi-elevated-temperature post-IR IRSL (MET-pIRIR) protocols. Laboratory simulated poorly-bleached and well-bleached samples were those K-feldspar grains bleached using a solar simulator for 10 minutes and 8 hours, respectively. The residual doses rise with stimulation temperature and time. The poorly-bleached sample has larger residual doses than the well-bleached sample, especially at high stimulation temperatures. The high-temperature pIRIR signals contain a large amount of hard-to-bleach signals. A decrease of luminescence sensitivity was observed after conducting a high-temperature-treatment in the measurement cycles. The sensitivity decreases significantly between the first and the second cycle. The extent of decrease in sensitivity shows a clear temperature trend. The higher the stimulation temperature of pIRIR signals is, the larger the sensitivity decreases. This decrease is more severe for the poorly-bleached sample than for the well-bleached sample, and could possibly lead to problems in sensitivity correction.
Keywords:
本文献已被 SpringerLink 等数据库收录!