首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   22篇
  免费   0篇
  2020年   1篇
  2019年   1篇
  2018年   3篇
  2017年   2篇
  2014年   1篇
  2013年   12篇
  2009年   1篇
  2000年   1篇
排序方式: 共有22条查询结果,搜索用时 15 毫秒
1.
Ground-supported steel tanks experienced extensive damage in past earthquakes. The failure of tanks in earthquakes may cause severe environmental damage and economic losses. This study deals with the evaluation of the elastic buckling of above-ground steel tanks anchored to the foundation due to seismic shaking. The proposed nonlinear static procedure is based on the capacity spectrum method (CSM) utilized for the seismic evaluation of buildings. Different from the standard CSM, the results are not the base shear and the maximum displacement of a characteristic point of the structure but the minimum value of the horizontal peak ground acceleration (PGA) that produces buckling in the tank shell. Three detailed finite element models of tank-liquid systems with height to diameter ratios H/D of 0.40, 0.63, and 0.95 are used to verify the methodology. The 1997 UBC design spectrum and response spectra of records of the 1986 El Salvador and 1966 Parkfield earthquakes are used as seismic demand. The estimates of the PGA for the occurrence of first elastic buckling obtained with the proposed nonlinear static procedure were quite accurate compared with those calculated with more elaborate dynamic buckling studies. For all the cases considered, the proposed methodology yielded slightly smaller values of the critical PGA for the first elastic buckling compared to the dynamic buckling results.  相似文献   
2.
A direct methodology for solving the seismic intensity of each point on the capacity curve is proposed. By utilizing the procedure, a continuous curve between the structural response and the seismic intensity, the structural response function, can be easily generated. Unlike previous procedures that search for the performance point of a determined seismic intensity, the proposed methodology easily draws the full curve without iterations. The procedure is applicable to both a smooth design spectrum and an actual response spectrum. Examples indicate the methodology is accurate and fast, and convenient to be combined with existing procedures, such as Modal Pushover Analysis.  相似文献   
3.
The seismic assessment of special bridges, even under the hypothesis of full knowledge of site conditions, structural characteristics, and seismic activity at their location, is not an easy and straightforward task due to the complexities and uncertainties related to the finite-element modeling approaches, structural loading scenarios, and seismic analysis methodologies. In this article, a series of nonlinear static and dynamic finite-element analyses on the Mogollon Rim Viaduct are performed with consideration of both uniform and conditionally simulated non-uniform seismic motions. The failure modes of the bridge using different numerical modeling approaches are discussed, and the degree of sensitivity of its response to the different seismic assessment strategies is evaluated. The effect of the multi-component, multi-support and multi-directional excitations of ground motions on the design and response are studied, and the pros and cons of the commonly used structural analysis methodologies of bridges are also addressed. The numerical results of the present study provide a deeper insight into the nonlinear behavior of curved reinforced-concrete bridges, and suggest practice-oriented approaches for their seismic assessment.  相似文献   
4.
档案库房空气净化的研究   总被引:1,自引:0,他引:1  
为解决大面积库房的空气净化问题,利用中央空调设备的送回风循环系统,采用灭菌型空气净化专利技术对库房空气净化处理。研究结果证明,被测环境中有害气体组分明显下降,霉菌菌落均有减少。对调节空气和改善库房内的空气质量起到了良好效果。  相似文献   
5.
This article describes a simplified procedure for estimating the seismic sidesway collapse capacity of frame building structures incorporating linear viscous dampers. The proposed procedure is based on a robust database of seismic peak displacement responses of viscously damped nonlinear single-degree-of-freedom systems for various seismic intensities and uses nonlinear static (pushover) analysis without the need for nonlinear time history dynamic analysis. The proposed procedure is assessed by comparing its collapse capacity predictions on 272 different building models with those obtained from incremental dynamic analyses. A straightforward collapse capacity-based design procedure is also introduced for structures without extreme soft story irregularities.  相似文献   
6.
A complete structural analysis of the bell tower of Santa Maria del Carmine in Naples (Italy) has been developed by using a 3D FE model based on the results of detailed experimental investigations in situ. Linear analysis for gravity loads, linear modal analysis, and nonlinear static analysis (Push Over) were carried out in order to assess the seismic capacity of the structure. A check of local out-of-plane failure mechanisms was also performed to verify if the structure is able to attain a global behavior. Problems and solutions related to the different methods are presented and discussed.  相似文献   
7.
This article presents the comparison among different nonlinear seismic analysis methods applied to masonry buildings, i.e., pushover analyses with invariant lateral force distributions, adaptive pushover analysis and nonlinear dynamic analysis. The study focuses on the influence of lateral force distribution on the results of the pushover analysis. Two simple benchmark case studies are considered for the purpose of the research, i.e., a four-wall masonry building prototype without floor rigid diaphragms and a two-wall system with a cross-vault. The comparative study offers a useful review of pushover analysis methods for masonry structures and shows advantages and possible limitations of each approach.  相似文献   
8.
A prototype diesel generator equipped with a vibration isolation system consisting of restrained isolators (denoted as I/system) is quasi-statically and dynamically tested. Sequentially, the seismic simulation tests are conducted to further investigate the effectiveness of additional snubbers incorporated into the vibration isolation system (denoted as I/R system). Comparing the test results to the static design demands specified in ASCE 7-10, the recommended component amplification factor could represent the horizontal acceleration amplification phenomenon of the generator equipped with I/R system; however, the seismic force demands for static design of I/R system might not be appropriate and conservative enough.  相似文献   
9.
Traditional or historic masonry structures occur in large populations throughout the world, particularly in preserved historical city clusters. Being non-engineered and aging these structures are in urgent need of assessment and seismic repair/rehabilitation. However, traditional masonry presents important challenges to computational modeling, owing to complexity of structural system, material inhomogeneity, and contact interactions that collectively can only be addressed through detailed 3D nonlinear representation. In this article, a simple performance assessment model is developed in order to address the need for preliminary assessment tools for this class of structures. The objective is to be able to rapidly identify buildings that are at higher risk in the event of a significant earthquake, potentially justifying a second round of more detailed evaluation. The proposed model defines the characteristics of a Single Degree of Freedom representation of the building, formulating consistent 3D shape functions to approximate its fundamental mode of vibration considering both in-plane and out-plane wall bending as a result of insufficient diaphragm action. Parametric expressions for the dynamic properties are derived in terms of the important geometric, material, and system characteristics, and are used to express local demand from global estimates. Acceptance criteria are established both in terms of deformation and strength indices to guide retrofit. An application example of the proposed assessment methodology is included to demonstrate the ability of the model to reproduce the essential features of traditional masonry buildings under seismic action.  相似文献   
10.
Masonry building aggregates are large parts of the Italian building heritage often designed without respecting seismic criteria. The current seismic Italian code does not foresee a clear calculation method to predict their static nonlinear behavior. For this reason, in this article a simple methodology to forecast the masonry aggregate seismic response has been set up. The implemented procedure has been calibrated on the results of two FEM structural analysis programs used to investigate three masonry building compounds. As a result, a design chart used to correctly predict the base shear of aggregate masonry units starting from code provisions has been set up.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号