首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到7条相似文献,搜索用时 15 毫秒
1.
A self-centering concrete wall with distributed friction devices is proposed to achieve seismic resilient building structures. Unbonded post-tensioned tendons, running vertically through wall panels, provide a restoring force that pulls the structure back toward its undeformed plumb position after earthquake. Two steel jackets are installed at wall toes to prevent concrete spalling and crushing. Friction devices are distributed between the wall and its adjacent gravity columns to achieve controllable energy dissipation, and these devices are readily replaceable. Desirable self-centering and energy dissipation capacities were observed in low-cyclic loading tests, and influences of various parameters on the hysteretic behavior were investigated.  相似文献   

2.
An experimental investigation was undertaken to study the seismic performance of external reinforced concrete (RC) beam-column joints having representative details for mid-rise RC frame buildings in developing countries such as Iran that were designed and constructed prior to the 1970s. Three half-scale external RC beam-column joints were tested by applying lateral cyclic loading of increasing amplitudes. Tested specimens were comprised of one unit having seismic reinforcement detailing in accordance with the seismic requirements of ACI 318-11, and two units having non-seismic reinforcement detailing in accordance with the 1970s construction practice in many developing countries, such as Iran. Two typical defects were considered for the non-seismic units, being the absence of transverse steel hoops and insufficient bond capacity of beam bottom reinforcing bars in the joint region. Test results indicated that the non-seismically detailed specimens had a high rate of strength and stiffness degradation when compared to the seismically detailed specimen, which was attributed primarily to the joint shear failure or bond failure of the beam bottom bars. The non-seismically detailed specimens also showed a 30% reduction in both average strength and ductility and a 60% loss of energy dissipation capacity in comparison to the seismically detailed specimen.  相似文献   

3.
This article is an attempt to study the effects of a stress pulse simulating strong vertical excitation, particularly at the first steps of the mode of propagation. The structural model represents a two-story single column, having two pairs of cantilever beams on either side. The study is carried out by means of the experimental method of caustics. The areas of maximum stress concentration, as well as the wave front direction within the horizontal elements of the structure, are determined. The influence of the wave and the reflected effects on the top of the column are also studied. The experimental results are compared with the corresponding results obtained by finite element analysis. The results could be used for the development of rules for the effects of the vertical component.  相似文献   

4.
This article presents the seismic fragility analysis of a self-centering steel moment-resisting frame (SC-MRF) with web friction devices. A detailed numerical model of the SC frame was developed using the Open System for Earthquake Engineering Simulation (OpenSees) and the elastoplastic responses of the SC-MRF were studied, including the strength degradation under cyclic loading, tendon rupture, beam buckling, bolt bearing and friction loss, etc. The proposed simulation approach is validated by comparing the simulated results with those in existing hybrid-simulation tests, quasi-static pushover test and low cyclic tests, where good agreement is observed. In addition to the well-established performance limit states (i.e., immediate occupancy, collapse prevention and global dynamic instability), two unique performance limit states (i.e., the recentering and repairable limit states) are defined for the SC-MRF. Finally, incremental dynamic analyses are conducted to evaluate the seismic fragilities regarding the five performance limit states.  相似文献   

5.
The problem of multi-objective seismic design optimization is examined within the context of passive energy dissipation systems. In particular, a genetic algorithm approach is developed to enable the evaluation of the Pareto front, where maximum inter-story drifts and maximum total accelerations, both important measures for damage, serve as objectives. Here the cost of the passive system is considered as a constraint, although it could be included instead as a third objective. Hysteretic, viscoelastic and viscous dampers are all considered as possible design strategies, as well as the weakening plus damping concept. Since different types of passive systems are included, diversity of the Pareto front becomes a key issue, which is addressed successfully through an innovative definition of fitness. The multi-objective framework enables the evaluation of trade-offs between the two objectives and, consequently, provides vital information for the decision maker. Furthermore, the results presented offer valuable insight into the characteristics of optimal passive designs for the different objectives. Some of these characteristics confirm results reported elsewhere, while others are presented here for the first time.  相似文献   

6.
The seismic performance of superimposed reinforced concrete (RC) shear walls is decreased by rocking behavior and damage concentration at the horizontal joint. An enhanced horizontal joint method is proposed to improve the corresponding seismic performance. To validate the reliability of the proposed method, three full-scale superimposed walls and a cast-in-place shear wall (for comparison) are designed and tested under the quasi-static load. The test results indicate that the rocking phenomenon can be prevented using the proposed method, and the seismic performance of superimposed RC shear walls with enhanced horizontal joints is comparable to that of the cast-in-place RC shear walls.  相似文献   

7.
A prototype diesel generator equipped with a vibration isolation system consisting of restrained isolators (denoted as I/system) is quasi-statically and dynamically tested. Sequentially, the seismic simulation tests are conducted to further investigate the effectiveness of additional snubbers incorporated into the vibration isolation system (denoted as I/R system). Comparing the test results to the static design demands specified in ASCE 7-10, the recommended component amplification factor could represent the horizontal acceleration amplification phenomenon of the generator equipped with I/R system; however, the seismic force demands for static design of I/R system might not be appropriate and conservative enough.  相似文献   