1.
文物防震措施研究初探   总被引:3,自引:3,他引:0  
台北故宫博物院珍藏中国历代名瓷和玉器其数量和种类居全世界博物馆之冠,目前陈列柜内瓷器及玉器的防震措施仍有改善的空间,因此运用现代科学方法和仪器研究文物防震措施,更突显其重要性和迫切性。本研究使用的方法为传统文物防震措施(使用微晶蜡固定、铁弗龙、橡胶垫和防震塑料垫衬底)、柜内型隔震台减震和电磁铁固定陈列柜功能性测试;运用台湾地震工程研究中心的人工地震台执行上述不同方法之实验。实验结果,传统方法抗震优劣顺序为:微晶蜡>铁弗龙>塑料垫>橡胶垫;柜内型隔震台消能减震功效可达60%;至于电磁铁固定陈列柜防震在加速度超过800gal时,才显现摇摆现象,未装电磁铁的陈列柜,加速度超过300gal时,即有自震现象。然而在瓷器、玉器陈列柜内实务执行防震措施的层面,宜使用微晶蜡固定最为经济有效,柜内型隔震台亦可使用,但需考量柜内可滑动空间是否充裕的实际状况执行。  相似文献   
2.
It has been pointed out that the static lateral response procedure for base isolated structures presented in IBC somewhat overestimates the seismic story force [Lashkari and Kircher, 1993 Lashkari, B. and Kircher, C. A. . Evaluation of SEAOC/UBC analysis procedures, Part 1: Stiff superstructure. Proceedings of a Seminar on Seismic Isolation, Passive Energy Dissipation and Active Control. Redwood City, California. ATC Report 17-1.  [Google Scholar]; Constantinou et al., 1993 Constantinou, M. C., Winters, C. W. and Theodossiou, D. . Evaluation of SEAOC and UBC analysis procedures, Part 2: Flexible Superstructure. Proceedings of a Seminar on Seismic Isolation, Passive Energy Dissipation and Active Control. Redwood City, California. ATC Report 17-1.  [Google Scholar]]. In this article IBC equivalent static method for base shear distribution of seismic isolated structures is evaluated. For this purpose one-story to six-story building models are designed according to equivalent lateral response procedure for different elastomeric isolation systems. The results of equivalent lateral response procedure in parameters such as base shear and vertical distribution of base shear are compared with results obtained from dynamic nonlinear analysis and the efficiency and limitations of its application are investigated. In general, the results of equivalent lateral response procedure in base shears are acceptable within the scope of this procedure, but the proposed triangular distribution of base shear is somewhat conservative. So a new formulation for vertical distribution of base shear is proposed which results in a more realistic distribution of shear over the height of isolated buildings. The accuracy of the new formulation is examined by comparing the resulting responses obtained from this study with those calculated by nonlinear time history analysis.  相似文献   
3.
Elastomeric pad bearings are widely applied in short- to medium-span girder bridges in China, with the superstructure restrained by reinforced concrete (RC) shear keys in the transverse direction. Field investigations after the 2008 Wenchuan earthquake reveal that bearing systems had suffered the most serious damage, such as span falling, bearing displaced, and shear key failure, while the piers and foundations underwent minor damage. As part of a major study on damage mechanism and displacement control method for short- to medium-span bridges suffered in Wenchuan earthquake, a 1:4 scale, two-span bridge model supported on elastomeric pad bearings were recently tested on shake tables at Tongji University, Shanghai. The bridge model was subjected to increasing levels of four seismic excitations possessing different spectral characteristics. Two restraint systems with and without the restraint of RC shear keys were tested. A comprehensive analytical modeling of the test systems was also performed using OpenSees. The experimental results confirmed that for the typical bridges on elastomeric pad bearings without RC shear keys, the sliding effect of the elastomeric pad bearings plays an important role in isolation of ground motions and, however, lead to lager bearing displacement that consequently increases the seismic risk of fall of span, especially under earthquakes that contain significant mid-period contents or velocity pulse components. It is suggested from the test results that RC shear keys should be elaborately designed in order to achieve a balance between isolation efficiency and bearing displacement. Good correlation between the analytical and the experimental data indicates that the analytical models for the bearing and RC shear key as well as other modeling assumptions were appropriate.  相似文献   
4.
Comparative study of numerically and experimentally obtained seismic responses of un-reinforced masonry building supported on in-house designed un-bonded fibre reinforced elastomeric isolator (U-FREI) are presented in this article. The effectiveness of U-FREI is established very clearly in terms of controlled dynamic response of the model building. Experimental studies are carried out on a shake table with elaborate instrumentations for measurement of acceleration and displacements at different floor levels. Numerical study of the model building supported on U-FREI is carried out to compare the results with experimental investigation. Multi-linear pivot hysteretic plasticity model is used to simulate the behavior of FREI, while plate elements are used for brick-masonry walls. Experimentally obtained force-displacement curves of FREI are used for defining the properties of multi-linear model representing FREI. The dynamic responses obtained from the numerical studies are compared with those from experimental investigations. This study indicates that the seismic responses of building supported on U-FREI can be numerically evaluated with quite reasonable accuracy. A good numerical model can be judiciously used at the preliminary design stage, followed by actual testing and construction of the base isolated building.  相似文献   
5.
通过对博物馆内物浮放物体的地震危害性分析,指出了物防震的一些主要问题。归纳总结了馆藏物的传统抗震措施。阐述了现代隔震技术的发展、研究现状以及隔震装置在物防震工作中的应用情况。同时给出了博物馆物防震保护的设计方案。  相似文献   
6.
The seismic response of base-isolated benchmark building with variable sliding isolators like variable friction pendulum system (VFPS), variable frequency pendulum isolator (VFPI), and variable curvature friction pendulum system (VCFPS), along with conventional friction pendulum system (FPS), was studied under the seven earthquakes. The earthquakes are applied bi-directionally in the horizontal plane ignoring vertical ground motion component. The shear type base-isolated benchmark building is modeled as three-dimensional linear elastic structure having three degrees of freedom at each floor level. Time domain dynamic analysis of the benchmark building was carried out with the help of constant average acceleration Newmark-Beta method and nonlinear isolation forces was taken care by fourth-order Runge-Kutta method. The base-isolated benchmark building is investigated for uniform isolation and hybrid isolation in combination with laminated rubber bearings through the performance criteria and time history response of important structural response parameters like floor accelerations, base displacement, etc. It is observed that variable sliding isolators performed better than conventional FPS due to their varying characteristic properties which enable them to alter the isolator forces depending upon their isolator displacements thus improves the performance of the structure. The VFPS efficiently controls large isolator displacements and VFPI and VCFPS improve super structural response on the cost of isolator displacement. It is also observed that the hybrid isolation is relatively better in comparison to the uniform isolation for the benchmark building.  相似文献   
7.
A prototype diesel generator equipped with a vibration isolation system consisting of restrained isolators (denoted as I/system) is quasi-statically and dynamically tested. Sequentially, the seismic simulation tests are conducted to further investigate the effectiveness of additional snubbers incorporated into the vibration isolation system (denoted as I/R system). Comparing the test results to the static design demands specified in ASCE 7-10, the recommended component amplification factor could represent the horizontal acceleration amplification phenomenon of the generator equipped with I/R system; however, the seismic force demands for static design of I/R system might not be appropriate and conservative enough.  相似文献   
8.
The unseating of decks is one of the most prevalent failure modes of bridges after earthquake events, as observed in the 2010 Chile Earthquake. Damaged bridges in Chile often had skew angles and were supported on elastomeric bearings. Similar bridge construction practices with decks supported on elastomeric bearings are also common in the central and eastern U.S. (CEUS). The seismic displacement demands on skewed bridges are more complicated than those on bridges without skew angles due to the coupling of translational modes with the rotational mode of vibration. The study presented in this article seeks to understand the seismic response of skewed bridge decks supported on elastomeric bearings. The scope of the study is limited to one- and two-span bridges, which constitute a large portion of bridge inventory in the CEUS. The vibration modes of skewed bridge decks are derived in closed form and the modes are compared when the gaps between the bridge deck and the abutment are open and when one of the gaps is closed due to seismic excitation. Nonlinear response history analyses are carried out to understand the effects of vertical ground motion, skew angles, aspect ratios, and different ground motion types on the seismic displacement demand in these cases. Amplification factors that approximate the increase in the displacement demand due to the skew angle are proposed.  相似文献   
9.
在对文物进行保护处理过程中,清洗是非常重要工作之一。新的清洗材料、清洗工艺的研究,对文物保护技术的发展具有重要价值。本研究对Carbopol 934树脂应用于纺织品清洗的清洗效果、清洗工艺进行了研究,并对其在纸张和砖石文物上应用的可能性进行了尝试。研究结果表明,Carbopol 934树脂应用在纺织品清洗中具有作用时间长、扩散小的优点;同时应用隔离层能减少残留,达到更好的清洗效果;可有效地用于砖石、纸张和织物上污垢的去除。  相似文献   
10.
The concept of base isolation is a century old, but application to civil engineering structures has only occurred over the last several decades. Application to light-frame wood buildings in North America has been virtually non existent with one notable exception. This article quantitatively examines issues associated with application of base isolation in light-frame wood building systems including: (1) constructability issues related to ensuring sufficient in-plane floor diaphragm stiffness to transfer shear from the superstructure to the isolation system; (2) evaluation of experimental seismic performance of a half-scale base-isolated light-frame wood building; and (3) development of a displacement–based seismic design method and numerical model and their comparison with experimental results. The results of the study demonstrate that friction pendulum system (FPS) bearings offer a technically viable passive seismic protection system for light-frame wood buildings in high seismic zones. Specifically, the amount and method of stiffening the floor diaphragm is not unreasonable, given that the inter-story drift and accelerations at the upper level of the tested building were very low, thus resulting in the expectation of virtually no structural, non structural, or contents damage in low-rise wood frame buildings. The nonlinear dynamic model was able to replicate both the isolation layer and superstructure movement with good accuracy. The displacement-based design method was proven to be a viable tool to estimate the inter-story drift of the superstructure. These tools further underscore the potential of applying base isolation systems for application to North America's largest building type.  相似文献   