首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
ABSTRACT

Although many experimental tests and numerical models are available in the literature, the numerical simulation of the seismic response of existing masonry buildings is still a challenging problem. While the nonlinear behavior of masonry structures is reasonably predictable when the out-of-plane behavior can be considered inhibited, when the in-plane and out-of-plane responses coexist and interact, simplified models seem unable to provide reliable numerical predictions. In this article, taking advantage of the experimental tests carried out in a shaking table on two masonry prototypes at LNEC, a macro-element approach is applied for the numerical simulations of their nonlinear response. The adopted approach allows simulating the nonlinear behavior of masonry structures considering the in-plane and out-of-plane responses. Since it is based on a simple mechanical scheme, explicitly oriented to representing the main failure mechanisms of masonry, its computational cost is greatly reduced with respect to rigorous solutions, namely nonlinear FEM approaches. Two modeling strategies are adopted, namely a regular mesh independent from the real texture of the prototypes and a detailed one coherent with the units disposal. The numerical results are discussed and the correlation between the nonlinear static analyses and the dynamic response is provided.  相似文献   

2.
ABSTRACT

An experimental campaign and a numerical analysis devoted to the investigation of the out-of-plane behavior of masonry walls reinforced with Fiber Reinforced Cementitious Matrix (FRCM) are presented here. The main goal of this study is to analyze and evaluate the effectiveness of the strengthening system, by discussing failure modes and capacity of strengthened masonry walls, in order to assess their behavior under out-of-plane horizontal actions, such as, for example, seismic actions. A purposely designed experimental set-up, able to separately and independently apply an axial force and out-of-plane horizontal actions on masonry walls, was used. Experimental results are discussed and compared with the outcomes of nonlinear analyses performed on simplified finite element models of the walls. A proper evaluation of the flexural capacity of FRCM strengthened walls is the first step of the ongoing process of drawing reliable code guidelines leading to a safe design of strengthened masonry structures.  相似文献   

3.
ABSTRACT

This article presents numerical simulations of two full-scale masonry structures which were tested on the shaking table within the scope of the workshop “Methods and challenges on the out-of-plane assessment of existing masonry buildings”. The numerical models have been developed on the basis of the blind-prediction models which have been improved after the publication of the test results. The solution procedure is divided into two steps with separate numerical simulations for each one. In the first step the collapse mechanism of the structure is determined by means of pushover analysis using a continuum, plasticity-based model. In the second step the dynamic response of the structure is simulated using a multibody model approach and frictional contacts. Results of the tests show reasonable, yet far from perfect predictive capabilities of the used numerical methods.  相似文献   

4.
ABSTRACT

Earthquakes cause severe damage to masonry structures due to inertial forces acting in the normal direction to the plane of the walls. The out-of-plane behavior of masonry walls is complex and depends on several parameters, such as material and geometric properties of walls, connections between structural elements, the characteristics of the input motions, among others. Different analytical methods and advanced numerical modeling are usually used for evaluating the out-of-plane behavior of masonry structures. Furthermore, different types of structural analysis can be adopted for this complex behavior, such as limit analysis, pushover, or nonlinear dynamic analysis.

Aiming to evaluate the capabilities of different approaches to similar problems, blind predictions were made using different approaches. For this purpose, two idealized structures were tested on a shaking table and several experts on masonry structures were invited to present blind predictions on the response of the structures, aiming at evaluating the available tools for the out-of-plane assessment of masonry structures. This article presents the results of the blind test predictions and the comparison with the experimental results, namely in terms of formed collapsed mechanisms and control outputs (PGA or maximum displacements), taking into account the selected tools to perform the analysis.  相似文献   

5.
ABSTRACT

Kinetic analysis methods based on linear and nonlinear rigid body dynamics are used to evaluate earthquake safety of masonry structures. In this study, the formulas used to calculate the in-plane and out-of-plane load capacities of masonry load-bearing walls were evaluated and a procedure based on rigid body mechanism was proposed to calculate the out-of-plane load capacities of the walls of Ottoman period masonry mosques. New aspects of the method with respect to existing formulations is the inclusion of dynamic axial load and definition of the collapse limit spectral acceleration on the overturning wall. The calculated capacities of the mosque and individual walls were compared with the results of nonlinear pushover analysis and time history analyses performed under 1.0 and 0.5 scaled forms of nine different 3-component ground motion records. It was displayed that the seismic load capacity estimated by the proposed method is very close to the values calculated by pushover and time history analyses. The method was developed on Lala Pasha Mosque, and the reliability and applicability of the proposed methodology is verified on a different historical masonry mosque in comparison to finite element analyses results.  相似文献   

6.
ABSTRACT

Historical centers are always composed of masonry building aggregates often designed without respecting seismic design criteria. The current seismic Italian code does not foresee a clear calculation method to predict their static nonlinear behavior. For this reason, in this article the seismic response of structural units into masonry aggregates has been predicted through a simplified modeling approach. The implemented procedure has been calibrated on the results of a numerical model performed by using the Equivalent Frame Method (EFM), implemented within a Finite Element Method (FEM) calculation program, used to investigate a basic building compound representative of the constructive techniques developed in the past decades in the Southern Italy.

First, the whole aggregate has been modeled and analyzed in the nonlinear static field in order to evaluate the seismic behavior of both intermediate and head structural units.

Later on, the seismic response of these structural units, considered as isolated structures, has been assessed by considering in simplified way their position in the aggregate, as well as the influence of other constructions.

Finally, the achieved results on the above single analysis cases have been compared with those deriving from the investigation of the whole building compound, allowing to confirm the effectiveness of the proposed novel analysis procedure.  相似文献   

7.
ABSTRACT

The vulnerability of masonry infills within reinforced concrete (rc) frames under out-of-plane loading induced by earthquakes has been observed in several past earthquakes through severe damage and often total collapse. Although the infill panels are assumed as non-structural elements, their damage or collapse is not desirable, given the possible consequences in terms of human life losses and repair or reconstruction costs.

Therefore, it is important to gather better insight on the out-of-plane behavior of existing infills so that strengthening guidelines can be derived. In this scope, the main objective of this study is to analyze the out-of-plane experimental behavior of masonry infilled frames that are characteristic of Portuguese buildings and can be seen in other south European countries. In the experimental study carried out, different parameters affecting the out-of-plane response of infilled frames were considered, namely, workmanship, existence of openings and prior in-plane damage. The experimental program was designed to test six half-scale specimens. The out-of-plane loading was applied uniformly to the brick infills by means of an airbag to simulate the effect of earthquakes.  相似文献   

8.
Much research in recent years has focused on the seismic analysis of concrete and earthfill dams, and few works have addressed the case of masonry dams. The structural behavior of masonry dams is controlled essentially by its discontinuous nature, which may induce significant nonlinear response during an intense earthquake. In this article, a numerical tool based on the Discrete Element Method is presented, aimed at the static, dynamic, and hydromechanical analysis of masonry gravity dams. The use of discontinuous models is mandatory for the study of failure mechanisms involving the masonry discontinuities, the dam-rock interface or the rock mass joints. The Discrete Element Method is able to assemble continuous and discontinuous meshes simultaneously in the same model, providing a versatile tool to consider various assumptions and levels of analysis, ranging from simplified to detailed structural representations. A comprehensive study of the seismic behavior of Lagoa Comprida Dam, located in Portugal, is presented. Both continuous and discontinuous models were developed to assess the main failure mechanisms, including overstress, partial and global sliding, and overturning.  相似文献   

9.
Seismic vulnerability of unreinforced masonry buildings is studied by means of simplified out-of-plane collapse mechanisms that take into account connections with transversal walls. According to experimental evidence, the analysis assumes that failure is reached with a rigid body motion of a part of the facade that falls down. Two classes of mechanism are examined: the overturning of the facade due either to a vertical crack at the connection or a diagonal crack on the transversal wall, both defined resorting to a simple model of masonry fabric, viewed as a regular assembly of rigid blocks and elastic plastic joints with friction but no cohesion. The use of simplified mechanisms give rise to an explicit evaluation of the seismic resistance to changes in the geometry and in the masonry fabrics, that could be used by practising engineers. This formulation is developed for both static horizontal actions and ground velocity peak, in the belief that the latter probably gives a better approximation of seismic action, while also providing, by comparison with the results of static forces, an estimate of the behaviour factor for unreinforced masonry. Eventually, the analytical forecasts are compared with numerical results obtained by means of the distinct element method.  相似文献   

10.
ABSTRACT

Modeling unreinforced masonry walls, subjected to seismic loads applied normal to their plane, has received much attention in the past. Yet, there is a general lack of conformance with regard to what aspects of seismic response a computational model should reflect. Boundary conditions are certainly an important aspect, as the response can involve two-way bending or just one-way bending and, in the second case, along vertical or horizontal directions. In this respect, flexural restraint of wall intersections can be significant in addition to size and placement of openings. Moreover, in-plane damage can modify the boundary conditions and the overall out-of-plane performance. Proper modeling of actions is also relevant, as they can be a result of distortions imposed upon wall elements and/or inertial forces along the span of a wall. Axial forces can markedly affect the out-of-plane response of the wall, particularly vertical compressive forces, which can enhance out-of-plane strength. The outcome of static verifications can be more conservative than that of dynamic analyses, but the latter are much more complex to carry out. These topics are discussed with reference to previous research, observations in the field and in the laboratory, as well as numerical analyses on three-dimensional models.  相似文献   

11.
ABSTRACT

The paper analyzes the static behavior and the seismic vulnerability of the “San Francesco ad Alto” building in Ancona (Italy), which is currently used as a Regional Headquarter of the Marche Region by the Italian Army and was formerly a monastery. The global static structural behavior and the dynamic properties have been evaluated using the Finite Element modeling technique, in which the nonlinear behavior of masonry has been taken into account by proper constitutive laws. The concepts of homogenized material and smeared cracking are used to evaluate the capacity of the monastery to withstand lateral loads together with the expected demands resulting from seismic actions (N2 method), using a nonlinear static analysis (pushover). The comparison of seismic demand and capacity confirms the susceptibility of these types of buildings to extensive damage and collapse, as frequently observed in similar buildings. This paper aims to point out that advanced numerical analyses can offer significant information on the understanding of the actual structural behavior of historical buildings. It is believed that the methodology and the overall conclusions of this case study are valid for many historical monasteries in Europe.  相似文献   

12.
This article describes a simplified procedure for estimating the seismic sidesway collapse capacity of frame building structures incorporating linear viscous dampers. The proposed procedure is based on a robust database of seismic peak displacement responses of viscously damped nonlinear single-degree-of-freedom systems for various seismic intensities and uses nonlinear static (pushover) analysis without the need for nonlinear time history dynamic analysis. The proposed procedure is assessed by comparing its collapse capacity predictions on 272 different building models with those obtained from incremental dynamic analyses. A straightforward collapse capacity-based design procedure is also introduced for structures without extreme soft story irregularities.  相似文献   

13.
ABSTRACT

Traditional domes are obtained by double curvature shells, which can be rotationally formed by any curved geometrical plane figure rotating about a central vertical axis. They are self-supported and stabilized by the force of gravity acting on their weight to hold them in compression. However, the behavior of inverted domes is different since the dome is downward and masonry inverted domes and their structural behaviors in the literature received limited attention. This article presents a nonlinear finite element analysis of historical brick masonry inverted domes under static and seismic loads. The brick masonry inverted dome in the tomb of scholar Ahmed-El Cezeri, town of Cizre, Turkey, constructed in 1508 is selected as an application. First, a detailed literature review on the masonry domes is given and the selected inverted dome is described briefly. 3D solid and continuum finite element models of the inverted masonry dome are obtained from the surveys. An isotropic Concrete Damage Plasticity (CDP) material model adjusted to masonry structures with the same tensile strength assumed along the parallel and meridian directions of the inverted dome is considered. The nonlinear static analyses and a parametric study by changing the mechanical properties of the brick unit of the inverted masonry dome are performed under gravity loads. The acceleration records of vertical and horizontal components of May 1, 2003 Bingöl earthquake (Mw = 6.4), Turkey, occurred near the region, are chosen for the nonlinear seismic analyses. Nonlinear step by step seismic analyses of the inverted dome are implemented under the vertical and horizontal components of the earthquake, separately. Static modal and seismic responses of the inverted masonry dome are evaluated using mode shapes, minimum and maximum principal strains and stresses, and damage propagations.  相似文献   

14.
Response of masonry walls to out-of-plane excitation is a complex, yet inadequately addressed theme in seismic analysis. The seismic input expected on an out-of-plane wall (or a generic “secondary system”) in a masonry building is the ground excitation filtered by the in-plane response of the walls and the floor diaphragm response. More generally, the dynamic response of the primary structure, which can be nonlinear, contributes to the filtering phenomenon. The current article delves into the details and results of several nonlinear dynamic time-history analyses executed within a parametric framework. The study addresses masonry structures with rigid diaphragm response to lateral loads. The scope of the parametric study is to demonstrate the influence of inelastic structural response on the seismic response of secondary systems and eventually develop an expression to estimate the seismic input on secondary systems that explicitly accounts for the level of inelasticity in the primary structure in terms of the displacement ductility demand. The proposed formulation is discussed in the companion article.  相似文献   

15.
Considering the likely unfavorable behavior under seismic action of adobe construction, this article aims at providing a seismic fragility characterization of two adobe Portuguese traditional buildings, using numerical models calibrated over experimental results. The study of such two case-study buildings in the region of Aveiro contributes to the understanding of the seismic fragility of adobe construction in the region in general. The buildings were numerically modeled to estimate their structural behavior under seismic loading using adobe material properties that were calibrated based on the experimental results of a cyclic in-plane test of a full-scale double-Tshaped adobe wall. The method chosen to characterize adobe masonry and model its nonlinear behavior followed a total strain crack-based macro-modeling (TSCM) approach, whereas pushover analysis was carried out to reproduce the pseudo-static experimental test in order to enable a refined calibration of adobe masonry mechanical properties. Fragility functions were then derived, based on the above-mentioned numerical models, using nonlinear static analysis, bringing further insight on the seismic fragility of traditional Portuguese adobe construction.  相似文献   

16.
ABSTRACT

Despite the high vulnerability of historic structures to earthquakes, the approaches for evaluating seismic demand and capacity still appear inadequate and there is little consensus on the most appropriate assessment methods to use. To develop an improved knowledge on the seismic behavior of masonry structures and the reliability of analysis tools, two real-scale specimens were tested on a shake table, and several experts were invited to foresee failure mechanism and seismic capacity within a blind prediction test. Once unveiled, experimental results were simulated using multi-block dynamics, finite elements, or discrete elements. This article gathers the lessons learned and identifies issues requiring further attention. A combination of engineering judgment and numerical models may help to identify the collapse mechanism, which is as essential as it is challenging for the seismic assessment. To this purpose, discrete modeling approaches may lead to more reliable results than continuous ones. Even when the correct mechanism is identified, estimating the seismic capacity remains difficult, due to the complexity and randomness of the seismic response, and to the sensitivity of numerical tools to input variables. Simplified approaches based on rigid body dynamics, despite the considerable experience and engineering judgment required, provide as good results as do advanced simulations.  相似文献   

17.
Although the issue of the out-of-plane response of unreinforced masonry structures under earthquake excitation is well known with consensus among the research community, this issue is simultaneously one of the more complex and most neglected areas on the seismic assessment of existing buildings. Nonetheless, its characterization should be found on the solid knowledge of the phenomenon and on the complete understanding of methodologies currently used to describe it. Based on this assumption, this article presents a general framework on the issue of the out-of-plane performance of unreinforced masonry structures, beginning with a brief introduction to the topic, followed by a compact state of art in which the principal methodologies proposed to assess the out-of-plane behavior of unreinforced masonry structures are presented. Different analytical approaches are presented, namely force and displacement-based, complemented with the presentation of existing numerical tools for the purpose presented above. Moreover, the most relevant experimental campaigns carried out in order to reproduce the phenomenon are reviewed and briefly discussed.  相似文献   

18.
ABSTRACT

Historical masonry structures are often located in earthquake-prone regions and the majority of them are considered to be seismically vulnerable and unsafe. Historical masonry towers are slender structures that exhibit unique architectural features and may present many inadequacies in terms of seismic performance. The seismic protection of such typologies of structures and the design of effective retrofitting interventions require a deep understanding of their behavior under horizontal loads. This paper presents the results of the seismic performance evaluation of historical masonry towers located in Northern Italy. A large set of case studies is considered, comprising a significant number of towers with high slenderness and marked inclination. First, a preliminary assessment of the dynamic behavior of the different towers is carried out through eigenfrequency analyses. Then, non-linear dynamic simulations are performed using a real accelerogram with different peak ground accelerations. A damage plasticity material model, exhibiting softening in both tension and compression, is adopted for masonry. The huge amount of results obtained from the non-linear dynamic simulations allows a comparative analysis of the towers to be performed in order to assess their seismic vulnerability and to show the dependence of their structural behavior on some geometrical characteristics, such as slenderness, inclination, and presence of openings and belfry. The evaluation of different response parameters and the examination of tensile damage distributions show the high vulnerability of historical masonry towers under horizontal loads, mainly in the presence of marked inclination and high slenderness. Some general trends of the seismic behavior of the towers are deduced as a function of the main typological features.  相似文献   

19.
ABSTRACT

Observations after strong earthquakes show that out-of-plane failure of unreinforced masonry elements probably constitutes the most serious life-safety hazard for this type of construction. Existing unreinforced masonry buildings tend to be more vulnerable than new buildings, not only because they have been designed to little or no seismic loading requirements, but also because connections among load-bearing walls and with horizontal structures are not always adequate. Consequently, several types of mechanisms can be activated due to separation from the rest of the construction. Even when connections are effective, out-of-plane failure can be induced by excessive vertical and/or horizontal slenderness of walls (length/thickness ratio). The awareness of such vulnerability has encouraged research in the field, which is summarized in this article. An outline of past research on force-based and displacement-based assessment is given and their translation into international codes is summarized. Strong and weak points of codified assessment procedures are presented through a comparison with parametric nonlinear dynamic analyses of three recurring out-of-plane mechanisms. The assessment strategies are marked by substantial scatter, which can be reduced through an energy-based assessment.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号