 共查询到20条相似文献,搜索用时 15 毫秒
1.
Two concrete frames were tested by the PsD procedure. One frame was bare and the other was infilled with AAC blocks in the middle bay. The objective was to determine the effect of AAC infills on the seismic performance of reinforced concrete frames and developing an AAC strut model. Based on the test results, it was found that AAC infill panels did not modify the deformation response of the RC test frame significantly; however, shear in diagonal strut must be considered in boundary column design. A shear design procedure is proposed for the boundary columns in infilled frames. The drift limits of AAC infill panels measured during the tests were 0.005, 0.008, and 0.014 during diagonal cracking, corner crushing, and severe damage states, respectively.  相似文献   

2.
ABSTRACT

The vulnerability of masonry infills within reinforced concrete (rc) frames under out-of-plane loading induced by earthquakes has been observed in several past earthquakes through severe damage and often total collapse. Although the infill panels are assumed as non-structural elements, their damage or collapse is not desirable, given the possible consequences in terms of human life losses and repair or reconstruction costs.

Therefore, it is important to gather better insight on the out-of-plane behavior of existing infills so that strengthening guidelines can be derived. In this scope, the main objective of this study is to analyze the out-of-plane experimental behavior of masonry infilled frames that are characteristic of Portuguese buildings and can be seen in other south European countries. In the experimental study carried out, different parameters affecting the out-of-plane response of infilled frames were considered, namely, workmanship, existence of openings and prior in-plane damage. The experimental program was designed to test six half-scale specimens. The out-of-plane loading was applied uniformly to the brick infills by means of an airbag to simulate the effect of earthquakes.  相似文献   

3.
This article investigates the seismic behavior of masonry infilled RC frames with/without openings. Four full-scale, single-story, and single-bay specimens were tested under constant vertical loads and quasi-static cyclic lateral loads. The experimental results showed that the infill wall was more influential in stiffness than in load-resisting capacity. The opening increased the ductility ratio of the structure due to the uniform distribution and slow propagation of cracks. Finally, simplified micro finite element models are established to simulate the tested specimens, which effectively predict the load-displacement response of the structures and the crack damage of masonry infill wall with acceptable accuracy.  相似文献   

4.
This article presents an experimental investigation of the seismic performance of gravity load-designed RC infilled frames and confined bearing walls of limestone masonry backed with plain concrete. Five infilled frames and two bearing walls were constructed at one-third scale and tested using reversed cyclic lateral loading and constant axial loads. Effects of openings, axial loading, and infill interface conditions were examined using quasi-static experimentation. The two structural systems exhibited similar lateral resistance and energy dissipation capacities with higher global displacement ductility for the infilled frames. Hysteretic behavior of the infilled frame models exhibited pinching of the hysteretic loops accompanied by extensive degradation of stiffness whereas loops of the bearing walls were free of pinching. Test results confirmed the beneficial effect of axial loading on lateral resistance, energy dissipation, and ductility of the bearing walls. Higher axial loading resulted in a substantial decrease in ductility with no significant effect on lateral resistance of the infilled frames. Openings within the infill panel reduced significantly the lateral resistance of infilled frames. Using dowels at the infill panel interfaces with the base block and bounding columns enhanced the maximum load-carrying capacity of infilled frames without impairing their ductility.  相似文献   

5.
In this article, seismic vulnerability assessment is carried-out on a novel hybrid structure (steel moment resisting frame (SMRF) and cross laminated timber (CLT) infill panels). For the seismicity of Vancouver, Canada, a three-bay, 3-, 6-, and 9-story height SMRFs are designed for two ductility levels (ductile and limited ductility). To study the seismic vulnerability CLT infilled building, parametric analysis was performed by varying infill configuration (bare frame, one-bay infilled, two-bay infilled, and fully infilled). The structure is modeled in OpenSees and nonlinear dynamic analysis is performed. Peak inter-story drift demand and corresponding FEMA performance limits (capacity) values are used to compute the corresponding fragility curves. From the analyses, it can be seen that as more bays are infilled, the fundamental period and seismic vulnerability is reduced significantly. The results highlight that, within the performance-based earthquake engineering, different objectives can be met with varying the CLT configuration.  相似文献   

6.
The influence of masonry infills with openings on the seismic performance of reinforced concrete (R/C) frames that were designed in accordance with modern codes provisions is investigated. Two types of masonry infills were considered that had different compressive strength but almost identical shear strength. Infills were designed so that the lateral cracking load of the solid infill is less than the available column shear resistance. Seven 1/3 – scale, single–story, single–bay frame specimens were tested under cyclic horizontal loading up to a drift level of 40%. The parameters investigated are the opening shape and the infill compressive strength. The assessment of the behavior of the frames is presented in terms of failure modes, strength, stiffness, ductility, energy dissipation capacity, and degradation from cycling. The experimental results indicate that infills with openings can significantly improve the performance of RC frames. Further, as expected, specimens with strong infills exhibited better performance than those with weak infills. For the prediction of the lateral resistance of the studied single-bay, single-story infilled frames with openings, a special plastic analysis method has been employed.  相似文献   

7.
The effects of masonry infills on the global seismic response of reinforced concrete structures is studied through numerical analyses. Response spectra of elastic SDOF frames with nonlinear infills show that, despite their apparent stiffening effect on the system, infills reduce spectral displacements and forces mainly through their high damping in the first large post-cracking excursion. Parametric analyses on a large variety of multi-storey infilled reinforced concrete structures show that, due to the hysteretic energy dissipation in the infills, if the infilling is uniform in all storeys, drifts and structural damage are dramatically reduced, without an increase in the seismic force demands. Soft-storey effects due to the absence of infills in the bottom storey are not so important for seismic motions at the design intensity, but may be very large at higher motion intensities, if the ultimate strength of the infills amounts to a large percentage of the building weight. The Eurocode 8 provisions for designing the weak storey elements against the effects of infill irregularity are found to be quite effective, in general, for the columns, but unnecessary and often counterproductive for the beams.  相似文献   

8.
The aim of this study was to propose an extension of the displacement-based assessment procedure for infilled reinforced concrete (RC) frames. Two fundamental steps of the displacement-based approach were studied: the determination of the equivalent viscous damping and the definition of the limit-state displacement profile. The proposed criteria were derived by examining the results of two different numerical investigations regarding the nonlinear seismic response of single- and multi-story infilled RC frames. Lastly, the effectiveness of the method was verified through comparisons, in terms of displacement demand, with the results of nonlinear dynamic analyses.  相似文献   

9.
The results of a parametric study are presented, concerned with the evaluation of the structural overstrength, the global ductility and the available behaviour factor of existing reinforced concrete (RC) buildings designed and constructed according to past generations of earthquake resistant design codes in Greece. For the estimation of these parameters, various failure criteria are incorporated in a methodology established to predict the failure mode of such buildings under planar response, as described in detail in a companion publication. A collection of 85 typical building forms is considered. The influence of various parameters is examined, such as the geometry of the structure (number of storeys, bay width etc.), the vertical irregularity, the contribution of the perimeter frame masonry infill walls, the period of construction, the design code and the seismic zone coefficient. The results from inelastic pushover analyses indicate that existing RC buildings exhibit higher overstrength than their contemporary counterparts, but with much reduced ductility capacity. The presence of perimeter infill walls increases considerably their stiffness and lateral resistance, while further reducing their ductility. Fully infilled frames exhibit generally good behaviour, while structures with an open floor exhibit the worst performance by creating a soft storey. Shear failure becomes critical in the buildings with partial height infills. It is also critical for buildings with isolated shear wall cores at the elevator shaft. Out of five different forms of irregularity considered in this study, buildings with column discontinuities in the ground storey exhibit the worst performance. Furthermore, buildings located in the higher seismicity zone are more vulnerable, since the increase of their lateral resistance and ductility capacity is disproportional to the increase in seismic demand.  相似文献   

10.
On September 7, 1999 an earthquake with magnitude M W =5.9 occurred close to the city of Athens in Greece. More than 80 buildings collapsed, about 150 deaths and hundreds of injuries were reported. Soon after the event a damage investigation was carried out by two of the authors in the most heavily struck areas. The most serious damages were observed in the northern suburbs of Athens, where reinforced concrete frames and masonry buildings represent the prevalent construction systems. The hysteretic energy demands imposed on RC buildings should have been rather severe considering the structural systems characteristics and the inadequate construction details. However, over-strengths, redundancy and especially the presence of infill walls, provided a significant increase of the seismic capacity and contributed to the survival of many buildings.

The objective of the present work is to reproduce and analyse the response of typical RC frames subjected to the 1999 Athens earthquake in areas where the observed damage was particularly severe but no recordings of the ground motion were available. After a general overview of the seismotectonic environment, seismological data, observed macro-seismic intensities, structural typologies and observed building behaviour, an attempt is made to identify representative excitations in the meizoseismal area. Specifically, the required accelerograms are obtained by modifying available records so as to reproduce a given global energy content and to be consistent with the observed damage. To study the seismic response of RC models, the obtained accelerograms are used to perform nonlinear dynamic analyses.  相似文献   

11.
Different relations have been represented for the local damage index of structures to date, while the same application is defined for them as can be an indicator of relative sustained damage by the components or stories. Since different force-resisting systems subjected to the ground motions can behave differently, some well-known story damage indices are evaluated for the reinforced concrete frames with regards to their operation during nonlinear time history analysis. Two general concepts of story damage determination are selected for this purpose. SDI is a modal-based story damage index, which is calculated by the modal frequency and mode shapes. The behavior of this local index is evaluated during the seismic excitations. The results were compared with Park-Ang and modal flexibility story damage indices. Based on analytical study on seismic responses of some RC frames subjected to a suit of earthquake records a new story damage index has been developed. It has been derived from a simple global damage equation (softening index) using a normalized ratio of inelastic story shear to its drift. A procedure is recommended to use the proposed equation without any requirement to perform nonlinear dynamic analysis, which can significantly reduce the computational efforts. Distribution of the new represented SDI along the structural height shows a good agreement with damaged state of the RC frames after seismic excitations.  相似文献   

12.
In this paper, the damage prediction of shear-dominated reinforced concrete (RC) elements subjected to reversed cyclic shear is presented using an existing damage model. The damage model is primarily based on the monotonic energy dissipating capacity of structural elements before and after the application of reversed cyclic loading. Therefore, it could be universally applicable to different types of structural members, includeing shear-dominated RC members. The applicability of the damage model to shear-dominated RC members is assessed using the results from reversed cyclic shear load tests conducted earlier on eleven RC panels. First, the monotonic energy dissipating capacities of the panels before and after the application of reversed cyclic loading are estimated and employed in the damage model. Next, a detailed comparison between the analytically predicted damage and the observed damage from the experimental tests of the panels is performed throughout the loading history. Subsequently, the effects of two important parameters, the orientation and the percentage of reinforcement, on the damage of such shear-dominated panels are studied. The research results demonstrated that the analytically predicted damage is in reasonably good agreement with the observed damage throughout the entire loading history. Furthermore, the orientation and percentage of reinforcement is found to have considerable effect on the extent of damage.  相似文献   

13.
Proposed in this paper are two analytical models for predicting the inelastic response of unreinforced brick masonry infills in reinforced concrete frames subjected to mono-tonic and reversed cyclic loading. The first model is based on the traditional diagonal strut concept, while the second one is a simple isoparametric element with shear deformation only. All the essential characteristics of the hysteretic behaviour of the panel, including strength and stiffness degradation, pinching and slippage, are explicitly taken into account. The models are implemented in a general-purpose program for the inelastic time-history analysis of structures, and are used for studying the seismic behaviour of typical multistorey frames with various arrangements of infill panels, including structures with an open ground storey. The results of the analysis are in agreement with both experimentally observed behaviour and with experience regarding seismically damaged buildings.  相似文献   

14.
This article presents the experimental results of a study on reinforced-concrete frames infilled with masonry with openings. The frames were designed according to current European codes. They were built in a scale 1:2.5 and infilled with masonry walls. Mid-size window and door openings were located centrically and eccentrically and were executed with and without tie-columns around them. Presence of masonry infill, although not accounted for in design, improved the system behavior (increase in stiffness, strength and energy dissipation capacity) at drift levels of up to 1%. During the test, openings did not influence the initial stiffness and strength at low drift levels. Their presence became noticeable at higher drift levels, when they lowered the energy dissipation capacity of the system. The infill wall had a multiple failure mechanism that depended on the opening height and position. Tie-columns controlled the failure type, independent of the opening type, prevented out-of-plane failure of the infill, and increased the system's ductility. Negative effects of the infill on the frame were not observed. The infill's contribution could be deemed positive as it enhanced the overall Structural Performance Level. Analytical expressions commonly used for infilled frames underestimate the infill's contribution to strength and stiffness and overestimate the contribution of the bare frame.  相似文献   

15.
The damaging effects of aftershocks are overlooked by current building codes and not properly accounted for in commercial seismic loss assessment software. In this paper, an evaluation of the seismic fragility relationships for reinforced concrete (RC) frame systems prone to mainshock-aftershocks sequences is conducted. Fiber-based finite element models for different types of RC frames are established and subjected to a suite of ground motions obtained from the Tohoku sequence. Fragility relationships are derived with and without consideration to multiple earthquake effects. The results from this study confirm that multiple earthquakes have significant effects on the vulnerability relationships of RC frames.  相似文献   

16.
Fragility functions play an essential role in evaluating the seismic vulnerability of structures. To establish the seismic fragility functions of lightly Reinforced Concrete (RC) beam-column joints, the Park-Ang Damage model has been amended to quantify the damage states and the modified Bouc-Wen-Baber-Noori model has been employed and implemented in ABAQUS to predict the structural hysteresis behavior. Following successful calibration of the numerical results of a RC test frame from literature, the proposed model has been utilized to assess the seismic fragility curves of low to mid-rise RC frames in Singapore for 30 scaled ground motions using incremental dynamic analysis approach.  相似文献   

17.
Structures designed according to earlier codes with inadequate seismic provisions have not performed satisfactorily during recent earthquakes. The seismic performance of an existing three-storey reinforced concrete building designed according to the 1963 ACI 313-63 is evaluated and compared to the performance of a similar frame designed according to current code provisions. Non-linear static and dynamic analyses of the reinforced concrete frames are conducted. In this study, a probabilistic approach is adopted where a large number of artificially generated ground motion records is used as input motion to the structure. The results of the analysis indicated the probability of various degrees of damage to be expected when the existing frame is subjected to different ground motion levels. This information is useful in the design of the required rehabilitation scheme to provide an identified level of protection.  相似文献   

18.
In the last decades, particular attention has been paid to the seismic vulnerability of existing reinforced concrete buildings designed for gravity loads only. Such buildings, designed before the introduction of capacity design in modern seismic codes, are very common, particularly in seismic prone countries of the Mediterranean area. Due to poor detailing and lacking of capacity design principles, high vulnerability has been highlighted in several past studies. In this article, inadequate seismic response and peculiar damage pattern are investigated by means of shake table tests performed on a 1:2 scaled 3-story infilled prototype. Particular attention is given to the role of beam-column joints and frame-panel interaction. The effectiveness of the EC8-based assessment approach is then evaluated; both linear and nonlinear numerical models, with different levels of sophistication, have been implemented in order to explore their behavioral aspects.  相似文献   

19.
ABSTRACT

This study investigates the seismic response of reinforced concrete buildings designed according to the current Italian building code. Number of stories, site hazard, presence and distribution of masonry infill panels, and type of lateral resisting system are the key investigated parameters. The main issues related to design and modeling are discussed. Two Limit States are considered, namely Global Collapse and Usability-Preventing Damage. The main aim of the study is a comparison between the seismic response of the buildings, investigated through nonlinear static and dynamic analyses. Irregularity in the distribution of infill panels and site hazard emerge as the most influential parameters.  相似文献   

20.
Three different Nonlinear Static Methods (NSM's), based on pushover analysis, are applied to a 3-story, 2-bay, RC frame. They are (i) the Capacity Spectrum Method (CSM), described in ATC-40, (ii) the Displacement Coefficient Method (DCM), presented in FEMA-273 and further developed in FEMA 356, and (iii) the N2 Method, implemented in the Eurocode 8. Pushover analyses are conducted with DRAIN-3DX by using four different lateral force distributions, according to the acceleration profile assumed along the height of the structure: uniform, triangular, modal-proportional, and multimodal fully adaptive. In the numerical model, RC members are modeled as fiber elements.

The numerical predictions of each method are compared to the experimental results of the shaking table tests carried out on two similar 1:3.3-scale structural models, with and without infilled masonry panels, respectively. The comparison is made in terms of maximum story displacements, interstory drifts, and shear forces. All the NSM's are found to predict with adequate accuracy the maximum seismic response of the structure, provided that the associated parameters are properly estimated. The lateral load pattern, instead, is found to little affect the accuracy of the results for the three-story model considered, even if collapse occurs with a soft story mechanism.  相似文献   