首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   170篇
  免费   3篇
  2022年   1篇
  2021年   1篇
  2020年   4篇
  2019年   12篇
  2018年   19篇
  2017年   2篇
  2016年   1篇
  2015年   2篇
  2014年   13篇
  2013年   82篇
  2012年   6篇
  2011年   5篇
  2009年   4篇
  2008年   3篇
  2007年   4篇
  2006年   1篇
  2005年   2篇
  2004年   1篇
  2003年   1篇
  2002年   2篇
  2001年   2篇
  1999年   1篇
  1997年   1篇
  1996年   1篇
  1993年   1篇
  1991年   1篇
排序方式: 共有173条查询结果,搜索用时 15 毫秒
41.
The 2011 great Japan Tohoku earthquake is not only the most devastating but also, one of the best recorded earthquakes in the history of seismology. A thorough study of strong motion characteristics of this earthquake is conducted using 20 well established ground motion parameters (GMPs). The behaviour of these parameters with fault distance and average shear wave velocity is examined and attenuation relationships are developed using the 1172 surface level strong motion records. In addition, all GMPs are categorized on a statistical basis using principal component analysis, which is further used to rate the damage potential of ground motion records.  相似文献   
42.
This article presents the results of an exhaustive parametric analysis which compares the performances offered by various systems (which lead to both classical and non classical damping matrices) of added viscous dampers in shear-type structures. The aim of the research work here presented is the identification of the system of added viscous dampers which maximizes the dissipative properties under an equal “total size” constraint. The choice of the systems of added viscous dampers considered in the comparison is carried out both using a numerical approach (based upon the use of genetic algorithms) and a physically based approach (based upon the properties of classically damped systems). The comparison is carried out through the numerical evaluation of the dynamic response of representative shear-type structures to both stochastic and recorded earthquake inputs. The results obtained using both approaches indicate that a damping system based upon the mass proportional damping component of the Rayleigh viscous damping matrix (referred to as MPD system) is capable of optimizing simultaneously a number of different performance indexes, providing the best “overall” damping performances. The MPD system is characterised by viscous dampers (a) which connect each floor to a fixed point and (b) which are sized proportionally to the corresponding floor mass.  相似文献   
43.
Issues related to multi-components seismic response analysis are critically reviewed and their implications with respect to the current codified approaches are studied. The issues specifically addressed are: (1) the directions of earthquake forces to excite a structure when the direction of the potential epicenter is known; (2) different commonly used combination rules to obtain the critical response when responses are available in different directions; and (3) the applicability of the combination rules for elastic and inelastic analyses. Based on an extensive parametric study consisting of three-dimensional 1-, 3-, 8-, and 15- story buildings made of moment-resisting steel frames and 20 recorded earthquakes, it is observed that the principal components produce larger responses than the normal components. The 30% and SSRS rules generally underestimate the axial loads in columns. The 30% combination rule is slightly better than the SSRS rule. For both rules, the uncertainty in the estimation of the axial loads in terms of COV is very large (about 25%). The statistics obtained for axial loads and total base shear indicate that the combination rules are applicable for both elastic and inelastic cases. The critical response could be obtained for an orientation different from that of the principal components. The differences are found to be slightly greater for the scaled earthquakes producing a considerable inelastic behavior. Considering the enormous amount of efforts needed to address the directionality effect, it is believed that the responses obtained by the principal components will be acceptable in most cases; however, for critical structures the components should be rotated to obtain the critical responses.  相似文献   
44.
In the present article the effect of subsoil interventions on the response of soil-structure systems under strong earthquake shaking is studied. Several idealized configurations of commonly applied as well as innovative intervention techniques are examined, referring to increased or reduced stiffness of the initial subsoil conditions of the subsoil-foundation-structure system. Numerical analysis utilizing validated simulation procedures covers a large spectrum of structures and soil conditions. A parametric investigation of several key factors is also conducted. A comparative evaluation of the results in time and frequency domain is aiming in generalizing the conclusions to several earthquake and soil-structure combinations. Obtained results reveal a rather detrimental effect of the stiffness-increasing methods, whereas techniques related to modification of oscillation dynamic properties with flexible subsoil intervention schemes, present promising alternatives for an efficient mitigation of structural response to strong earthquakes.  相似文献   
45.
Response of masonry walls to out-of-plane excitation is a complex, yet inadequately addressed theme in seismic analysis. The seismic input expected on an out-of-plane wall (or a generic “secondary system”) in a masonry building is the ground excitation filtered by the in-plane response of the walls and the floor diaphragm response. More generally, the dynamic response of the primary structure, which can be nonlinear, contributes to the filtering phenomenon. The current article delves into the details and results of several nonlinear dynamic time-history analyses executed within a parametric framework. The study addresses masonry structures with rigid diaphragm response to lateral loads. The scope of the parametric study is to demonstrate the influence of inelastic structural response on the seismic response of secondary systems and eventually develop an expression to estimate the seismic input on secondary systems that explicitly accounts for the level of inelasticity in the primary structure in terms of the displacement ductility demand. The proposed formulation is discussed in the companion article.  相似文献   
46.
Using representative numerical models of eight code-designed steel moment-resisting frame buildings and several ground motions, time-history analyses are performed and a critical evaluation of Peak Horizontal Floor Acceleration (PHFA) demands is conducted. The frames are modeled alternatively as linear and nonlinear systems to isolate the effect of building nonlinearity on PHFA. In most cases, PHFA is reduced when nonlinear behavior of a building is considered; however, in some cases, significant amplification of PHFA is observed. Results from the numerical study provide insight into the trend of modal response modification factors presented taking ground motion spectral shape into account.  相似文献   
47.
The seismic response of base-isolated benchmark building with variable sliding isolators like variable friction pendulum system (VFPS), variable frequency pendulum isolator (VFPI), and variable curvature friction pendulum system (VCFPS), along with conventional friction pendulum system (FPS), was studied under the seven earthquakes. The earthquakes are applied bi-directionally in the horizontal plane ignoring vertical ground motion component. The shear type base-isolated benchmark building is modeled as three-dimensional linear elastic structure having three degrees of freedom at each floor level. Time domain dynamic analysis of the benchmark building was carried out with the help of constant average acceleration Newmark-Beta method and nonlinear isolation forces was taken care by fourth-order Runge-Kutta method. The base-isolated benchmark building is investigated for uniform isolation and hybrid isolation in combination with laminated rubber bearings through the performance criteria and time history response of important structural response parameters like floor accelerations, base displacement, etc. It is observed that variable sliding isolators performed better than conventional FPS due to their varying characteristic properties which enable them to alter the isolator forces depending upon their isolator displacements thus improves the performance of the structure. The VFPS efficiently controls large isolator displacements and VFPI and VCFPS improve super structural response on the cost of isolator displacement. It is also observed that the hybrid isolation is relatively better in comparison to the uniform isolation for the benchmark building.  相似文献   
48.
This article is the first of two companion articles that evaluate the seismic performance of steel moment-resisting frames with innovative beam-to-column connections that incorporate shape memory alloys (SMAs) to dissipate energy and provide recentering effectively during large earthquakes. Two types of SMA elements are considered: (1) superelastic SMA elements with recentering capability and (2) martensitic SMA elements with high energy dissipation capacity. This article describes the fundamental engineering characteristics of these SMA connections, their modeling in connections for nonlinear dynamic finite element analysis of building frames, and the validation of these connection models using data from full-scale experimental tests that were performed in previous research at Georgia Institute of Technology. Using three- and nine-story partially restrained (PR) moment frames selected as case studies from the SAC Phase II Project, nonlinear time history analyses of frames with and without SMA connections were conducted using suites of ground acceleration records. The beneficial effects of SMA connections on peak and residual deformation demands are quantified and discussed.  相似文献   
49.
It is numerically illustrated that an unusual overshooting phenomenon might occur in the solution of a forced vibration response if a structure-dependent integration method is applied to conduct the analysis, such as Chang explicit method [2002] and CR explicit method [2008]. This overshooting may occur in the steady-state response of a high frequency mode and it becomes significant as the natural frequency of the mode increases. This unusual overshooting behavior can be successfully detected by using a local truncation error derived from a forced vibration response rather than a free vibration response. A missing loading term in the difference equation for displacement increment is responsible for this unusual overshoot. It is analytically and numerically verified that the unusual overshooting behavior will automatically disappear after introducing the missing loading term into the difference equation for displacement increment.  相似文献   
50.
The seismic response of bridges is affected by a number of modeling considerations, such as pier embedment, buried pile caps, seat-type abutments, pounding, bond slip and architecturally flared part of piers, and loading considerations, such as non-uniform ground excitations and orientation of ground motion components, which are not readily addressed by design codes. This article addresses a methodology for the nonlinear static and dynamic analysis of a tall, long-span, curved, reinforced-concrete bridge, the Mogollon Rim Viaduct. Various modeling scenarios are considered for the bridge components, soil-structure interaction system, and materials, i.e., concrete and reinforcing steel, covering all its geotechnical and structural aspects based on recent advances in bridge engineering. Various analysis methodologies (nonlinear static pushover, time history response to uniform and spatially variable seismic excitations, and incremental dynamic analyses) are performed. For the dynamic analyses, a suite of nine earthquake accelerograms are selected and their characteristics are investigated using seismic intensity parameters. A recently developed approach for the generation of non-uniform seismic excitations, i.e., spatially variable simulations conditioned on the recorded time series, is used. Methods for the evaluation of structural performance are discussed and their limitations addressed. The numerical results of the seismic assessment of the Mogollon Rim Viaduct are presented in the companion article (Part II). The sensitivity of the bridge response to the adopted modeling, loading and analyzing strategies, as well as the correlation between structural damage and seismic intensity parameters are examined in detail.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏