A complete structural analysis of the bell tower of Santa Maria del Carmine in Naples (Italy) has been developed by using a 3D FE model based on the results of detailed experimental investigations in situ. Linear analysis for gravity loads, linear modal analysis, and nonlinear static analysis (Push Over) were carried out in order to assess the seismic capacity of the structure. A check of local out-of-plane failure mechanisms was also performed to verify if the structure is able to attain a global behavior. Problems and solutions related to the different methods are presented and discussed.  相似文献   
12.
A methodology is presented for assessing the seismic vulnerability of inventories of contents to multiple failure modes. An ordering method to find out probabilities of failure of a conditional mode upon the survival of the other modes is applied. The procedure considers the statistical correlation of failure modes due to the dynamic response, such as sliding and/or overturning, of contents and also to non structural components. This methodology was applied to inventories of four types of occupancy (house, school, office, and hospital) located in Mexico City, considering that all contents are situated at ground level. Expected damage functions for these inventories show large differences between them, the house and school inventories being the least vulnerable, and the hospital inventory, the most vulnerable, even for low intensities.  相似文献   
13.
Abstract

This paper is related to historic buildings and sites which represent a physical cultural environment most tangibly and also represent a majority of all the listed cultural heritage in all countries. The paper is particularly concerned with various techniques of recording information about the built heritage. This is commonly regarded as a one‐off record by field observation, but the author makes a case for recording to be a continuous process. Recording is not simply the first activity in the historic preservation process but an integral part of all phases. Despite the difficulty of defining objectives and evaluating results experience with the built heritage of the Czech Republic suggests that recording should be an on‐going, flexible and integral part of the conservation process. It is best carried out largely by recorders working within the Conservation Office.  相似文献   
14.
The publication of Part 3 of Eurocode 8 (EC8-3), dedicated to the seismic assessment of existing buildings, took place a decade ago. However, its application in engineering practice has been limited. Moreover, no studies have been conducted regarding the application of EC8-3 to steel structures. In this paper, a critical review and practical application of EC8-3 and ASCE41-13 are carried out. Issues related to the definition of the performance requirements, compliance criteria, and the consistency of the analysis procedures proposed by both standards are identified. Conceptual differences between both documents are highlighted, and several inconsistencies in EC8-3 are discussed.  相似文献   
15.
This paper first critically reviews a seismological model and then a three-segment curve model (in log-log space) to model the Q-f relationship is proposed to overcome the potential biased estimation in the long-period range by the “coda wave” method. The optimal curve-fitting process is performed to determine the Q-f relationship for the Hong Kong region. The calibrated seismological factors are incorporated with the stochastic simulation procedure to generate synthetic ground motions, which are validated through comparison with seismic records. The impact of long-period ground motions on the seismic response of high-rise buildings is finally manifested through a numerical study.  相似文献   
16.
Experimental tests on four full-scale exterior unreinforced reinforced concrete (RC) beam-column joints, representative of the existing non-conforming RC frame buildings, are carried out. The specimens have different longitudinal reinforcements (plain or deformed) and they are designed in order to be representative of two typical design practices (for gravity loads only or according to an obsolete seismic code). Different failure modes are observed, namely joint failure with or without beam yielding. The local response of the joint panel is analyzed. The different joint deformation mechanisms and their contribution to the deformability and to the energy dissipation capacity of the sub-assemblages are evaluated.  相似文献   
17.
In this article, a number of design approaches for 3D reinforced concrete (RC) buildings are formulated in the framework of structural optimization problems and are assessed in terms of their performance under earthquake loading. In particular, three design approaches for RC buildings are considered in this study. In the first, the initial construction cost is considered as the objective function to be minimized. The second one is formulated as a minimization problem of the torsional response, while a combined formulation is also examined as the third design approach. The third approach is considered with two distinctive formulations. According to the first approach, the torsional behavior is minimized by minimizing the eccentricity between the mass and rigidity centers, while the second one is achieved by minimizing the eccentricity between the mass and strength centers. It is shown that the optimized designs obtained according to the minimum eccentricity of the rigidity center behave better in frequent (50/50 hazard level) and occasional (10/50 hazard level) earthquakes, while the designs obtained according to the minimum eccentricity of the strength center formulation was found better in rare (2/50 hazard level) events. Designs obtained through a combined formulation seem to behave equally well in the three hazard levels examined.  相似文献   
18.
A simple stick model is presented for the inelastic seismic analysis in 3D of two-way eccentric multistory RC buildings. It has 3 DoFs per floor, point hinges at the ends of the vertical elements connecting floors, elastic story stiffness derived from the corresponding story force-interstory deformation relations of the elastic 3D structure under inverted-triangular floor loading (by torques for torsional stiffness, by horizontal forces for the lateral ones), story yield forces derived from the total resistant shear of the story vertical elements, but no coupling between lateral and torsional inelasticity. It is evaluated on the basis of comparisons of response histories of floor displacements to those from full nonlinear models in 3D of four actual buildings. Alternative locations of the story vertical element with respect to the floor mass center are examined: (a) the floor “center of twist” of the elastic 3D building under inverted-triangular floor torques; (b) the story “effective center of rigidity,” through which application of inverted triangular lateral forces does not induce twisting of floors; (c) the centroid of the secant stiffness of the story vertical members at yielding and (d) the centroid of the lateral force resistance of story vertical elements. Among alternatives (a)–(d), the floor “center of twist” provides the best agreement with floor displacement response-histories from full 3D nonlinear models. This means that the static eccentricity that matters for torsional response may be taken as that of the floor “center of twist.” The center of resistance comes up as the second-best choice.  相似文献   
19.
This study investigates the effectiveness of the modal analysis using three-degree-of freedom (3DOF) modal equations of motion to deal with the seismic analysis of two-way asymmetric elastic systems with supplemental damping. The 3DOF modal equations of motion possessing the non proportional damping property enable the two modal translations and one modal rotation to be non proportional in an elastic state. The simple approximation method is to use the single degree-of-freedom (SDOF) modal equations of motion, which are obtained by neglecting the off-diagonal elements of the transformed damping matrix. One, one-story and one, three-story non proportionally damped two-way asymmetric buildings under the excitation of bi-directional seismic ground motions are analyzed. The analytical results are obtained by using the proposed method, noted simple approximation method, and direct integration of the equation of motion. It is seen that the proposed method can significantly improve the accuracy of the analytical results compared with those obtained by using the simple approximation method. Moreover, the proposed method does not substantially increase the computational efforts.  相似文献   
20.
An experimental investigation of an exterior waffle flat plate-column connection subjected to combined gravity and cyclic lateral loading is presented. The test model was designed according to construction practices used over ten years ago in the Mediterranean area. Test results are discussed in conjunction with previous studies on flat-slab connections and ACI 318–05 code idealizations. The specimen exhibited a “strong column-weak plate” mechanism, whose behavior was controlled by the torsion cracks. First yielding and failure occurred at 1% and 5.5% drift-ratios, respectively. The results show that ACI 318–05 code significantly underestimates strength; as an alternative, a simple model is proposed.  相似文献   