首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   58篇
  免费   0篇
  2020年   1篇
  2019年   5篇
  2018年   8篇
  2014年   8篇
  2013年   33篇
  2012年   2篇
  2010年   1篇
排序方式: 共有58条查询结果,搜索用时 312 毫秒
1.
Shear walls are important lateral force-resistant components of tall buildings. Hence, a reliable numerical model that can accurately represent the mechanical characteristics and large deformations of shear walls is critical for realistic collapse simulation of tall buildings. Based on the theory of generalized conforming element, a high-performance quadrilateral flat shell element, NLDKGQ, accounting for the large deformation using the updated Lagrangian formulation, is proposed herein and implemented in OpenSees. The reliability of NLDKGQ is validated using classical benchmark problems and reinforced concrete specimens. In addition, its capability in simulating the collapse of a tall building is also demonstrated.  相似文献   
2.
A simplified model useful for assessing economic losses due to moderate seismicity events in urban areas has been developed by studying the behavior of buildings before yielding their structural system, allowing for nonuniform stiffness along their height. In particular, buildings are modeled as cantilever shear beams with uniform mass and parabolic reduction of lateral stiffness. This particular stiffness distribution is relevant, as it could be expected to occur in buildings where earthquake action is a critical structural design criterion. The equation of motion governing the dynamic behavior of the proposed model is solved analytically, finding mode shapes in terms of first and second zero-order Legendre functions. The solution is verified by comparing it with results obtained from fine mesh finite element models. The effect of reducing the lateral stiffness is then studied in the first five modes of vibration. Results include modal periods, mode shapes, modal participation factors, and derivatives of mode shapes. In general, it is found that effects of reduction of lateral stiffness in mode shapes are moderate when the lateral stiffness in the free end is smaller than about seventy percent of the lateral stiffness at the fixed end, but become significant for larger reductions. Effects are particularly important for the derivative of the mode shapes, which could play a significant role in estimating interstory drift demands in buildings. Model usefulness is showcased by analyzing a test case where both acceleration and drift demands are assessed by considering uniform beams and beams with parabolic stiffness variation, finding notable improvements by considering the latter.  相似文献   
3.
The concept of providing a fuse in a structural system has been both developed and investigated over the past few years (e.g., the use of replaceable links in eccentrically braced frames or the use of replaceable links in the new San Francisco-Oakland Bay Bridge). This paper presents a new coupling beam with a creative fuse installed in the mid-span of a steel-concrete composite beam via an end plate and high-strength bolts. First, a practical design methodology of a replaceable coupling beam is presented. Next, the seismic behavior of the proposed fuse is tested and evaluated, and two structural wall specimens with or without a fuse are designed and fabricated according to the proposed design methods. The two specimens possess similar shear capacities under large-scale cyclic loading, and the walls of the two specimens show similar failure modes; however, the new walls exhibit slightly lower levels of damage than the conventional walls. In particular, the inelastic deformation and damage of replaceable coupling beams are mainly concentrated in the fuse, whereas the non-yield segment and the beam-wall pier interfaces remain nearly intact and produce only slight damage, which is beneficial regarding the replacement of the fuse in post-earthquake events.  相似文献   
4.
In this study, stress-controlled cyclic simple shear tests were performed on sand specimens with up to 10% silt or clay contents, and coupled effects of plasticity, fines content (FC), relative density (DR) and CSR (cyclic stress ratio) were investigated. The results demonstrated that for sands with low fines content, reasonable trends were obtained when the packing index control parameter was selected as DR. Also, clean sand specimens demonstrated highest liquefaction strength compared with that of sands with fines up to 10% FC. The effect of fines’ plasticity became apparent as the FC increases and CSR reduces in relatively denser specimens.  相似文献   
5.
Capacity design aims to ensure controlled ductile response of structures when subjected to earthquakes. This article investigates the performance of existing capacity design equations for reinforced concrete coupled walls and then proposes a new simplified capacity design method based on state-of-the-art knowledge. The new method is verified through a case study in which a set of 15 coupled walls are subject to nonlinear time-history analyses. The article includes examination of the maximum shear force in individual walls in relation to the total maximum shear force in the coupled wall system, and subsequently provides recommendations for design.  相似文献   
6.
孟华平  刘辉  邓振华  向其芳 《考古》2012,(8):29-41,1,103,105
2011年,湖北省文物考古研究所、北京大学考古文博学院对石家河古城三房湾遗址的东南低洼地带进行了勘探和发掘,证实该处存在城垣堆积,且走向明确。城垣的兴建年代不早于屈家岭文化晚期,至石家河文化晚期已经废弃。此次工作,为全面认识石家河古城的结构以及聚落变迁提供了重要的资料。  相似文献   
7.
It has been pointed out that the static lateral response procedure for base isolated structures presented in IBC somewhat overestimates the seismic story force [Lashkari and Kircher, 1993 Lashkari, B. and Kircher, C. A. . Evaluation of SEAOC/UBC analysis procedures, Part 1: Stiff superstructure. Proceedings of a Seminar on Seismic Isolation, Passive Energy Dissipation and Active Control. Redwood City, California. ATC Report 17-1.  [Google Scholar]; Constantinou et al., 1993 Constantinou, M. C., Winters, C. W. and Theodossiou, D. . Evaluation of SEAOC and UBC analysis procedures, Part 2: Flexible Superstructure. Proceedings of a Seminar on Seismic Isolation, Passive Energy Dissipation and Active Control. Redwood City, California. ATC Report 17-1.  [Google Scholar]]. In this article IBC equivalent static method for base shear distribution of seismic isolated structures is evaluated. For this purpose one-story to six-story building models are designed according to equivalent lateral response procedure for different elastomeric isolation systems. The results of equivalent lateral response procedure in parameters such as base shear and vertical distribution of base shear are compared with results obtained from dynamic nonlinear analysis and the efficiency and limitations of its application are investigated. In general, the results of equivalent lateral response procedure in base shears are acceptable within the scope of this procedure, but the proposed triangular distribution of base shear is somewhat conservative. So a new formulation for vertical distribution of base shear is proposed which results in a more realistic distribution of shear over the height of isolated buildings. The accuracy of the new formulation is examined by comparing the resulting responses obtained from this study with those calculated by nonlinear time history analysis.  相似文献   
8.
Self-centering ability of unbonded post-tensioned precast concrete shear walls has been attributed to the presence of post-tensioning force. However, the experimental results presented in this paper indicate that the post-tensioning force may completely die out during cyclic loading while the walls are able to retain their superior self-centering characteristic. Moreover, the analytical study presented in this article indicates that with proper configuration of end-anchorages for post-tensioned tendons, self-centering of post-tensioned walls can be achieved even when the post-tensioning force vanishes. This study also investigates the effects of tendon layout, tendon end-anchorage configuration, and external vertical load on the self-centering ability of unbonded precast concrete shear walls subjected to earthquake loading.  相似文献   
9.
This study is aimed at investigating the demand on shear panel dampers (SPDs) installed in steel structures under strong earthquake motions to serve as guidance for the recommended capacity of SPDs in seismic design. For this purpose, an extensive dynamic analysis is carried out on steel bridge pier structures with SPD devices. To describe the restoring force characteristics of SPDs, the analysis uses a newly developed combined hardening model based on experimental data. The seismic demands made on SPD devices are examined and then summarized to give recommended values for determining the necessary deformation capacity of SPDs.  相似文献   
10.
Concrete shear walls are widely employed in buildings as a main resistance system against lateral loads. Early identification of seismic damage to concrete shear walls is vital for deciding post-earthquake occupancy in these structures. In this article, a method based on artificial neural networks for real-time identification of seismic damage to concrete shear walls was proposed. Inter-story drifts and plastic hinge rotation of concrete walls were used as the inputs and outputs of a MLP neural network. Modal Pushover Analysis was employed to prepare well-distributed data sets for training the neural network. The proposed method was applied to a five-story concrete shear wall building. The results from the network were compared with those obtained from Nonlinear Time History Analysis. It was observed that the trained neural network successfully detected damage to concrete shear walls and accurately estimated the severity of seismic-induced damage.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏