首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到7条相似文献,搜索用时 0 毫秒
1.
Simplified expressions to estimate the behavior factor of plane steel moment resisting frames are proposed, based on statistical analysis of the results of thousands of nonlinear dynamic analyses. The influence on this factor of specific structural parameters, such as the number of stories, the number of bays, and the capacity design factor of a steel frame, is studied in detail. The proposed factor describes the seismic strength requirements in order to restrict maximum storey ductility to a predefined value. Interrelation studies between maximum storey ductility and the Park-Ang damage index are also provided for the damage-based interpretation of the performance levels under consideration. Realistic design examples serve to demonstrate the ability of the proposed factor to convert conventional force-based design to a direct performance-based seismic design procedure.  相似文献   

2.
In this article, a performance-based seismic design (PBD) methodology is proposed for the design of reinforced concrete buildings, taking into account the influence of infill walls. Two variants of the PBD framework are examined: The first is based on the non-linear static analysis procedure (NSP) while the second relies on the non-linear dynamic analysis procedure (NDP). Both design approaches are compared in the context of structural optimization with reference to the best possible design achieved for each case examined. Life-cycle cost analysis is considered a reliable tool for assessing the performance of structural systems and it is employed in this study for assessing the optimum designs obtained. The optimization part of the problem is performed with an Evolutionary Algorithm while three performance objectives are implemented in all formulations of the design procedures. The two most important findings can be summarized as follows: (i) if structural realization follows the design assumptions, then total expected life-cycle cost of the three type of structures, bare, fully infilled and open ground story, is almost the same and (ii) if an open ground story building is designed as bare or as fully infilled frame, real performance will be much worse than anticipated at the design stage.  相似文献   

3.
An optimization method based on uniform damage distribution is used to find optimum design load distribution for seismic design of regular and irregular shear-buildings to achieve minimum structural damage. By using 75 synthetic spectrum-compatible earthquakes, optimum design load distributions are obtained for different performance targets, dynamic characteristics, and site soil classifications. For the same structural weight, optimum designed buildings experience up to 40% less global damage compared to code-based designed buildings. A new general load distribution equation is presented for optimum performance-based seismic design of structures which leads to a more efficient use of structural materials and better seismic performance.  相似文献   

4.
A new robust design methodology to control the seismic performance of asymmetric structures equipped with a Single Tuned Mass Damper (STMD) is presented in this article. This design approach aims to control the seismic response of such systems by reducing both flexible-and stiff-edge maximum displacement. The dynamic problem has been investigated in the state space representation showing that the TMD works as a closed-loop feedback control action. A synthetic index to estimate the seismic performance of the main system has been defined by using H norm. Wide-ranging parametric numerical experimentation has been carried out to obtain design formulae for the STMD in order to minimize such a performance index. These formulae allow for a simple design of STMD position and stiffness to optimally control both translational and rotational motion components, whereas two mass devices are generally considered to improve the seismic performance of asymmetric structural systems The effectiveness and efficiency of the obtained design formulae have been tested by investigating the dynamic behavior of the asymmetric structure after being subjected to different recorded seismic inputs.  相似文献   

5.
A series of eccentrically braced frames (EBF) are designed and subjected to nonlinear analyses to highlight ambiguities and differences in current seismic design provisions for EBF structures. This provides motivation to implement better guidance for the checking of local displacement demand considerations and move towards a displacement-based design approach. A recently proposed direct displacement-based design (DDBD) procedure for EBFs is then described and further developed in this article through the calibration of a spectral displacement reduction factors that relate the displacement of an inelastically responding structure to that of the equivalent linear representation used in the DDBD of EBFs. Such an expression is calibrated as part of this study using an experimentally validated numerical model also proposed here for the EBF links such that the actual hysteretic behavior of the links is well represented. The DDBD guidelines are applied to EBF systems from 1–15 stories in height and their performance is verified via nonlinear dynamic analyses using two different sets of design spectrum compatible ground motions. The results of the study indicate the robustness of the proposed DDBD method in limiting the interstory drifts to design limits for a variety of EBF systems with short links, thus demonstrating that the proposed DDBD method is an effective tool for seismic design of EBFs.  相似文献   

6.
Connections of steel moment frames are vulnerable to brittle failure. Providing a perforation near the beam-ends is suggested as a potential method to improve seismic behavior of these structures. This article presents a numerical study on the energy dissipation of steel moment connections with perforated beam. Models with elongated circular openings of different dimensions and location are analyzed and compared based on the global and local damage indices, predicted failure time and dissipated energy. Results show that an RWS connection with a proper opening size can develop reasonable inelastic deformations and provide an acceptable seismic improvement to moment-resisting frames.  相似文献   

7.
The study implements the performance-based analysis and design methodology to assess the seismic vulnerability of a coal-fired power plant and to optimally design its equivalent pendulum-type tuned mass damper system such that the direct losses are minimized. A building-specific total loss ratio is developed to link the component level losses with the total repair cost of the original structure. The optimal system configuration is finally derived for cases with the minimum loss. The study demonstrates a systematic way of achieving the optimal pendulum-type tuned mass damper design with considerations of uncertainties in earthquake inputs and the combined component level damages.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号