首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   3篇
  免费   0篇
  2020年   1篇
  2016年   1篇
  2014年   1篇
排序方式: 共有3条查询结果,搜索用时 0 毫秒
1
1.
ABSTRACT

The interest in automatic modal parameter extraction techniques has increased significantly in recent years because of the rising demand for Continuous Structural Health Monitoring (CSHM) of civil structures and infrastructures. The wider use of CSHM is related to its capability for early damage detection and therefore to its usefulness for planning maintenance and strengthening interventions. This article presents the main steps followed in creating a robust routine to run on an online basis the first-ever Continuous Vibration-Based Structural Health Monitoring (CVB-SHM) of a large masonry oval dome, i.e., the dome of the Regina Montis Regalis Basilica, also known as Sanctuary of Vicoforte. The procedure uses an output-only stochastic subspace identification method complemented by an automatic analysis applied to identification results, which are typically provided in terms of stabilization diagrams. In this study, the fully automatic procedure also includes a hierarchical clustering algorithm to separate authentic from spurious modes.  相似文献   
2.
The Basilica of San Francesco in Assisi endured stronger earthquakes for centuries before 1997 earthquake, which generated the collapse of the two vaults. Experts blame as possible reasons of collapse the damage cumulated from previous earthquakes and/or the retrofitting made to the structure over its lifetime. This article presents the history of the retrofit interventions of the Basilica through the centuries, focusing mainly on the roof, which has been subjected to three major restorations through its life. It is shown using simple analytical models that the cumulative effects of the changes made to the roof of the Basilica affected the structure’s dynamic behavior in a negative manner, increasing the seismic loads on the existing structural members. In particular, the numerical results show that the 1958 roof intervention has stiffened the structure, redistributing the seismic loads on the façade and the transept. This overload might explain the collapse of the two Gothic vaults during 1997 earthquake.  相似文献   
3.
In the framework of the EU–UNDP project ‘Rehabilitation of Old Nicosia’ (Cyprus, 2004–9), a high‐resolution geoelectrical survey has been performed inside the partially ruined monumental complex of St Nicholas of the English, now called the Bedestan, which was designed to become a venue space for cultural activities. The aim was to detect buried traces of a Byzantine basilica of the sixth century, on the ruins of which, according to tradition, the construction of St Nicholas was begun in the 12th century. The survey has been conducted on the floor of the monument, using a dipole–dipole electrode array along two perpendicular sets of profiles. In order to model the resistivity distribution, the probability‐based electrical resistivity tomography inversion (PERTI) method has been applied. Sets of aligned blocks with resistivity in the range 100–400 ohm·m, bounding a three‐room rectangular space, and traces of a rounded structure with mean resistivity about 150 ohm·m, appearing at one extremity of the central room, are the main resistive features recognized down to 4 m depth, within a conductive background with resistivity in the range 20–40 ohm·m. Altogether, these resistive features, showing in plan the shape of a church characterized by a central nave with an apse and two side aisles, have been interpreted as an evidence of the existence of remains of the earlier Byzantine basilica. Moreover, small volumes with resistivity in the range 10–12.6 ohm·m have been found, scattered underneath the whole surveyed area. Taking into account the PERTI results, ground‐truth has been performed in two sites, designed to become two permanent protected exposures of the archaeological findings beneath the floor of the newly restored Bedestan. At one site, excavations detected remains of masonry in correspondence of the alignment of resistive blocks at the left margin of the left side aisle of the churchlike structure. At the other site, graves, entirely filled with wet debris in an alluvial soil matrix, have, instead, been found in correspondence with the greatest conductive volume, detected outside the perimeter of the churchlike structure. Both findings have been dated back to the sixth century. Since the Bedestan case‐history is one of the first applications of the PERTI algorithm to real field data sets, its performance has been tested using the well‐known ERTLabTM commercial software as benchmark. The comparison has shown a general consistency between the two inversions, and also confirmed the much higher computing speed, better filtering capacity and greater versatility of the PERTI algorithm, already outlined in a previous paper where only synthetic models were tested.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号