首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this paper, a methodology is suggested and tested for evaluating the relative performance of conventional and adaptive pushover methods for seismic response assessment. The basis of the evaluation procedure is a quantitative measure for the difference in response between these methods and inelastic dynamic analysis which is deemed to be the most accurate. Various structural levels of evaluation and different incremental representations for dynamic analysis are also suggested. This method is applied on a set of eight different reinforced concrete structural systems subjected to various strong motion records. Sample results are presented and discussed while the full results are presented alongside conclusions and recommendations, in a companion paper.  相似文献   

2.
The recent drive for use of performance based methodologies in design and assessment of structures in seismic areas has significantly increased the demand for the development of reliable nonlinear inelastic static pushover analysis tools. As a result, the recent years have witnessed the introduction of the so-called adaptive pushover methods, which, unlike their conventional pushover counterparts, feature the ability to account for the effect that higher modes of vibration and progressive stiffness degradation might have on the distribution of seismic storey forces. In this paper, the accuracy of these force-based adaptive pushover methods in predicting the horizontal capacity of reinforced concrete buildings is explored, through comparison with results from a large number of nonlinear time-history dynamic analyses. It is concluded that, despite its apparent conceptual superiority, current force-based adaptive pushover features a relatively minor advantage over its traditional non-adaptive equivalent, particularly in what concerns the estimation of deformation patterns of buildings, which are poorly predicted by both types of analysis.  相似文献   

3.
In this paper, an innovative displacement-based adaptive pushover procedure, whereby a set of laterally applied displacements, rather than forces, is monotonically applied to the structure, is presented. The integrity of the analysis algorithm is verified through an extensive comparative study involving static and dynamic nonlinear analysis of 12 rein-forced concrete buildings subjected to four diverse acceleration records. It is shown that the new approach manages to provide much improved response predictions, throughout the entire deformation range, in comparison to those obtained by force-based methods. In addition, the proposed algorithm proved to be numerically stable, even in the highly inelastic region, whereas the additional modelling and computational effort, with respect to conventional pushover procedures, is negligible. This novel adaptive pushover method is therefore shown to constitute an appealing displacement-based tool for structural assessment, fully in line with the recently introduced deformation- and performance-oriented trends in the field of earthquake engineering.  相似文献   

4.
In this paper, a fairly effective procedure called dynamic load pattern (DLP), is proposed to account for the effects of near-fault ground motions in estimating the seismic demands of structures from pushover analyses. The seismic demands are obtained by enveloping the results of single-run conventional first-mode and single-run DLP pushover analyses. Improving the estimation of target displacement is another objective, implemented by performing response-spectrum analysis. Three special steel moment-resisting frames are considered and the seismic demands resulting from DLP are compared to those from the nonlinear time-history analysis as a benchmark solution, as well as to those predicted from modal pushover analysis.  相似文献   

5.
This article presents the comparison among different nonlinear seismic analysis methods applied to masonry buildings, i.e., pushover analyses with invariant lateral force distributions, adaptive pushover analysis and nonlinear dynamic analysis. The study focuses on the influence of lateral force distribution on the results of the pushover analysis. Two simple benchmark case studies are considered for the purpose of the research, i.e., a four-wall masonry building prototype without floor rigid diaphragms and a two-wall system with a cross-vault. The comparative study offers a useful review of pushover analysis methods for masonry structures and shows advantages and possible limitations of each approach.  相似文献   

6.
ABSTRACT

Kinetic analysis methods based on linear and nonlinear rigid body dynamics are used to evaluate earthquake safety of masonry structures. In this study, the formulas used to calculate the in-plane and out-of-plane load capacities of masonry load-bearing walls were evaluated and a procedure based on rigid body mechanism was proposed to calculate the out-of-plane load capacities of the walls of Ottoman period masonry mosques. New aspects of the method with respect to existing formulations is the inclusion of dynamic axial load and definition of the collapse limit spectral acceleration on the overturning wall. The calculated capacities of the mosque and individual walls were compared with the results of nonlinear pushover analysis and time history analyses performed under 1.0 and 0.5 scaled forms of nine different 3-component ground motion records. It was displayed that the seismic load capacity estimated by the proposed method is very close to the values calculated by pushover and time history analyses. The method was developed on Lala Pasha Mosque, and the reliability and applicability of the proposed methodology is verified on a different historical masonry mosque in comparison to finite element analyses results.  相似文献   

7.
ABSTRACT

A topology optimized rigid triangular FE macro-model with non-linear homogenized interfaces for the pushover analysis of in plane loaded masonry is presented. The shape of the mesh and the position of the interfaces is evaluated through a topology optimization approach that detects the main compressive stress fluxes in the structure. Different values of the horizontal action are considered to derive an adaptive mesh or an optimal discretization that is suitable for multiple loads. Masonry properties are calibrated by means of a homogenization approach in the nonlinear range. To tackle elastic and inelastic deformations, interfaces are assumed to behave as elasto-plastic with softening in both tension and compression, with orthotropic behavior. The two-step procedure competes favorably with classic equivalent frame approaches because it does not require a-priori assumptions on the mesh and on the length of the rigid offsets. An example of technical relevance is discussed, relying into a multi-story masonry wall loaded up to failure.  相似文献   

8.
A seismic design procedure for partially concrete-filled box-shaped steel columns is presented in this paper. To determine the ultimate state of such columns, concrete and steel segments are modelled using beam-column elements and a pushover analysis procedure is adopted. This is done by means of a new failure criterion based on the average strain of concrete and steel at critical regions. The proposed procedure is applicable to columns having thin- and thick-walled sections, which are longitudinally stiffened or not. An uniaxial constitutive relation recently developed is employed for concrete filled in the thick-walled unstiffened section columns. Modifications are introduced to this model for other types of columns. Subsequently, the strength and ductility predictions obtained using the present and previous procedures are compared with the corresponding experimental results. Comparisons show that the present procedure yields better predictions. It is revealed that the inclusion of the confinement effects and softening behaviour of concrete is important in the present kind of prediction procedures. Furthermore, an extensive parametric study is carried out to examine the effects of procedures and geometrical and material properties on capacity predictions.  相似文献   

9.
A five-storey steel frame incorporating dissipative knee elements is designed using the Eurocode 8 pushover analysis method. The non-linear analysis makes use of a novel knee element model capable of accurately simulating the bending and shear behaviour observed in full-scale tests. The performance of the structure is assessed using non-linear time-history analysis. This shows that the knee elements can be designed to yield under small earthquakes or early in a strong one (maximising their energy dissipation) while still being able to withstand a large event without collapse. Knee elements thus have the potential to give excellent seismic performance in steel framed structures. The time history analysis results are compared to those obtained with the three different pushover analysis methods (Eurocode 8, FEMA 356 and ATC 40). The FEMA 356 method, which includes a more accurate representation of the structure's significant post-yield stiffness, gave the closest agreement with the time history analyses, while the Eurocode 8 method gave rather conservative results and the ATC 40 method appears non-conservative for this type of structure.  相似文献   

10.
ABSTRACT

This article aims at contributing to the seismic performance assessment of a historic brick masonry building by finding a strength reduction coefficient through the use of linear and nonlinear modeling approaches, using Finite Element Method and Equivalent Frame modeling. To reduce the uncertainties, ambient vibration tests (AVT) were implemented. Series of simulations was performed using nonlinear dynamic analyses and incremental dynamic analysis curves were compared with the pushover curves. Results indicate that the mass-proportional pushover curve meets the mean of results obtained from IDA and the strength reduction coefficient falls into the range given in EN 1998–1 for unreinforced masonry.  相似文献   

11.
The results of a parametric study are presented, concerned with the evaluation of the structural overstrength, the global ductility and the available behaviour factor of existing reinforced concrete (RC) buildings designed and constructed according to past generations of earthquake resistant design codes in Greece. For the estimation of these parameters, various failure criteria are incorporated in a methodology established to predict the failure mode of such buildings under planar response, as described in detail in a companion publication. A collection of 85 typical building forms is considered. The influence of various parameters is examined, such as the geometry of the structure (number of storeys, bay width etc.), the vertical irregularity, the contribution of the perimeter frame masonry infill walls, the period of construction, the design code and the seismic zone coefficient. The results from inelastic pushover analyses indicate that existing RC buildings exhibit higher overstrength than their contemporary counterparts, but with much reduced ductility capacity. The presence of perimeter infill walls increases considerably their stiffness and lateral resistance, while further reducing their ductility. Fully infilled frames exhibit generally good behaviour, while structures with an open floor exhibit the worst performance by creating a soft storey. Shear failure becomes critical in the buildings with partial height infills. It is also critical for buildings with isolated shear wall cores at the elevator shaft. Out of five different forms of irregularity considered in this study, buildings with column discontinuities in the ground storey exhibit the worst performance. Furthermore, buildings located in the higher seismicity zone are more vulnerable, since the increase of their lateral resistance and ductility capacity is disproportional to the increase in seismic demand.  相似文献   

12.
The main purpose of this article is to develop an alternative adaptive pushover method in which multiple inelastic response spectra proportional to the instantaneous ductility ratio of the structure are employed to reflect the actual energy dissipation characteristic of the structure at a given deformation level. Based on the proposed methodology, two load patterns are independently applied to the structure and the envelope of the demand values is computed. The obtained results demonstrate that the proposed method provides improved predictions of the peak interstory and total drift profiles of the structure.  相似文献   

13.
An equivalent linearization procedure is developed for predicting the inelastic deformations and internal forces of capacity-designed structures under earthquake excitations. The procedure employs response spectrum analysis, and mainly consists of the construction of an equivalent linear system by reducing the stiffness of structural members that are expected to respond in the inelastic range. These members are well defined in structures designed with capacity principles. Maximum modal displacement demands of the equivalent linear system are determined either from the equal displacement rule, or from independent nonlinear response history analysis of SDOF systems representing inelastic modes.

Predictions obtained from the proposed equivalent linearization procedure are evaluated comparatively by using the results of nonlinear response history analysis as benchmark, linear elastic response spectrum analysis and conventional pushover analysis. The deformations and capacity controlled actions of a 12-story symmetrical plan concrete frame and a 6-story unsymmetrical plan concrete frame are obtained by each method under 96 strong ground motions. It is observed that the proposed procedure results in better accuracy in estimating the inelastic seismic displacement response parameters and capacity controlled forces than the other two approximate methods.  相似文献   

14.
The applicability of different pushover methods was analyzed on the example of a bridge, which was experimentally tested on three shake tables at the University of Nevada, Reno. The response of the bridge was quite complex. The intensity as well as the direction of the deck torsional rotations varied significantly, depending on the seismic intensity. At the low intensities, all the employed pushover methods estimated the displacements of the deck very well. In the case of strong earthquakes, the advantages of multi-mode and adaptive methods was demonstrated.  相似文献   

15.
Three different Nonlinear Static Methods (NSM's), based on pushover analysis, are applied to a 3-story, 2-bay, RC frame. They are (i) the Capacity Spectrum Method (CSM), described in ATC-40, (ii) the Displacement Coefficient Method (DCM), presented in FEMA-273 and further developed in FEMA 356, and (iii) the N2 Method, implemented in the Eurocode 8. Pushover analyses are conducted with DRAIN-3DX by using four different lateral force distributions, according to the acceleration profile assumed along the height of the structure: uniform, triangular, modal-proportional, and multimodal fully adaptive. In the numerical model, RC members are modeled as fiber elements.

The numerical predictions of each method are compared to the experimental results of the shaking table tests carried out on two similar 1:3.3-scale structural models, with and without infilled masonry panels, respectively. The comparison is made in terms of maximum story displacements, interstory drifts, and shear forces. All the NSM's are found to predict with adequate accuracy the maximum seismic response of the structure, provided that the associated parameters are properly estimated. The lateral load pattern, instead, is found to little affect the accuracy of the results for the three-story model considered, even if collapse occurs with a soft story mechanism.  相似文献   

16.
ABSTRACT

This paper discusses the seismic risk assessment of a Basilica-type church according to the provisions of the Italian Guidelines. A comparison between the results obtained with local and global approaches is reported, based on a knowledge process aimed to characterize the geometric and mechanical parameters required for a reliable structural analysis. To perform the global analyses the finite element technique was employed, with proper assumptions to account for the nonlinear behavior of masonry. Illustrating a case study, the paper critically discusses about the employability of pushover analysis methods for the seismic assessment of basilica-type churches.  相似文献   

17.
The Uncoupled Modal Response History Analysis (UMRHA) method developed by Chopra et al. is modified in this paper to estimate damage to welded moment-resisting connections in a steel frame (MRSF) subjected to earthquake ground motions. The behaviour of these connections is modelled by a moment-rotation relationship that accounts for the cracking of the beam flange-to-column flange groove weld. The behaviour of the frame is approximated by a sequence of single-degree-of-freedom (SDOF) models for the first three modes to allow for the contribution of higher modes of vibration. The dynamic properties of these SDOF systems are determined by nonlinear static pushover analyses of the building frame. Because of the significant drop in connection strength caused by beam-to-column weld cracking, the pushover procedure uses a changing rather than invariant distribution of horizontal loads, while the structural responses are calculated from shapes that are based on the displaced shape of the frame after damage occurs. The accuracy of the method is demonstrated by a comparison with the results of a nonlinear time history analysis of the frame. This method can be used for rapid assessment of seismic damage or damage potential and to identify buildings requiring more detailed investigation.  相似文献   

18.
The archaeologist must often determine if ceramics having similar designs and forms but from widely separated locations were locally made or are the result of diffusion. This paper describes a methodology of technological analysis of ceramics utilised to solve such a problem. Results of a mineralogical analysis of ceramics and a discussion of the cultural implications of the results is presented. It is concluded that this methodology is an essential tool in distinguishing sites and elucidating relationships within the Sudanese Neolithic.  相似文献   

19.
Considering the likely unfavorable behavior under seismic action of adobe construction, this article aims at providing a seismic fragility characterization of two adobe Portuguese traditional buildings, using numerical models calibrated over experimental results. The study of such two case-study buildings in the region of Aveiro contributes to the understanding of the seismic fragility of adobe construction in the region in general. The buildings were numerically modeled to estimate their structural behavior under seismic loading using adobe material properties that were calibrated based on the experimental results of a cyclic in-plane test of a full-scale double-Tshaped adobe wall. The method chosen to characterize adobe masonry and model its nonlinear behavior followed a total strain crack-based macro-modeling (TSCM) approach, whereas pushover analysis was carried out to reproduce the pseudo-static experimental test in order to enable a refined calibration of adobe masonry mechanical properties. Fragility functions were then derived, based on the above-mentioned numerical models, using nonlinear static analysis, bringing further insight on the seismic fragility of traditional Portuguese adobe construction.  相似文献   

20.
A simplified approach for analyzing the nonlinear response of masonry buildings, based on the equivalent frame modeling procedure and on the nonlinear equivalent static analyses, is presented. A nonlinear beam finite element (FE) is formulated in the framework of a force-based approach, where the stress fields are expanded along the beam local axis, and introduced in a global displacement-based FE code. In order to model the nonlinear constitutive response of the masonry material, the lumped hinge approach is adopted and both flexural and shear plastic hinges are located at the two end nodes of the beam. A classical elastic-plastic constitutive relationship describes the nonlinear response of the hinges, the evolution of the plastic variables being governed by the Kuhn-Tucker and consistency conditions. An efficient element state determination procedure is implemented, which condenses the local deformation residual into the global residual vector, thus avoiding the need to perform the inner loops for computing the element nonlinear response. The comparison with some relevant experimental and real full-scale masonry walls is presented, obtaining a very good agreement with the available results, both in terms of global pushover curves and damage distributions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号