首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   43篇
  免费   0篇
  2019年   4篇
  2018年   8篇
  2016年   1篇
  2014年   4篇
  2013年   24篇
  2009年   1篇
  2005年   1篇
排序方式: 共有43条查询结果,搜索用时 205 毫秒
1.
The behavior of base-isolated building frame is investigated with the help of a numerical study for far-field and near-field earthquakes with directivity and fling-step effects. Both design-level and extreme-level earthquakes are considered. Selected response parameters are peak floor displacement, acceleration, base shear, and isolator displacement. Inelastic behavior of base-isolated structure during the earthquake is investigated performing nonlinear time history analysis of a ten-story building frame. This study shows that base isolation is not effective for near-field earthquakes. Even for design-level earthquake, the frame gets significantly into inelastic range for earthquakes with fling-step effect.  相似文献   
2.
Controlled rocking heavy timber walls are designed to rock on their foundations in response to earthquakes. For regions of moderate seismicity, it is proposed that this rocking behaviour can be adequately controlled using only post-tensioning, even with a large force-reduction factor and no supplemental energy dissipation. This article presents a force-based design procedure for controlled rocking cross-laminated timber walls without supplemental energy dissipation, including a method for estimating higher mode effects. Fragility analyses of three prototype walls demonstrate that the procedure can limit the probability of collapse to <10% during a maximum considered earthquake in a region of moderate seismicity.  相似文献   
3.
It has been pointed out that the static lateral response procedure for base isolated structures presented in IBC somewhat overestimates the seismic story force [Lashkari and Kircher, 1993 Lashkari, B. and Kircher, C. A. . Evaluation of SEAOC/UBC analysis procedures, Part 1: Stiff superstructure. Proceedings of a Seminar on Seismic Isolation, Passive Energy Dissipation and Active Control. Redwood City, California. ATC Report 17-1.  [Google Scholar]; Constantinou et al., 1993 Constantinou, M. C., Winters, C. W. and Theodossiou, D. . Evaluation of SEAOC and UBC analysis procedures, Part 2: Flexible Superstructure. Proceedings of a Seminar on Seismic Isolation, Passive Energy Dissipation and Active Control. Redwood City, California. ATC Report 17-1.  [Google Scholar]]. In this article IBC equivalent static method for base shear distribution of seismic isolated structures is evaluated. For this purpose one-story to six-story building models are designed according to equivalent lateral response procedure for different elastomeric isolation systems. The results of equivalent lateral response procedure in parameters such as base shear and vertical distribution of base shear are compared with results obtained from dynamic nonlinear analysis and the efficiency and limitations of its application are investigated. In general, the results of equivalent lateral response procedure in base shears are acceptable within the scope of this procedure, but the proposed triangular distribution of base shear is somewhat conservative. So a new formulation for vertical distribution of base shear is proposed which results in a more realistic distribution of shear over the height of isolated buildings. The accuracy of the new formulation is examined by comparing the resulting responses obtained from this study with those calculated by nonlinear time history analysis.  相似文献   
4.
The first step in a hysteretic energy-based design approach of performance-based design is the estimation of hysteretic energy demand in the structure. A nonlinear response-history analysis of the multi-degree of freedom model gives an accurate estimation, but it is not suitable for adopting in design. Two alternative methods, based on the concepts of modal pushover analysis (MPA) and 2D-MPA, are proposed in this article for uniaxial plan-asymmetric structures. Application studies show that both methods are efficient. While the 2D-MPA-based method is more accurate, the MPA-based method is more suitable for design adoption. Significant conclusions are given for prospective application of these methods.  相似文献   
5.
Acceleration response of simple yielding structure is proportional to its own weight, but it is limited by yield strength. Thus, using rocking columns that reduces global yield strength, a limited acceleration is achieved. However, the displacement becomes large due to lower strength and higher inelasticity, but it can be controlled by adding damping. Performing fragility analyses, the seismic response of R/C frame structures with rocking columns and viscous dampers is investigated. Near field MCEER ground motions are considered. The analyses show that the story accelerations are reduced by using rocking columns, while the story displacements are controlled by using viscous dampers.  相似文献   
6.
Based on Morison hydrodynamic force theory, a simplified calculation method for hydrodynamic force to slender structures is proposed. A typical cylindrical deep water pile was chosen for study and the simplified method was used to analyze the influence of hydrodynamic pressure on the pile. Then the finite element method was used to study the dynamic characteristics of the model, and the results from both methods were compared. A comparison was also made between the shaking table test on the south tower of the Nanjing Yangtze 3rd River Bridge and the results from the simplified method.  相似文献   
7.
Field ambient vibration tests and modal identification using a Bayesian approach are conducted for a building made of multi-grid composite wall structure and divided into two adjacent parts by a seismic joint, to investigate the dynamic characteristics of the special structural type and the effects of the infilled seismic joint. It is found that dynamic interactions between the two structural parts exist possibly induced by the infill of the building separation. Natural frequencies obtained from other two modal parameter identification methods and modal analysis results of finite element models considering dynamic interactions agree with those identified by the Bayesian approach.  相似文献   
8.
A simple variational formulation for contact dynamics is adopted to investigate the dynamic behavior of planar masonry block structures subjected to seismic events. The numerical model is a two-dimensional assemblage of rigid blocks interacting at potential contact points located at the vertices of the interfaces. A no-tension and associative frictional behavior with infinite compressive strength is considered for joints. The dynamic contact problem is formulated as a quadratic programming problem (QP) and an iterative procedure is implemented for time integration. Applications to analytical and numerical case studies are presented for validation. Comparisons with the experimental results of a masonry wall under free rocking motion and of a small scale panel with opening subjected to in-plane loads are also carried out to evaluate the accuracy and the computational efficiency of the formulation adopted.  相似文献   
9.
The main objective of this paper is to problematize writings on vehicles in an Iranian context. Previous studies have indicated that vehicle stickers can be employed to express emotions and social status, political views, ideology and identity, and religious beliefs. However, very little has been done on this discursive practice in Iran. This study is the result of the content analysis of 122 vehicle writings collected from April 2011 to March 2012. This paper will draw on six of the most frequent themes: religion, humor, playing pessimism, didactic expressions, ethnic-geographic identification, and love. Employing Bourdieu's conceptual frameworks of “habitus,” “field,” and “doxa,” and Heath and Street's social practice perspective on literacy, it will be argued that vehicle writings in this study can be regarded as situated literacy practices reflecting the dominant undisputed discourses in the context, but at the same time displaying the dynamic interplay of power relations, the relationship of cultural structures and individual customized versions of those structures in vehicle writings.  相似文献   
10.
This article presents the results of an exhaustive parametric analysis which compares the performances offered by various systems (which lead to both classical and non classical damping matrices) of added viscous dampers in shear-type structures. The aim of the research work here presented is the identification of the system of added viscous dampers which maximizes the dissipative properties under an equal “total size” constraint. The choice of the systems of added viscous dampers considered in the comparison is carried out both using a numerical approach (based upon the use of genetic algorithms) and a physically based approach (based upon the properties of classically damped systems). The comparison is carried out through the numerical evaluation of the dynamic response of representative shear-type structures to both stochastic and recorded earthquake inputs. The results obtained using both approaches indicate that a damping system based upon the mass proportional damping component of the Rayleigh viscous damping matrix (referred to as MPD system) is capable of optimizing simultaneously a number of different performance indexes, providing the best “overall” damping performances. The MPD system is characterised by viscous dampers (a) which connect each floor to a fixed point and (b) which are sized proportionally to the corresponding floor mass.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号