基于根据宋代《营造法式》制作的某单层单开间殿堂式木结构振动台模型,建立了考虑柱础滑移隔震、榫卯半刚性连接及斗栱减震性能的空间杆系有限元模型。通过模型的数值计算值与振动台实测数据之间的对比分析,验证了建模方法的正确性。提出了柱脚滑移倒塌的相对位移判定准则及柱架层间倒塌的最大层间位移角判定准则,并采用增量动力分析(IDA)方法对这两种倒塌机制进行研究。结果表明:木结构古建筑在普通地震波作用下不易出现柱脚滑移倒塌;层间倒塌为长周期地震波作用下最易出现的倒塌机制;相对于普通地震波而言,木结构古建筑受长周期地震波作用的影响更大。  相似文献   

2.
This article presents the seismic fragility analysis of a self-centering steel moment-resisting frame (SC-MRF) with web friction devices. A detailed numerical model of the SC frame was developed using the Open System for Earthquake Engineering Simulation (OpenSees) and the elastoplastic responses of the SC-MRF were studied, including the strength degradation under cyclic loading, tendon rupture, beam buckling, bolt bearing and friction loss, etc. The proposed simulation approach is validated by comparing the simulated results with those in existing hybrid-simulation tests, quasi-static pushover test and low cyclic tests, where good agreement is observed. In addition to the well-established performance limit states (i.e., immediate occupancy, collapse prevention and global dynamic instability), two unique performance limit states (i.e., the recentering and repairable limit states) are defined for the SC-MRF. Finally, incremental dynamic analyses are conducted to evaluate the seismic fragilities regarding the five performance limit states.  相似文献   

3.
Contemporary seismic design is based on dissipating earthquake energy through significant inelastic deformations. This study aims at developing an understanding of the inelastic behavior of braced frames of modular steel buildings (MSBs) and assessing their seismic demands and capacities. Incremental dynamic analysis is performed on typical MSB frames. The analysis accounts for their unique detailing requirements. Maximum inter-story drift and peak global roof drift were adopted as critical response parameters. The study revealed significant global seismic capacity and a satisfactory performance at design intensity levels. High concentration of inelasticity due to limited redistribution of internal forces was observed.  相似文献   

4.
In this article, seismic vulnerability assessment is carried-out on a novel hybrid structure (steel moment resisting frame (SMRF) and cross laminated timber (CLT) infill panels). For the seismicity of Vancouver, Canada, a three-bay, 3-, 6-, and 9-story height SMRFs are designed for two ductility levels (ductile and limited ductility). To study the seismic vulnerability CLT infilled building, parametric analysis was performed by varying infill configuration (bare frame, one-bay infilled, two-bay infilled, and fully infilled). The structure is modeled in OpenSees and nonlinear dynamic analysis is performed. Peak inter-story drift demand and corresponding FEMA performance limits (capacity) values are used to compute the corresponding fragility curves. From the analyses, it can be seen that as more bays are infilled, the fundamental period and seismic vulnerability is reduced significantly. The results highlight that, within the performance-based earthquake engineering, different objectives can be met with varying the CLT configuration.  相似文献   

5.
Previous research has proposed the Linked Column Frame (LCF) as a lateral load-resisting system capable of providing rapid return to occupancy for buildings impacted by moderate earthquake events and collapse prevention in very large events. The LCF consists of flexible moment frames (MF) and linked columns (LC), which are closely spaced dual columns interconnected with bolted links. The linked columns (LC) are designed to limit seismic forces and provide energy dissipation through yielding of the links, while preventing damage to the moment frame under certain earthquake hazard levels. The proposed design procedure ensures the links of the linked column yield at a significantly lower story drift than the beams of the moment frame, enabling design of this system for two distinct performance states: rapid repair, where only link damage occurs and quick link replacement is possible; and collapse prevention, where both the linked column and moment frame may be damaged.

Here, the seismic performance factors for the LCF system, including the response modification factor, R, the system over-strength factor, Ω0, and the deflection amplification factor, Cd, are established following the procedures described in FEMA P695 [2009]. These parameters are necessary for inclusion of the system in the building code. This work describes the development of archetype structures, numerical models of the LCF systems, incremental dynamic analyses, and interpretation of the results. From the results, it is recommended that R, Ω0, and Cd values of 8, 3, and 5.5 be used for seismic design of the LCF system. A height limit of 35 m (115ft) is recommended at this time as taller LCFs are not considered in this study.  相似文献   

6.
Despite the fact that Eccentrically Braced Frames with Vertical Links (VL-EBFs), also referred to as inverted Y-scheme, are codified in Eurocode 8, the issues related to their seismic response and design have not been widely investigated, so that design criteria commonly applied for Eccentrically Braced Frames with Horizontal Links (HL-EBFs) are commonly applied. However, the Theory of Plastic Mechanism Control (TPMC) has been recently extended to the case of VL-EBFs. The aims of this article, on one hand, are to provide a further validation of the recently proposed design procedure, based on TPMC, and, on the other hand, are to compare the seismic performance of dual systems composed by a moment-resisting part and VL-EBF part designed by means of TPMC with those occurring when Eurocode 8 design criteria are applied. The validation of the proposed design procedure is carried out by means of Incremental Dynamic Analyses (IDA). The main purpose of such analyses is the check of the fulfilment of the design goal of TPMC, i.e., the development of a pattern of yielding consistent with the collapse mechanism of global type. Such mechanism is universally recognized as the one leading to the highest energy dissipation capacity. In case of MRF-EBF dual systems, it is characterized by the yielding of all the links and all the beams at their ends. Conversely, all the columns and the diagonal braces remain in elastic range. Obviously, exception is made for the base sections of first story columns. In particular, two case studies are analyzed which are characterized by a different number of stories. Each building structure is designed according to both TPMC and Eurocode 8 provisions. The seismic response obtained is investigated by both push-over and IDA analyses. The attention is focused on the pattern of yielding obtained, the maximum interstory drift demand, the link plastic rotation demand and sharing of the seismic base shear between the moment-resisting part and the bracing part of the structural system. The results obtained point out improvement of the seismic response, compared to Eurocode 8 provisions, achieved by means of TPMC.  相似文献   

7.
In this article, the seismic behavior of RC wide beam-column connections designed primarily for gravity loads is evaluated experimentally. A 2/3 scale model of one exterior and one interior connection is constructed and subjected to seismic simulations on a shaking table until collapse. The results of the tests indicate that: (a) the drift at yield is from 3 to 6 times higher than, for example, the 0.5% admitted by Eurocode 8 to satisfy the “damage limitation requirement;” (b) the beam-column joints do not fail; (c) the torsion in the spandrel beams governs the overall load-displacement relationship of the exterior connections and limits the ultimate strength. Based on the test results, a nonlinear model for predicting the hysteretic behavior and the failure of the connections is suggested. The model can be implemented in a computer code for evaluating the vulnerability of this type of structure through nonlinear dynamic response analyses.  相似文献   

8.
Shake table tests were carried out on a 7 m × 5 m three-story, timber light-frame building (7.5 m height) at the TreesLab laboratory (Eucentre) in Pavia. The aim of the research was to evaluate the seismic behavior of a typical Italian prefabricated timber building and to study the interaction between the individual structural components tested in quasi-static manner in a previous experimental study. The 1979 Montenegro Earthquake ground motion, recorded at the Ulcinj-Hotel Albatros station, was selected as the ground motion for seismic tests. The maximum peak ground acceleration was scaled to 0.07 g, 0.27 g, 0.5 g. 0.7 g, and 1 g in order to evaluate the building’s performance at different levels of seismic input. More than 100 instruments were used to monitor the behavior of the building during seismic tests measuring acceleration, displacement, and forces. The visual inspection shows that the building did not show any damage during all seismic tests. However the data analysis (dynamic identification, capacity spectrum, inter-story drift) confirm that during the 1.00 g test the structure went beyond its linear elastic limit. The results obtained from this experimental study suggest that the design hypotheses commonly adopted in practice for seismic analysis (e.g., in terms of force distributions between the walls, and also the behavior factor q) are not always consistent with the real behavior of timber frame multi-story buildings, and should be backed by more accurate knowledge of the contributions of the individual structural components.  相似文献   

9.
ABSTRACT

The paper analyzes the static behavior and the seismic vulnerability of the “San Francesco ad Alto” building in Ancona (Italy), which is currently used as a Regional Headquarter of the Marche Region by the Italian Army and was formerly a monastery. The global static structural behavior and the dynamic properties have been evaluated using the Finite Element modeling technique, in which the nonlinear behavior of masonry has been taken into account by proper constitutive laws. The concepts of homogenized material and smeared cracking are used to evaluate the capacity of the monastery to withstand lateral loads together with the expected demands resulting from seismic actions (N2 method), using a nonlinear static analysis (pushover). The comparison of seismic demand and capacity confirms the susceptibility of these types of buildings to extensive damage and collapse, as frequently observed in similar buildings. This paper aims to point out that advanced numerical analyses can offer significant information on the understanding of the actual structural behavior of historical buildings. It is believed that the methodology and the overall conclusions of this case study are valid for many historical monasteries in Europe.  相似文献   

10.
The role of residual deformations when evaluating the performance of multi-storey frame structures subjected to ground motion is investigated in this paper. The limitations of damage indices available in the literature, either based on ductility, energy dissipation or a combination of both, in capturing such a significant aspect of the seismic response of frame structures are discussed. The concept of residual deformations as a critical complementary indicator to cumulative damage, introduced in a companion paper (Part I) for single-degree-of-freedom (SDOF) systems, is herein extended to multi-degree-of-freedom (MDOF) frame systems. The seismic performance of multi-storey frame structures, either representative of new designed or existing structures, is investigated, focusing on the response in terms of residual deformations. Residual deformations are shown to be sensitive to the hysteretic rule adopted, to the system inelastic mechanism as well as to the seismic intensity. The influence of higher modes and P-Δ effects on the final residual deformations is addressed. A combination of maximum drift and residual drift in the format of a performance matrix is used to define the system's global performance levels and is then extended to a framework for an alternative performance-based seismic design and assessment approach.  相似文献   

11.
This article presents a simplified procedure for assessing the seismic performance of existing low-to-medium rise confined masonry (CM) buildings, which are a typical construction type in Latin-America. The procedure consists of the estimation of the peak roof and first-story inelastic drift demand of CM buildings. The expected peak inelastic displacement demand is related to drift-based fragility curves, which express the probability of being or exceeding two key damage states in the masonry panels, developed from a relatively large experimental database. The proposed procedure could be very useful for obtaining rapid estimates of expected performance during future earthquake events and for assessing the seismic vulnerability of regular confined masonry structures.  相似文献   

12.
This study focuses on effect of degradation characteristics on seismic performance of simple structural systems. Equivalent single degree of freedom systems are used for which the structural characteristics are taken from existing reinforced concrete (RC) frame buildings. Simulation of degrading behavior is achieved by considering actual experimental data. To obtain the seismic response of degrading structural systems, two different approaches are used: inelastic spectral analysis and fragility analysis. According to the results obtained from both approaches, degrading behavior is dominant for mid-rise RC frame buildings as it significantly amplifies seismic demand. Hence, in performance-based assessment approaches, analytical modeling of such degrading structures should be carried out carefully.  相似文献   

13.
The FEMA P-807 Guidelines were developed for retrofitting soft-story wood-frame buildings based on existing data, and the method had not been verified through full-scale experimental testing. This article presents two different retrofit designs based directly on the FEMA P-807 Guidelines that were examined at several different seismic intensity levels. The effects of the retrofits on damage to the upper stories were investigated. The results from the hybrid testing verify that designs following the FEMA P-807 Guidelines meet specified performance levels and appear to successfully prevent collapse at significantly higher seismic intensity levels well beyond for which they were designed. Based on the test results presented in this article, it is recommended that the soft-story-only retrofit procedure can be followed when financial or other constraints limit the retrofit from bringing the soft-story building up to current code or applying performance-based procedures.  相似文献   

14.
The goal of this paper is to develop a modified Bouc-Wen hysteretic model from cyclic loading test data for reinforced columns, including the behavior of stiffness degradation, strength deterioration, pinching and softening effects of RC members. Seismic demands on this inelastic single degree of freedom system when subjected to both near-fault ground motion and far-field ground motion excitations were examined.

The cyclic loading test of reinforced concrete columns was experimentally observed and a system identification computer program was developed to solve each control parameter of the hysteretic model. A least-squared method for identifying parameters of the model is proposed in this paper. The hysteretic constitutive law produces a smoothly varying hysteresis such as the control-parameters for strength deterioration, stiffness degradation, pinching and softening effects. Two implementations of (1) flexure damage and (2) shear damage were conducted to provide better understanding of hysteretic behavior of RC structural members. A pseudo-dynamic experiment was also developed to verify the model parameters.

Based on the developed hysteretic model, the seismic demand of this inelastic model was investigated by using both near-fault ground motion data and far-field ground motion data as input motion. An RT inelastic response spectrum from different hysteretic models was generated.  相似文献   

15.
The unexpected damages in structures during severe earthquakes have been reported frequently so far. In this study, the damage-based inelastic behavior of special moment resisting frame (SMRF) structures designed according to the new versions of general earthquake loading codes (International building code [IBC] 2012 & American Society of Civil Engineers [ASCE] 7-2010) and seismic design references (National Earthquake Hazards Reduction Program [NEHRP] 2009 & Federal Emergency Management Agency [FEMA] P-750) has been investigated. The final results presented based on distinctive shear and flexural failure modes show that a non-uniform distribution of severe damage in structural height occurs during design level seismic excitations. Also it is observed that the shear and flexural damages are more critical in short and tall MRF structures, respectively.  相似文献   

16.
If RC structural walls are properly designed and proportioned, these walls can behave in a ductile manner. To achieve this goal, the designer should provide adequate strength and deformation capacity of structural walls corresponding to each performance level (e.g. immediate occupancy, life safety and collapse prevention). This study investigates the drift and ductility capacities of T-shaped structural walls on the basis of results from experimental tests and sectional analyses. To determine proper deformation capacities for T-shaped structural walls, structural performances of T-shaped walls were evaluated with several parameters such as longitudinal reinforcement ratio, distribution of longi-tudinal reinforcement, lateral confinement ratio, and axial load ratio. Based on these results, the level of deformation capacity specified in current design provisions (ICBO, UBC 1997), which were expressed as both strain-based damage limit and interstorey drift ratio, were evaluated.  相似文献   

17.
The present study deals with the seismic performance of partial perimeter and spatial moment resisting frames (MRFs) for low-to-medium rise buildings. It seeks to establish perimeter configuration systems and hence the lack of redundancy can detrimentally affect the seismic response of framed buildings. The paper tackles this key issue by com-paring the performance of a set of perimeter and spatial MRFs, which were “consistently designed”. The starting point is the set of low-(three-storey) and medium-rise (nine-storey) perimeter frames designed within the SAC Steel Project for the Los Angeles, Seattle and Boston seismic zones. Extensive design analyses (static and multi-modal) of the perimeter frame buildings and consistent design of spatial frame systems, as an alternative to the perimeter configuration, were conducted within this analytical study. The objectives of the consistent design are two-fold, i.e. obtaining fundamental periods similar to those of the perimeter frames, i.e. same lateral stiffness under design horizon-tal loads, and supplying similar yield strength. The seismic behaviour of perimeter and spatial configuration structures was evaluated by means of push-over non-linear static analyses and inelastic dynamic analyses (non linear time histories). Comparisons be-tween analysis results were developed in a well defined framework since a clear scheme to define and evaluate relevant limit states is suggested. The failure modes, either local or global, were computed and correlated to design choices, particularly those concerning the strength requirements (column overstrength factors) and stiffness (elastic stability indexes). The inelastic response exhibited by the sample MRFs under severe ground motions was assessed in a detailed fashion. Conclusions are drawn in terms of local and global performance, namely global and inter-storey drifts, beam and column plas-tic rotations, hysteretic energy. The finding is that the seismic response of perimeter and spatial MRFs is fairly similar. Therefore, an equivalent behaviour between the two configurations can be obtained if the design is “consistent”.  相似文献   

18.
This article is the first of two companion articles addressing the statistical characterization of seismic demand. Performance-based earthquake engineering methodologies often require the characterization of central value estimates of structural demand. Since outliers can occur in the data, central value estimates should be determined by robust estimation methods. The performance of 50 robust central value estimators is evaluated, for different sample sizes, using the chord rotation, curvature, shear force, and inter-story drift demands obtained after analyzing five reinforced concrete structures under real earthquake records scaled to several intensities. Based on the results, seven estimators are proposed for different sample sizes.  相似文献   

19.
The concept of base isolation is a century old, but application to civil engineering structures has only occurred over the last several decades. Application to light-frame wood buildings in North America has been virtually non existent with one notable exception. This article quantitatively examines issues associated with application of base isolation in light-frame wood building systems including: (1) constructability issues related to ensuring sufficient in-plane floor diaphragm stiffness to transfer shear from the superstructure to the isolation system; (2) evaluation of experimental seismic performance of a half-scale base-isolated light-frame wood building; and (3) development of a displacement–based seismic design method and numerical model and their comparison with experimental results. The results of the study demonstrate that friction pendulum system (FPS) bearings offer a technically viable passive seismic protection system for light-frame wood buildings in high seismic zones. Specifically, the amount and method of stiffening the floor diaphragm is not unreasonable, given that the inter-story drift and accelerations at the upper level of the tested building were very low, thus resulting in the expectation of virtually no structural, non structural, or contents damage in low-rise wood frame buildings. The nonlinear dynamic model was able to replicate both the isolation layer and superstructure movement with good accuracy. The displacement-based design method was proven to be a viable tool to estimate the inter-story drift of the superstructure. These tools further underscore the potential of applying base isolation systems for application to North America's largest building type.  相似文献   

20.
Previous studies have shown that both distribution and intensity of response parameters in asymmetric buildings are dependent on their stiffnesses and strength distributions. The locations of centers of strength and rigidity relative to the center of mass provide suitable metrics for strength and stiffness distributions. In general, the proper locations of these centers are a function of earthquake ground motion characteristics and the level of building's nonlinear responses. In this article, using nonlinear response evaluation of single-story building models with a wide range of uncoupled torsional to lateral frequencies subjected to near field and far field earthquake excitations the proper location of building centers is studied . Diaphragm rotation, interstory drift, hinge plastic rotation, and ductility demand are selected as damage measure parameters. To compare the performance of models in each limit state, fragility representation of responses is used. It is concluded that proper configuration of building centers in a torsionally stiff building fundamentally depends on the chosen demand parameter. The proper configuration of centers in a torsionally stiff building for a specific demand parameter can converge the probability and distribution of related damages to those in the symmetric building counterpart. When the critical demand parameter for a case is identified, its corresponding arrangements of centers for a suitable seismic behavior may also be recognized. By rearranging the configuration of centers based on the attained configuration, the adverse effects of asymmetry can be avoided.  相似文献   