首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A constitutive model for predicting the cyclic response of reinforced concrete structures is proposed. The model adopts the concept of a smeared crack approach with orthogonal fixed cracks and assumes a plane stress condition. Predictions of the model are compared firstly with existing experimental data on shear walls which were tested under monotonic and cyclic loading. The same model is then used in the finite element analysis of a complete shear wall structure which was tested under a large number of cyclic load reversals due to earthquake loading at NUPEC's Tadotsu Engineering Laboratory. Two different finite element approaches were used, namely a two-dimensional and a three-dimensional representation of the test specimen. The ability of the concrete model to -reproduce the most important characteristics of the dynamic behaviour of this type of structural element was evaluated by comparison with available experimental data. The numerical results showed good correlation between the predicted and the actual response, global as well as local response being reasonable close to the experimental one.  相似文献   

2.
A system identification framework is proposed to investigate the nonlinear dynamic response of massive earth dams using the seismic motion recorded by a sparse array of accelerometers. The framework includes a methodical step of nonparametric analyses to characterize the involved loading conditions and response mechanisms. This nonparametric step provides essential information to reduce the indeterminacy of the associated parametric identificatin problem and ensure a proper model selection, calibration, and validation. The proposed framework was applied to the Long Valley earth dam (California) and benchmarked using records of a series of 1980 earthquakes. This article presents the conducted correlation, spectral motion reconstruction, and nonparametric stress-strain analyses. These analyses revealed a complex three-dimensional dynamic response marked by non uniform boundary conditions and a shear stress-strain behavior slightly less nonlinear than what was observed in triaxial tests of soil samples taken from the dam core.  相似文献   

3.
Review of older non seismically detailed reinforced concrete building collapses shows that most collapses are triggered by failures in columns, beam-column joints, and slab-column connections. Using data from laboratory studies, failure models have previously been developed to estimate loading conditions that correspond to failure of column components. These failure models have been incorporated in nonlinear dynamic analysis software, enabling complete dynamic simulations of building response including component failure and the progression of collapse. A reinforced concrete frame analytical model incorporating column shear and axial failure elements was subjected to a suite of near-fault ground motions recorded during the 1994 Northridge earthquake. The results of this study show sensitivity of the frame response to ground motions recorded from the same earthquake, at sites of close proximity, and with similar soil conditions. This suggests that the variability of ground motion from site to site (so-called intra-event variability) plays an important role in determining which buildings will collapse in a given earthquake.  相似文献   

4.
The dynamic interaction of pile foundations, embedded in a horizontally stratified soil profile, with superstructures under low to moderate earthquake excitation can be handled in different ways. In this article, the soil-pile-superstructure dynamic interaction problem has been investigated using the coupled finite element-boundary element method. Comparison with shaking table experiments of a small scale model pile shows a good correlation with the proposed method in terms of the kinematic response of pile foundations and the structural response. A parametric study of the proposed model has yielded important results essentially concerning the amplification factors of the pile foundation and the superstructure.  相似文献   

5.
Performance-based earthquake engineering, developed over the last decades for the design and assessment of other structures, can also be applied for masonry structures if the particularities of masonry are incorporated into the procedure. According to this methodology, structural performance can be assessed according to damage states which are identified through displacement/damage indicators. While various methods for the identification of limit states from the results of nonlinear static analyses exist, the identification of damage states from the results of nonlinear dynamic analyses is still uncertain. This article investigates a number of criteria allowing to identify the attainment of significant limit states from the results of time history analyses, in terms of appropriately identified response quantities. These criteria are applied to five building prototypes and their results are compared. A comparison with the limit states derived from nonlinear static analyses is also made.  相似文献   

6.
In this paper the Author proposes a damage model for the analysis of masonry plates and shells, which is based on an improvement of a previous constitutive model. The modifications introduced, connected to the head joint damage, allow us to study the influence of masonry texture on the damage modes once the mechanical characteristics of the elements constituting the masonry and the results of tests on simple assemblages are known. Having a nonlinear constitutive model is certainly one of the basic elements for understanding the damage mechanisms in masonry buildings. If, in fact, an elastic-linear constitutive model may be used under normal loading conditions, in critical situations it is necessary to model the damage and the dissipation mechanisms that occur between the elements, stone (brick) and mortar, in correlation with their characteristics and kind of masonry. To validate the model a comparison is made between the numerical and experimental results, in the case of tests available in the literature in masonry panels subjected to out-of plane loading and in a real structure through the observation of the damage in Umbria (Italy) surveyed after the 1997 earthquake.  相似文献   

7.
ABSTRACT

This article presents a study on the out-of-plane response of two masonry structures without box behavior tested in a shaking table. Two numerical approaches were defined for the evaluation, namely macro-modeling and simplified micro-modeling. As a first step of this study, static nonlinear analyses were performed for the macro models in order to assess the out-of-plane response of masonry structures due to incremental loading. For these analyses, mesh size and material model dependency was discussed. Subsequently, dynamic nonlinear analyses with time integration were carried out, aiming at evaluating the collapse mechanism and at comparing it to the experimental response. Finally, nonlinear static and dynamic analyses were also performed for the simplified micro models. It was observed that these numerical techniques correctly simulate the in-plane response. The collapse mechanism of the stone masonry model is in good agreement with the experimental response. However, there are some inconsistencies regarding the out-of-plane behavior of the brick masonry model, which required further validation.  相似文献   

8.
9.
To fulfill a displacement-based design or response prediction for nonlinear structures, the concept of equivalent linearization is usually applied, and the key issue is to derive the equivalent parameters considering the characteristics of hysteretic model, ductility level, and input ground motions. Pinching hysteretic structures subjected to dynamic loading exhibit hysteresis with degraded stiffness and strength and thus reduced energy dissipation. In case of excitation of near-fault earthquake ground motions, the energy dissipation is further limited due to the short duration of vibration. In order to improve the energy dissipation capability, viscous-type dampers have been advantageously incorporated into these types of structures. Against the viscously damped pinching hysteretic structure under the excitation of near-fault ground motions, this study aims to develop a seismic response estimation method using an equivalent linearization technique. The energy dissipation of various hysteretic cycles, including stationary hysteretic cycle, amplitude expansion cycle, and amplitude reduction cycle, is investigated, and empirical formulas for the equivalent damping ratio is proposed. A damping modification factor that accounts for the near-fault effect is introduced and expanded to ensure its applicability to structures with damping ratios less than 5%. An approach for estimating the maximum displacement of a viscously damped pinching hysteretic structure, in which the pinching hysteretic effect of a structure and the near-fault effect of ground motions are considered, is developed. A time history analysis of an extensive range of structural parameters is performed. The results confirm that the proposed approach can be applied to estimate the maximum displacement of a viscously damped pinching hysteretic structure that is subjected to near-fault ground motions.  相似文献   

10.
A simple stick model is presented for the inelastic seismic analysis in 3D of two-way eccentric multistory RC buildings. It has 3 DoFs per floor, point hinges at the ends of the vertical elements connecting floors, elastic story stiffness derived from the corresponding story force-interstory deformation relations of the elastic 3D structure under inverted-triangular floor loading (by torques for torsional stiffness, by horizontal forces for the lateral ones), story yield forces derived from the total resistant shear of the story vertical elements, but no coupling between lateral and torsional inelasticity. It is evaluated on the basis of comparisons of response histories of floor displacements to those from full nonlinear models in 3D of four actual buildings. Alternative locations of the story vertical element with respect to the floor mass center are examined: (a) the floor “center of twist” of the elastic 3D building under inverted-triangular floor torques; (b) the story “effective center of rigidity,” through which application of inverted triangular lateral forces does not induce twisting of floors; (c) the centroid of the secant stiffness of the story vertical members at yielding and (d) the centroid of the lateral force resistance of story vertical elements. Among alternatives (a)–(d), the floor “center of twist” provides the best agreement with floor displacement response-histories from full 3D nonlinear models. This means that the static eccentricity that matters for torsional response may be taken as that of the floor “center of twist.” The center of resistance comes up as the second-best choice.  相似文献   

11.
The seismic response of bridges is affected by a number of modeling considerations, such as pier embedment, buried pile caps, seat-type abutments, pounding, bond slip and architecturally flared part of piers, and loading considerations, such as non-uniform ground excitations and orientation of ground motion components, which are not readily addressed by design codes. This article addresses a methodology for the nonlinear static and dynamic analysis of a tall, long-span, curved, reinforced-concrete bridge, the Mogollon Rim Viaduct. Various modeling scenarios are considered for the bridge components, soil-structure interaction system, and materials, i.e., concrete and reinforcing steel, covering all its geotechnical and structural aspects based on recent advances in bridge engineering. Various analysis methodologies (nonlinear static pushover, time history response to uniform and spatially variable seismic excitations, and incremental dynamic analyses) are performed. For the dynamic analyses, a suite of nine earthquake accelerograms are selected and their characteristics are investigated using seismic intensity parameters. A recently developed approach for the generation of non-uniform seismic excitations, i.e., spatially variable simulations conditioned on the recorded time series, is used. Methods for the evaluation of structural performance are discussed and their limitations addressed. The numerical results of the seismic assessment of the Mogollon Rim Viaduct are presented in the companion article (Part II). The sensitivity of the bridge response to the adopted modeling, loading and analyzing strategies, as well as the correlation between structural damage and seismic intensity parameters are examined in detail.  相似文献   

12.
Ground-supported steel tanks experienced extensive damage in past earthquakes. The failure of tanks in earthquakes may cause severe environmental damage and economic losses. This study deals with the evaluation of the elastic buckling of above-ground steel tanks anchored to the foundation due to seismic shaking. The proposed nonlinear static procedure is based on the capacity spectrum method (CSM) utilized for the seismic evaluation of buildings. Different from the standard CSM, the results are not the base shear and the maximum displacement of a characteristic point of the structure but the minimum value of the horizontal peak ground acceleration (PGA) that produces buckling in the tank shell. Three detailed finite element models of tank-liquid systems with height to diameter ratios H/D of 0.40, 0.63, and 0.95 are used to verify the methodology. The 1997 UBC design spectrum and response spectra of records of the 1986 El Salvador and 1966 Parkfield earthquakes are used as seismic demand. The estimates of the PGA for the occurrence of first elastic buckling obtained with the proposed nonlinear static procedure were quite accurate compared with those calculated with more elaborate dynamic buckling studies. For all the cases considered, the proposed methodology yielded slightly smaller values of the critical PGA for the first elastic buckling compared to the dynamic buckling results.  相似文献   

13.
A 16-story building under construction in Bucharest has been designed according to the provisions of EC2 and EC8, using elastic spectral modal analysis. Considering that the building is torsionally sensitive in the nonlinear range, it was further checked and verified using nonlinear dynamic and static procedures, using a detailed space-frame model. Specifically, time-history analysis for seven different excitations, as well as respective inelastic static analysis taking into account torsional effects were performed. The results are examined regarding structural (global) and member (local) response and various issues concerning the adequacy of the original elastic design and the applicability of advanced analysis methods are discussed.  相似文献   

14.
故宫灵沼轩是我国最早建造的钢铁-砌体组合结构之一,具有重要的历史、艺术和科学价值。为了评估灵沼轩在地震作用下的结构安全状况,建立了灵沼轩结构的三维有限元模型,并对其进行了动力特性和地震时程分析,得出了其固有频率、模态振型、地震位移响应和地震应力响应。结果表明:灵沼轩整体结构布置对称性较高,扭转刚度较大,对抗震较为有利;在8度多遇地震、设防地震和罕遇地震作用下,灵沼轩的金属结构部分及砌体结构部分的顶点位移和层间位移角均符合现行规范要求,砌体结构部分的第三主应力响应均小于材料的抗压强度,不存在压溃风险。在8度多遇地震和设防地震作用下,砌体结构部分的第一主应力响应均小于材料的抗拉强度,结构不会发生拉裂。但在8度罕遇地震作用下,砌体结构的部分位置拉应力超过材料的抗拉强度,这些位置存在开裂危险。最后,综合动力特性和抗震性能分析的结果,提出了灵沼轩的抗震加固建议。  相似文献   

15.
This study adopts a random procedure in the evaluation of the effect of the rotational component of earthquake on the accidental eccentricity of symmetric and asymmetric buildings. The spectral density function of the rotational component of earthquake acceleration (about the vertical axis) is obtained on the basis of the spectral density function of the horizontal component of earthquake acceleration. The rotational component of an earthquake can increase the response of the structure. The degree of the increase is highly dependent upon the dynamic characteristics of the system and the rotational component of the earthquake. To bring this increase under consideration, seismic codes represent a parameter referred to as accidental eccentricity, as a part of the design eccentricity. The purpose of the present study is to estimate the value of this increase and to make appropriate suggestions based on frequency domain analysis.  相似文献   

16.
The seismic assessment of special bridges, even under the hypothesis of full knowledge of site conditions, structural characteristics, and seismic activity at their location, is not an easy and straightforward task due to the complexities and uncertainties related to the finite-element modeling approaches, structural loading scenarios, and seismic analysis methodologies. In this article, a series of nonlinear static and dynamic finite-element analyses on the Mogollon Rim Viaduct are performed with consideration of both uniform and conditionally simulated non-uniform seismic motions. The failure modes of the bridge using different numerical modeling approaches are discussed, and the degree of sensitivity of its response to the different seismic assessment strategies is evaluated. The effect of the multi-component, multi-support and multi-directional excitations of ground motions on the design and response are studied, and the pros and cons of the commonly used structural analysis methodologies of bridges are also addressed. The numerical results of the present study provide a deeper insight into the nonlinear behavior of curved reinforced-concrete bridges, and suggest practice-oriented approaches for their seismic assessment.  相似文献   

17.
In this article, the influence of nonlinear behavior of multiple degree of freedom (MDOF) primary structures on floor response spectra is investigated by means of simple structural models. The cases of shear beam type as well as of capacity-designed plane frames were studied. It is shown that, in general, but not always, nonlinearity of the primary structure has a beneficial effect on floor spectra. However, higher mode response may be amplified due to nonlinear behavior. The issue of a one story structure exhibiting torsionnal response has also been addressed and some important properties are highlighted.  相似文献   

18.
The present article focuses on a nonlinear static procedure (NSP) for a multi-story asymmetric frame building with regular elevation subjected to bi-directional ground motion. In this procedure, two simplified models—an equivalent single-story model and an equivalent single-degree-of-freedom (SDOF) model—are used to predict the peak response of multi-story asymmetric buildings. The peak response is predicted through pushover analysis of an equivalent single-story model considering the effect of bi-directional excitations and an estimation of the nonlinear response of equivalent SDOF models. The predicted results are compared with the nonlinear dynamic analysis results, and satisfactory predictions can be obtained by the proposed procedure.  相似文献   

19.
Abstract

A summary of dynamic measurements are presented that illustrate relations between linear seismic demand and true nonlinear response of unreinforced masonry buildings with flexible diaphragms and rocking piers subjected to a series of simulated earthquake motions.  相似文献   

20.
A simplified analysis procedure for evaluating the nonlinear seismic responses of tall reinforced concrete (RC) buildings is examined in this study. It is called the Uncoupled Modal Response History Analysis (UMRHA) procedure. It can be viewed as an extended version of the classical modal analysis procedure, where the nonlinear response of each vibration mode is first computed, and they are later on combined into the total response of the structure. The procedure requires the knowledge of the modal hysteretic behavior, which can be obtained from a cyclic modal pushover analysis. The responses of four tall buildings in Bangkok to distant large earthquakes are computed by this procedure and compared with those obtained from the Nonlinear Response History Analysis (NLRHA) procedure. These four buildings have different heights—varying from 20 to 44 stories, different configurations of floor plan, and different arrangement of RC walls. The comparison shows that the UMRHA procedure is able to accurately compute the story shears and story overturning moments, floor accelerations, and inter-story drifts of all these tall buildings. The required computational effort is also extremely low compared to that of the NLRHA procedure. Moreover, since the UMRHA procedure computes the response of each individual vibration mode, it provides more understanding and insight into the complex nonlinear seismic responses of these tall buildings.  相似文献   