This article presents an application of microwave reflectometry for the in situ evaluation of timber structures. The measurement system allows detecting anomalies inside the material in a non-destructive and non-invasive manner.
The reflection coefficient is measured by means of a vector network analyzer (VNA) using a double-ridge antenna which transmits the continuous-wave (CW) microwave signal and receives the signal reflected by the material under investigation.
Measurements on laboratory models demonstrated the feasibility of the method. Results obtained on timber beam sections, compared with the findings of traditional investigation methodologies, demonstrate the potentiality of microwave reflectometry, suggesting its possible usefulness during the diagnostic phase as a non-invasive tool for preliminary screening. 相似文献
The effectiveness of the proposed methodology is shown with reference to a complex case study, the historical center of “Montebello di Bertona”. It is initially modeled as a series/parallel system and then studied by applying seismic reliability methods. Seismic retrofitting interventions are finally prioritized. 相似文献