首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this article, a performance-based seismic design (PBD) methodology is proposed for the design of reinforced concrete buildings, taking into account the influence of infill walls. Two variants of the PBD framework are examined: The first is based on the non-linear static analysis procedure (NSP) while the second relies on the non-linear dynamic analysis procedure (NDP). Both design approaches are compared in the context of structural optimization with reference to the best possible design achieved for each case examined. Life-cycle cost analysis is considered a reliable tool for assessing the performance of structural systems and it is employed in this study for assessing the optimum designs obtained. The optimization part of the problem is performed with an Evolutionary Algorithm while three performance objectives are implemented in all formulations of the design procedures. The two most important findings can be summarized as follows: (i) if structural realization follows the design assumptions, then total expected life-cycle cost of the three type of structures, bare, fully infilled and open ground story, is almost the same and (ii) if an open ground story building is designed as bare or as fully infilled frame, real performance will be much worse than anticipated at the design stage.  相似文献   

2.
通过对上海及邻近地区地震危害性分析,结合地震研究工作结果,根据上海博物馆文物防震保护的具体要求,研究确定了该博物馆文物防震保护的设防水准及地震动参数。场地地震动输入峰值加速度水准确定为50年超越概率3%,地震动反应谱采用上海市标准《建筑抗震设计规范》(DGJ08-9-92)中给出的地震影响系数曲线(阻尼比0.05),并将输入峰值加速度调整为180gal。研究采用了目前通用的拟合反应谱的方法,通过拟合选定的地震动反应标准谱,合成了6条人造地震波时程曲线,拟合精度控制在相对误差不大于5%;同时结合上海市《建筑抗震设计规范》(DGJ08-9-92)中所附的一条强震记录,共同作为上海博物馆结构地震反应分析的输入地震动。又根据上海博物馆建筑的结构特征分析,结合建筑结沟动力特征的实测结果,通过采用层模型结构时程分析计算方法,计算并获得了在遭遇设防地震时,上海博物馆建筑物每一层的地震动反应,表明上海博物馆建筑各楼层的地震动反应具有明显的楼层放大作用。对各楼层地震动反应的统计分析,给出了上海博物馆建筑物每一层的地震动参数,以此可作为今后文物地震危害性分析,及研究设计隔震装置等防震措施的依据。  相似文献   

3.
When structural retrofitting of buildings is required due to seismic safety considerations, building owners or government officials are faced with a crucial decision whether to demolish and rebuild their buildings, or retrofit them. Simple decisions based on fixed proportions, such as demolish and rebuild if retrofit costs exceed 40% of the replacement cost, may be misleading. A financial analysis should be carried out considering all the revenues and costs of the building during its life time. A low-cost residential apartment building that has a construction cost of $140/m2 is selected in this study to represent the vulnerable buildings in developing countries under seismic risk. Life-cycle cost analysis approach is employed to value the rebuild or retrofit alternatives to compare economically. Economic assessment has been carried out for various parameters. It has been found that the age of the building and the retrofit ratio are dominant parameters among the others. The critical retrofit ratio (percent of retrofit cost to initial construction cost) varied from 25% for 40 year old buildings to 67% for 10 year old buildings. It is suggested that economical decisons should not be made simply by comparing the retrofit costs to initial construction costs.  相似文献   

4.
Shake table tests were carried out on a 7 m × 5 m three-story, timber light-frame building (7.5 m height) at the TreesLab laboratory (Eucentre) in Pavia. The aim of the research was to evaluate the seismic behavior of a typical Italian prefabricated timber building and to study the interaction between the individual structural components tested in quasi-static manner in a previous experimental study. The 1979 Montenegro Earthquake ground motion, recorded at the Ulcinj-Hotel Albatros station, was selected as the ground motion for seismic tests. The maximum peak ground acceleration was scaled to 0.07 g, 0.27 g, 0.5 g. 0.7 g, and 1 g in order to evaluate the building’s performance at different levels of seismic input. More than 100 instruments were used to monitor the behavior of the building during seismic tests measuring acceleration, displacement, and forces. The visual inspection shows that the building did not show any damage during all seismic tests. However the data analysis (dynamic identification, capacity spectrum, inter-story drift) confirm that during the 1.00 g test the structure went beyond its linear elastic limit. The results obtained from this experimental study suggest that the design hypotheses commonly adopted in practice for seismic analysis (e.g., in terms of force distributions between the walls, and also the behavior factor q) are not always consistent with the real behavior of timber frame multi-story buildings, and should be backed by more accurate knowledge of the contributions of the individual structural components.  相似文献   

5.
The results of a parametric study are presented, concerned with the evaluation of the structural overstrength, the global ductility and the available behaviour factor of existing reinforced concrete (RC) buildings designed and constructed according to past generations of earthquake resistant design codes in Greece. For the estimation of these parameters, various failure criteria are incorporated in a methodology established to predict the failure mode of such buildings under planar response, as described in detail in a companion publication. A collection of 85 typical building forms is considered. The influence of various parameters is examined, such as the geometry of the structure (number of storeys, bay width etc.), the vertical irregularity, the contribution of the perimeter frame masonry infill walls, the period of construction, the design code and the seismic zone coefficient. The results from inelastic pushover analyses indicate that existing RC buildings exhibit higher overstrength than their contemporary counterparts, but with much reduced ductility capacity. The presence of perimeter infill walls increases considerably their stiffness and lateral resistance, while further reducing their ductility. Fully infilled frames exhibit generally good behaviour, while structures with an open floor exhibit the worst performance by creating a soft storey. Shear failure becomes critical in the buildings with partial height infills. It is also critical for buildings with isolated shear wall cores at the elevator shaft. Out of five different forms of irregularity considered in this study, buildings with column discontinuities in the ground storey exhibit the worst performance. Furthermore, buildings located in the higher seismicity zone are more vulnerable, since the increase of their lateral resistance and ductility capacity is disproportional to the increase in seismic demand.  相似文献   

6.
A framework for quick seismic assessment and retrofit of traditional unreinforced masonry (URM) structures is presented. The proposed methods build on simple principles of structural dynamics and are used as an alternative to detailed time-history analysis, in recognition of the prevailing need for simple and practical methods, compatible with the low-budget and the limited level of knowledge regarding materials, internal force paths, connectivity and condition of older URM structures. An objective is to identify areas in the building that are particularly susceptible to damage and for guiding the types of the required global interventions to improve seismic response. Demand and supply are expressed in terms of relative drift ratios that quantify the intensity of out-of-plane differential translation and in-plane shear distortion of masonry walls. A characteristic traditional building type of timber-laced masonry is used as a model structure for illustration of concepts. The morphology and geometry of the building correspond to a statistical sample of the actual traditional unreinforced masonry buildings (TURM) found in historical centers of many towns in the greater region of Northern Greece. The methodology is particularly useful for setting retrofit priorities and management of the collective seismic risk of historical entities.  相似文献   

7.
The effect of autoclaved aerated concrete (AAC) infill walls on the structural system dynamics of a two-story reinforced concrete building is investigated using its finite element structural model, which is calibrated to simulate the acceleration-frequency response curves from its forced vibration test. The model incorporating the AAC infill walls by equivalent diagonal struts captures the increase in lateral stiffness of the building and the torsional motions induced due to the asymmetrically placed AAC infill walls. A higher strut width coefficient than in ASCE/SEI 41-06 is recommended to model the stiffness of the AAC infill walls in the elastic range.  相似文献   

8.
Ground motions recorded in the epicentral region of an earthquake often have a strong vertical component with dominant high frequencies. Damage to bridges in near-source regions due to strong vertical ground motion has been reported. The beneficial effects of footing uplift on structural performance in form of reduction of seismic response of structural members have been confirmed in previous research. The uplift of bridge piers has been utilised in a very limited number of bridge structures, e.g., the South Rangitikei railway bridge in New Zealand. However, the near-fault seismic behaviour of bridges with footing uplift has been even less addressed. In this study shake table investigations were carried out on the response of a single-span bridge model with footing uplift subjected to simultaneous vertical and horizontal excitations. Near-fault ground motions recorded in the Canterbury earthquake sequences of 2010 and 2011 were used. The experimental results show that inclusion of vertical ground motions produce stronger axial force in the pier and larger bending moment in the deck. Concurrent horizontal and vertical excitations may also cause more frequent footing uplift than the solely horizontal excitations.  相似文献   

9.
On September 7, 1999 an earthquake with magnitude M W =5.9 occurred close to the city of Athens in Greece. More than 80 buildings collapsed, about 150 deaths and hundreds of injuries were reported. Soon after the event a damage investigation was carried out by two of the authors in the most heavily struck areas. The most serious damages were observed in the northern suburbs of Athens, where reinforced concrete frames and masonry buildings represent the prevalent construction systems. The hysteretic energy demands imposed on RC buildings should have been rather severe considering the structural systems characteristics and the inadequate construction details. However, over-strengths, redundancy and especially the presence of infill walls, provided a significant increase of the seismic capacity and contributed to the survival of many buildings.

The objective of the present work is to reproduce and analyse the response of typical RC frames subjected to the 1999 Athens earthquake in areas where the observed damage was particularly severe but no recordings of the ground motion were available. After a general overview of the seismotectonic environment, seismological data, observed macro-seismic intensities, structural typologies and observed building behaviour, an attempt is made to identify representative excitations in the meizoseismal area. Specifically, the required accelerograms are obtained by modifying available records so as to reproduce a given global energy content and to be consistent with the observed damage. To study the seismic response of RC models, the obtained accelerograms are used to perform nonlinear dynamic analyses.  相似文献   

10.
In order to promote the research and development on evaluating the seismic performance of structures, China State Construction Engineering Corporation (CSCEC) planned to construct a large-scale loading testing facility, the Multi-Function Testing System (MFTS). This facility can perform full-scale, real-time, 6-degree-of-freedom static and dynamic testing of rubber bearings and many types of structural components including long columns, shear walls and cross shape joints. The basic performances of the MFTS are a clearance of 9.1 m × 6.6 m × 10 m for specimen installation, maximum x-directional displacement 1500 mm, maximum y-directional velocity 1570 mm/s and maximum z-directional compressive load 108 MN. The system configuration and performance specifications of the MFTS are presented in this paper. The inverse kinematics model and the nonlinear model of the hydraulic servosystem of the MFTS are built. A modified feedback forward kinematics algorithm is developed for real-time control of the MFTS. Internal force characteristics of the loading system are analyzed. The internal force control method based on real-time solution of basis of internal force space is proposed for the system with large motion ranges. The motion controller combining position control loop and internal force control loop is developed. To meet the requirement of simultaneously imposing vertical compressive load and horizontal displacement, a mixed load and displacement controller is designed, where a direct force control loop is used to improve the response speed of the force control and reduce spatial dynamic coupling effects. Finally, a dynamic bearing testing is performed. The test results demonstrate that the system using the proposed controller has good abilities on position tracking, force balance, and load following.  相似文献   

11.
The seismic response of base-isolated benchmark building with variable sliding isolators like variable friction pendulum system (VFPS), variable frequency pendulum isolator (VFPI), and variable curvature friction pendulum system (VCFPS), along with conventional friction pendulum system (FPS), was studied under the seven earthquakes. The earthquakes are applied bi-directionally in the horizontal plane ignoring vertical ground motion component. The shear type base-isolated benchmark building is modeled as three-dimensional linear elastic structure having three degrees of freedom at each floor level. Time domain dynamic analysis of the benchmark building was carried out with the help of constant average acceleration Newmark-Beta method and nonlinear isolation forces was taken care by fourth-order Runge-Kutta method. The base-isolated benchmark building is investigated for uniform isolation and hybrid isolation in combination with laminated rubber bearings through the performance criteria and time history response of important structural response parameters like floor accelerations, base displacement, etc. It is observed that variable sliding isolators performed better than conventional FPS due to their varying characteristic properties which enable them to alter the isolator forces depending upon their isolator displacements thus improves the performance of the structure. The VFPS efficiently controls large isolator displacements and VFPI and VCFPS improve super structural response on the cost of isolator displacement. It is also observed that the hybrid isolation is relatively better in comparison to the uniform isolation for the benchmark building.  相似文献   

12.
This article investigates the ductility reduction factors for RC eccentric frame structures subjected to pulse-like ground motions. The structural models are with the strength eccentricities which are much disadvantageous than the stiffness eccentricities during the inelastic response range. A method to determine the ductility reduction factors of the strength eccentric structures is suggested by modifying those of reference symmetric structures through an eccentricity modification factor. The four factors of strength eccentricity ratio, ductility ratio, story number and velocity pulse of ground motions, are investigated to gain insight into this modification factor. It shows that the ductility reduction factors of the eccentric structures are clearly smaller than those of the symmetric structures. The eccentricity modification factor is mainly affected by the strength eccentricity and the ductility ratio, decreasing with the increment of the eccentricity or the decrement of the ductility ratio in a medium eccentricity range. The earthquake pulse-like effect and the eccentricity have coupling influence on the modification factor, while the effect of story number is not apparent. Based on the results of a comprehensive statistical study a simplified expression is suggested, which can estimate the eccentricity modification factors for both pulse-like and nonpulse-like ground motion cases.  相似文献   

13.
In structural analyses, masonry infill walls are commonly considered to be non structural elements. However, the response of reinforced concrete buildings to earthquake loads can be substantially affected by the influence of infill walls. In this article, an improved numerical model for the simulation of the behavior of masonry infill walls subjected to earthquake loads is proposed and analyzed. First, the proposed model is presented. This is an upgrading of the equivalent bi-diagonal compression strut model, commonly used for the nonlinear behavior of infill masonry panels subjected to cyclic loads. Second, the main results of the calibration analyses obtained with two series of experimental tests are presented and discussed: one on a single frame with one story and one bay tested at the LNEC Laboratory; and the second, on a full-scale four story and three-bay frame tested at the ELSA laboratory.  相似文献   

14.
ABSTRACT

The protection of cultural heritage against earthquake induced actions is one of the main challenges the earthquake engineering science and practice are facing. This article presents a seismic assessment study on one of the most ancient colonial buildings present in Peru, the Cathedral of Lima, focusing on its towers. A historical review highlighted how these structures, together with the whole Cathedral, suffered intense damage and partial collapse during previous earthquakes. In order to identify the structure main deficiencies, both linear kinematic analyses and nonlinear static analyses have been performed. Different nonlinear finite element models have been created to evaluate the influence of the adjacent walls. Different load distributions have been compared to evaluate how simplified patterns could provide results close to load distributions taken from a modal analysis of the complex. A simple retrofit strategy, consisting on the introduction of steel ties, has also been studied as a reference. Results show good correlation between kinematic and pushover analyses. The construction, when compared to the requirements of the national code for new buildings, results significantly vulnerable, pointing out the need to accept some structural damage even after seismic retrofit.  相似文献   

15.
In this paper, an effective active control algorithm is developed for the vibration control of non-linear structural systems subjected to earthquake excitation. It is an attempt to include the non-linear characteristics of the structural behaviour throughout the entire analysis (design and validation), accounting for the eventual cumulative structural damage and energy dissipation. This is a very important factor since, in current design practice, structures are assumed to behave nonlinearly when subjected to strong ground motion. The proposed algorithm focusses on the instantaneous optimal control approach for the development of the control algorithm where the nonlinearities are brought into the analysis through a non-linear state vector and a non-linear open loop term. A performance index that is quadratic in the control force and in the non-linear states and is subjected to a non-linear constraint equation, is minimised at every time step. The effectiveness of the proposed non-linear instantaneous optimal control (NIOC) strategy is critically evaluated in comparison with currently available active control techniques. Numerical simulation results indicate that the proposed approach provides a significant reduction of the peak response quantities, such as maximum response deformation, maximum response acceleration, ductility of the system, associated with a reduced maximum control force.  相似文献   

16.
This article presents a design methodology for seismic upgrading of existing reinforced concrete (RC) buildings. The methodology is based on the modification of the deflected shape of the structure so as to achieve a near-uniform distribution of interstorey drift along the building height, thereby eliminating damage localization. Yield Point Spectra are utilized for the definition of demand and a direct displacement-based design approach is implemented. The fundamental steps of the method are described in detail, including a systematic evaluation of assumptions and limitations. A full-scale tested structure is used as a case study for assessment and verification of the proposed methodology. Alternative retrofit scenarios are set according to target response and performance levels. The role of the target deflected response shape and its influence on the outcome of the retrofit strategy is investigated. The viability of the alternative retrofit scenarios is studied for different ground motions including near-fault earthquake records.  相似文献   

17.
This paper shows the results of two passive experiments carried out at the European Volvi test site where a scaled building has been constructed. The first experiment was performed to study the motion of the structure excited by two small earthquakes. For one month, six strong-motion recorders were installed within the structure, at the top and at the basement. The analysis of the deformation of the structure has been assessed by computing the spectral ratio between the top and the bottom, with a special focus on soil-structure interaction. An analytical model was then proposed to reproduce the structure and soil-structure system behaviour. The soil-structure interaction was accounted for by using impedance functions. During the second experiment, we concentrated our efforts on the effect of the building vibration on the surface ground motion. An explosive shot was fired and several strong-motion recorders were installed on the ground close to the structure that allowed us to clearly identify a monochromatic wave coming from the building, in the time and frequency domains. This experiment allows us to demonstrate the non-negligible effect of the soil-structure-soil interaction that may disturb the surrounding ground motion.  相似文献   

18.
Earthquake damage to light-frame wood buildings is a major concern for North America because of the volume of this construction type. In order to estimate wood building damage using synthetic ground motions, we need to verify the ability of synthetically generated ground motions to simulate realistic damage for this structure type. Through a calibrated damage potential indicator, four different synthetic ground motion models are compared with the historically recorded ground motions at corresponding sites. We conclude that damage for sites farther from the fault (>20 km) is under-predicted on average and damage at closer sites is sometimes over-predicted.  相似文献   

19.
Abstract

The reconstruction and conservation of buildings in Pergamon has been an important aim of the excavations of the German Archaeological Institute Istanbul over the last twenty years. The paper discusses the structure known as Building Z situated about halfway up the slope to the acropolis of Pergamon on a rise between the terrace of the Sanctuary of Demeter and the precinct of the Temple of Hera. Although the southern fringes of this Hellenistic building were discovered in 1909, digging here was soon abandoned due to the very poor preservation of the walls. In 1990, a trench of the 'City Excavations' revealed the northern part of the building. The well-preserved Roman mosaic pavements and other remains found here — eventually exposing the best preserved examples of interior decoration yet discovered in the ancient city of Pergamon — prompted the construction of a shelter open to visitors. The construction of this shelter began in 1996 and was completed in 2004. The roofed area covers only the northern part of the former ancient building. The modern roof construction, on steel-trussed girders above the walls, has been deliberately designed as an independent unit.  相似文献   

20.
Over the past ten years, the development of analytical procedures to accurately evaluate the seismic performance of existing buildings has gathered the attention of researchers. This has resulted in the publication of several standards, which, however, inadequately cover the issue of retrofit strategy selection. In the present article, a procedure that allows a comparison of available strategies in order to select the optimum solution for an existing deficient building is proposed. The procedure is based on calculating the pushover curve for the unstrengthened structure. A capacity spectrum is then estimated assuming different retrofit scenarios, which is then used for the evaluation of the strategies. The latter is based on criteria that assess the main structural system characteristics and how each solution benefits them. The final step of the procedure introduces simplified rules that allow the approximate design of each retrofit solution, which allows the evaluation of their applicability. The proposed procedure was applied to two idealized buildings with different structural systems. Results obtained indicate that less effective or inapplicable rehabilitation strategies were properly detected. Thus, the results were considered acceptable in terms of identifying the possible optimum strategy, which, however, should be verified with a detailed design of the retrofit system.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号