首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   97篇
  免费   0篇
  2020年   2篇
  2019年   9篇
  2018年   14篇
  2016年   1篇
  2014年   13篇
  2013年   55篇
  2009年   1篇
  2005年   1篇
  2001年   1篇
排序方式: 共有97条查询结果,搜索用时 15 毫秒
1.
Seismic assessment of gravity dams is generally carried out using time history analyses. Scaling of the motions is commonly used; however, in contrast to buildings, the performance of scaling procedures at predicting the mean and reducing the dispersion in engineering demand parameters (EDPs) is not known. The main goal of this study is to assess the performance of different scaling procedures in predicting seismic demands on dams. The performance regarding the prediction of the damage and the required number of motions for effective analysis was investigated. The results show that techniques commonly used for moment frames should not readily be applied to these structures.  相似文献   
2.
Controlled rocking heavy timber walls are designed to rock on their foundations in response to earthquakes. For regions of moderate seismicity, it is proposed that this rocking behaviour can be adequately controlled using only post-tensioning, even with a large force-reduction factor and no supplemental energy dissipation. This article presents a force-based design procedure for controlled rocking cross-laminated timber walls without supplemental energy dissipation, including a method for estimating higher mode effects. Fragility analyses of three prototype walls demonstrate that the procedure can limit the probability of collapse to <10% during a maximum considered earthquake in a region of moderate seismicity.  相似文献   
3.
Capacity design aims to ensure controlled ductile response of structures when subjected to earthquakes. This article investigates the performance of existing capacity design equations for reinforced concrete coupled walls and then proposes a new simplified capacity design method based on state-of-the-art knowledge. The new method is verified through a case study in which a set of 15 coupled walls are subject to nonlinear time-history analyses. The article includes examination of the maximum shear force in individual walls in relation to the total maximum shear force in the coupled wall system, and subsequently provides recommendations for design.  相似文献   
4.
Field investigations after the recent Tohoku and Christchurch earthquakes reported failure of structural systems due to multiple earthquakes. In most failure cases the reported damage was mainly due to dramatic loss of stiffness and strength of structural elements as a result of material deterioration due to repeated earthquake loading. This study aims to investigate the degrading behavior of reinforced concrete frame systems subjected to Tohoku and Christchurch earthquake sequences. Numerical models of RC frames that incorporate damage features are established and inelastic response history analyses are conducted. The results presented in this study indicate that multiple earthquake effects are significant.  相似文献   
5.
It has been pointed out that the static lateral response procedure for base isolated structures presented in IBC somewhat overestimates the seismic story force [Lashkari and Kircher, 1993 Lashkari, B. and Kircher, C. A. . Evaluation of SEAOC/UBC analysis procedures, Part 1: Stiff superstructure. Proceedings of a Seminar on Seismic Isolation, Passive Energy Dissipation and Active Control. Redwood City, California. ATC Report 17-1.  [Google Scholar]; Constantinou et al., 1993 Constantinou, M. C., Winters, C. W. and Theodossiou, D. . Evaluation of SEAOC and UBC analysis procedures, Part 2: Flexible Superstructure. Proceedings of a Seminar on Seismic Isolation, Passive Energy Dissipation and Active Control. Redwood City, California. ATC Report 17-1.  [Google Scholar]]. In this article IBC equivalent static method for base shear distribution of seismic isolated structures is evaluated. For this purpose one-story to six-story building models are designed according to equivalent lateral response procedure for different elastomeric isolation systems. The results of equivalent lateral response procedure in parameters such as base shear and vertical distribution of base shear are compared with results obtained from dynamic nonlinear analysis and the efficiency and limitations of its application are investigated. In general, the results of equivalent lateral response procedure in base shears are acceptable within the scope of this procedure, but the proposed triangular distribution of base shear is somewhat conservative. So a new formulation for vertical distribution of base shear is proposed which results in a more realistic distribution of shear over the height of isolated buildings. The accuracy of the new formulation is examined by comparing the resulting responses obtained from this study with those calculated by nonlinear time history analysis.  相似文献   
6.
This article proposes a damage index for the seismic analysis of Reinforced Concrete members using the hysteretic energy dissipated by a structural member and a drift ratio related to failure in the structure. The index was calibrated against observed damage in laboratory tests of 76 RC column units under various protocols. Values obtained in this calibration had acceptable agreement with the levels of damage observed in the test specimens. An analysis of the parameters involved in the definition of the proposed damage index shows the importance of displacement history in the drift ratio capacity of structures.  相似文献   
7.
There are many reinforced concrete structures throughout the world that have been built in the past decades that lack appropriate seismic details and reinforced by plain bars. To study the behavior of such buildings, seven beams have been tested under cyclic and monotonic load. The specimens include substandard specimens, with deficient seismic details and reinforced by plain bars, specimens designed in accordance with ACI-318-99 but reinforced by plain bars, and standard specimens reinforced by deformed bars. The tests indicate that the substandard specimens sustain relatively large slip of longitudinal bars, separation of specimen relative to foundation and sliding at large deformation phase, low initial stiffness ratio, limited lateral displacement capacity, and loss of nominal yield strength. The specimens reinforced by plain bars in accordance with ACI-318-99 perform almost similar to standard specimens with deformed bars, in terms of elastic stiffness and lateral displacement ductility; but, they sustain larger slip, and smaller yield strength. Failure of all specimens reinforced by plain bars is characterized by flexural cracks without visible shear failure. Residual shear strength of substandard specimens is modeled by dowel action of longitudinal bars to predict a lower limit for lateral strength of the specimens.  相似文献   
8.
Self-centering ability of unbonded post-tensioned precast concrete shear walls has been attributed to the presence of post-tensioning force. However, the experimental results presented in this paper indicate that the post-tensioning force may completely die out during cyclic loading while the walls are able to retain their superior self-centering characteristic. Moreover, the analytical study presented in this article indicates that with proper configuration of end-anchorages for post-tensioned tendons, self-centering of post-tensioned walls can be achieved even when the post-tensioning force vanishes. This study also investigates the effects of tendon layout, tendon end-anchorage configuration, and external vertical load on the self-centering ability of unbonded precast concrete shear walls subjected to earthquake loading.  相似文献   
9.
The first step in a hysteretic energy-based design approach of performance-based design is the estimation of hysteretic energy demand in the structure. A nonlinear response-history analysis of the multi-degree of freedom model gives an accurate estimation, but it is not suitable for adopting in design. Two alternative methods, based on the concepts of modal pushover analysis (MPA) and 2D-MPA, are proposed in this article for uniaxial plan-asymmetric structures. Application studies show that both methods are efficient. While the 2D-MPA-based method is more accurate, the MPA-based method is more suitable for design adoption. Significant conclusions are given for prospective application of these methods.  相似文献   
10.
Acceleration response of simple yielding structure is proportional to its own weight, but it is limited by yield strength. Thus, using rocking columns that reduces global yield strength, a limited acceleration is achieved. However, the displacement becomes large due to lower strength and higher inelasticity, but it can be controlled by adding damping. Performing fragility analyses, the seismic response of R/C frame structures with rocking columns and viscous dampers is investigated. Near field MCEER ground motions are considered. The analyses show that the story accelerations are reduced by using rocking columns, while the story displacements are controlled by using viscous dampers.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号