首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
ABSTRACT

The paper analyzes the static behavior and the seismic vulnerability of the “San Francesco ad Alto” building in Ancona (Italy), which is currently used as a Regional Headquarter of the Marche Region by the Italian Army and was formerly a monastery. The global static structural behavior and the dynamic properties have been evaluated using the Finite Element modeling technique, in which the nonlinear behavior of masonry has been taken into account by proper constitutive laws. The concepts of homogenized material and smeared cracking are used to evaluate the capacity of the monastery to withstand lateral loads together with the expected demands resulting from seismic actions (N2 method), using a nonlinear static analysis (pushover). The comparison of seismic demand and capacity confirms the susceptibility of these types of buildings to extensive damage and collapse, as frequently observed in similar buildings. This paper aims to point out that advanced numerical analyses can offer significant information on the understanding of the actual structural behavior of historical buildings. It is believed that the methodology and the overall conclusions of this case study are valid for many historical monasteries in Europe.  相似文献   

2.
A simple stick model is presented for the inelastic seismic analysis in 3D of two-way eccentric multistory RC buildings. It has 3 DoFs per floor, point hinges at the ends of the vertical elements connecting floors, elastic story stiffness derived from the corresponding story force-interstory deformation relations of the elastic 3D structure under inverted-triangular floor loading (by torques for torsional stiffness, by horizontal forces for the lateral ones), story yield forces derived from the total resistant shear of the story vertical elements, but no coupling between lateral and torsional inelasticity. It is evaluated on the basis of comparisons of response histories of floor displacements to those from full nonlinear models in 3D of four actual buildings. Alternative locations of the story vertical element with respect to the floor mass center are examined: (a) the floor “center of twist” of the elastic 3D building under inverted-triangular floor torques; (b) the story “effective center of rigidity,” through which application of inverted triangular lateral forces does not induce twisting of floors; (c) the centroid of the secant stiffness of the story vertical members at yielding and (d) the centroid of the lateral force resistance of story vertical elements. Among alternatives (a)–(d), the floor “center of twist” provides the best agreement with floor displacement response-histories from full 3D nonlinear models. This means that the static eccentricity that matters for torsional response may be taken as that of the floor “center of twist.” The center of resistance comes up as the second-best choice.  相似文献   

3.
A very useful tool for the preliminary design of structures is the elastic demand spectrum that can be used in the capacity spectrum method. A pseudo-acceleration relationship has to be assumed when constructing a demand spectrum. This assumption results in large errors for long period structures with large damping ratios and the conventional demand spectra require a substitute elastic structure. In the present study, the conventional demand spectra are extended to bi-linear models. Pseudo-acceleration is still assumed but results in acceptably small errors, when a constant viscous damping coefficient for a single-degree-of-freedom (SDF) structure is calculated from the tangent stiffness and the damping ratio is set at 5% in both elastic and yield phases. For nonlinear structures, tangent stiffness dependency of damping force could be acceptable because energy absorption is primarily the result of structural nonlinear deformation. To extend the conventional demand spectra to a bi-linear model, effective period calculated from the secant stiffness has to be used. The use of effective period introduces no approximation because the peak displacement of the SDF structure is computed from nonlinear analysis in the time domain. The method presented in this study is also valid if damping coefficient proportional to initial elastic spectra is used. In this case, the pseudo-acceleration is defined as the base shear coefficient that is required to produce the peak displacement of the SDF structure in a static manner. We present demand spectra of bi-linear models for a number of near-source records from large earthquakes, and spectral ratios of two horizontal components. The effects of different types of ground motion on the response reduction factor due to inelastic deformation are investigated.  相似文献   

4.
The present article focuses on a nonlinear static procedure (NSP) for a multi-story asymmetric frame building with regular elevation subjected to bi-directional ground motion. In this procedure, two simplified models—an equivalent single-story model and an equivalent single-degree-of-freedom (SDOF) model—are used to predict the peak response of multi-story asymmetric buildings. The peak response is predicted through pushover analysis of an equivalent single-story model considering the effect of bi-directional excitations and an estimation of the nonlinear response of equivalent SDOF models. The predicted results are compared with the nonlinear dynamic analysis results, and satisfactory predictions can be obtained by the proposed procedure.  相似文献   

5.
A procedure is presented to extend the static torsional provisions of the Eurocode 8 (EC8) to asymmetrical multi-storey buildings. It is shown that even if the conditions in Annex A of EC8 are satisfied, the static torsional provision will not be effective to compensate for the effect of torsion unless the building possesses a minimum level of torsional stiffness. By means of examples, it is shown that this minimum torsional stiffness condition can be specified in the Code using the mean stiffness radius of gyration of the building calculated based on the proposed procedure as an index.  相似文献   

6.
Ground-supported steel tanks experienced extensive damage in past earthquakes. The failure of tanks in earthquakes may cause severe environmental damage and economic losses. This study deals with the evaluation of the elastic buckling of above-ground steel tanks anchored to the foundation due to seismic shaking. The proposed nonlinear static procedure is based on the capacity spectrum method (CSM) utilized for the seismic evaluation of buildings. Different from the standard CSM, the results are not the base shear and the maximum displacement of a characteristic point of the structure but the minimum value of the horizontal peak ground acceleration (PGA) that produces buckling in the tank shell. Three detailed finite element models of tank-liquid systems with height to diameter ratios H/D of 0.40, 0.63, and 0.95 are used to verify the methodology. The 1997 UBC design spectrum and response spectra of records of the 1986 El Salvador and 1966 Parkfield earthquakes are used as seismic demand. The estimates of the PGA for the occurrence of first elastic buckling obtained with the proposed nonlinear static procedure were quite accurate compared with those calculated with more elaborate dynamic buckling studies. For all the cases considered, the proposed methodology yielded slightly smaller values of the critical PGA for the first elastic buckling compared to the dynamic buckling results.  相似文献   

7.
This article describes a simplified procedure for estimating the seismic sidesway collapse capacity of frame building structures incorporating linear viscous dampers. The proposed procedure is based on a robust database of seismic peak displacement responses of viscously damped nonlinear single-degree-of-freedom systems for various seismic intensities and uses nonlinear static (pushover) analysis without the need for nonlinear time history dynamic analysis. The proposed procedure is assessed by comparing its collapse capacity predictions on 272 different building models with those obtained from incremental dynamic analyses. A straightforward collapse capacity-based design procedure is also introduced for structures without extreme soft story irregularities.  相似文献   

8.
ABSTRACT

Several architectural configurations of unreinforced masonry residential buildings are designed according to the different methods proposed in the Italian code: rules for the so-called simple masonry buildings, linear and nonlinear static analyses. Always complying with code requirements, for each building-site combination, the design was made, as much as possible, without an excessive margin of safety. The different design methods provided buildings with very different levels of safety, being linear static analysis largely overconservative with respect to the nonlinear static approach. These buildings were then analyzed in the companion paper.  相似文献   

9.
A complete structural analysis of the bell tower of Santa Maria del Carmine in Naples (Italy) has been developed by using a 3D FE model based on the results of detailed experimental investigations in situ. Linear analysis for gravity loads, linear modal analysis, and nonlinear static analysis (Push Over) were carried out in order to assess the seismic capacity of the structure. A check of local out-of-plane failure mechanisms was also performed to verify if the structure is able to attain a global behavior. Problems and solutions related to the different methods are presented and discussed.  相似文献   

10.
Masonry building aggregates are large parts of the Italian building heritage often designed without respecting seismic criteria. The current seismic Italian code does not foresee a clear calculation method to predict their static nonlinear behavior. For this reason, in this article a simple methodology to forecast the masonry aggregate seismic response has been set up. The implemented procedure has been calibrated on the results of two FEM structural analysis programs used to investigate three masonry building compounds. As a result, a design chart used to correctly predict the base shear of aggregate masonry units starting from code provisions has been set up.  相似文献   

11.
Two analytical models for unreinforced masonry (URM) buildings are proposed with the aim to simulate their seismic response and to estimate corresponding vulnerability functions. The proposed models are implemented in SAP 2000 nonlinear software to obtain capacity curve parameters for representative Indian URM buildings, based on a field survey and statistical analysis. Vulnerability functions are estimated using the obtained capacity curves. Damage Probability Matrices (DPMs) are obtained using the approximate PGA-intensity correlation relationship as per Indian seismic building code and are compared with the commonly used intensity scales and empirical damage data observed after the 2001 Bhuj earthquake.  相似文献   

12.
Performance-based earthquake engineering, developed over the last decades for the design and assessment of other structures, can also be applied for masonry structures if the particularities of masonry are incorporated into the procedure. According to this methodology, structural performance can be assessed according to damage states which are identified through displacement/damage indicators. While various methods for the identification of limit states from the results of nonlinear static analyses exist, the identification of damage states from the results of nonlinear dynamic analyses is still uncertain. This article investigates a number of criteria allowing to identify the attainment of significant limit states from the results of time history analyses, in terms of appropriately identified response quantities. These criteria are applied to five building prototypes and their results are compared. A comparison with the limit states derived from nonlinear static analyses is also made.  相似文献   

13.
ABSTRACT

Historical centers are always composed of masonry building aggregates often designed without respecting seismic design criteria. The current seismic Italian code does not foresee a clear calculation method to predict their static nonlinear behavior. For this reason, in this article the seismic response of structural units into masonry aggregates has been predicted through a simplified modeling approach. The implemented procedure has been calibrated on the results of a numerical model performed by using the Equivalent Frame Method (EFM), implemented within a Finite Element Method (FEM) calculation program, used to investigate a basic building compound representative of the constructive techniques developed in the past decades in the Southern Italy.

First, the whole aggregate has been modeled and analyzed in the nonlinear static field in order to evaluate the seismic behavior of both intermediate and head structural units.

Later on, the seismic response of these structural units, considered as isolated structures, has been assessed by considering in simplified way their position in the aggregate, as well as the influence of other constructions.

Finally, the achieved results on the above single analysis cases have been compared with those deriving from the investigation of the whole building compound, allowing to confirm the effectiveness of the proposed novel analysis procedure.  相似文献   

14.
15.
ABSTRACT

This study investigates the seismic response of reinforced concrete buildings designed according to the current Italian building code. Number of stories, site hazard, presence and distribution of masonry infill panels, and type of lateral resisting system are the key investigated parameters. The main issues related to design and modeling are discussed. Two Limit States are considered, namely Global Collapse and Usability-Preventing Damage. The main aim of the study is a comparison between the seismic response of the buildings, investigated through nonlinear static and dynamic analyses. Irregularity in the distribution of infill panels and site hazard emerge as the most influential parameters.  相似文献   

16.
This article presents the comparison among different nonlinear seismic analysis methods applied to masonry buildings, i.e., pushover analyses with invariant lateral force distributions, adaptive pushover analysis and nonlinear dynamic analysis. The study focuses on the influence of lateral force distribution on the results of the pushover analysis. Two simple benchmark case studies are considered for the purpose of the research, i.e., a four-wall masonry building prototype without floor rigid diaphragms and a two-wall system with a cross-vault. The comparative study offers a useful review of pushover analysis methods for masonry structures and shows advantages and possible limitations of each approach.  相似文献   

17.
The general trends of the inelastic behaviour of plan-asymmetric structures have been studied. Systems with structural elements in both orthogonal directions and bi-axial eccentricity were subjected to bi-directional excitation. Test examples include idealised single-storey and multi-storey models, and a three-storey building, for which test results are available. The response in terms of displacements was determined by nonlinear dynamic analyses. The main findings, limited to fairly regular and simple investigated buildings, are: (a) The amplification of displacements determined by elastic dynamic analysis can be used as a rough, and in the majority of cases conservative estimate in the inelastic range, (b) Any favourable torsional effect on the stiff side, which may arise from elastic analysis, may disappear in the inelastic range. These findings can be utilised in the approximate pushover-based seismic analysis of asymmetric buildings, e.g. in the N2 method. It is proposed that the results obtained by pushover analysis of a 3D structural model be combined with the results of a linear dynamic (spectral) analysis. The former results control the target displacements and the distribution of deformations along the height of the building, whereas the latter results define the torsional amplifications. The proposed approach is partly illustrated and evaluated by test examples.  相似文献   

18.
ABSTRACT

In this study, industrial single-story RC precast buildings are investigated. Twenty-four case studies have been considered, in which the column height, the beam spans and the seismic hazard level are varied. The seismic design of the selected case studies is performed according to the Italian building code and additional technical documentation. Three-dimensional nonlinear models are defined to perform static and dynamic analyses for the seismic assessment of the selected case studies. Demand/capacity ratios in terms of the selected engineering demand parameters are computed for ten increasing values of the seismic input return period.  相似文献   

19.
The seismic assessment of special bridges, even under the hypothesis of full knowledge of site conditions, structural characteristics, and seismic activity at their location, is not an easy and straightforward task due to the complexities and uncertainties related to the finite-element modeling approaches, structural loading scenarios, and seismic analysis methodologies. In this article, a series of nonlinear static and dynamic finite-element analyses on the Mogollon Rim Viaduct are performed with consideration of both uniform and conditionally simulated non-uniform seismic motions. The failure modes of the bridge using different numerical modeling approaches are discussed, and the degree of sensitivity of its response to the different seismic assessment strategies is evaluated. The effect of the multi-component, multi-support and multi-directional excitations of ground motions on the design and response are studied, and the pros and cons of the commonly used structural analysis methodologies of bridges are also addressed. The numerical results of the present study provide a deeper insight into the nonlinear behavior of curved reinforced-concrete bridges, and suggest practice-oriented approaches for their seismic assessment.  相似文献   

20.
This study investigates the effectiveness of the modal analysis using three-degree-of freedom (3DOF) modal equations of motion to deal with the seismic analysis of two-way asymmetric elastic systems with supplemental damping. The 3DOF modal equations of motion possessing the non proportional damping property enable the two modal translations and one modal rotation to be non proportional in an elastic state. The simple approximation method is to use the single degree-of-freedom (SDOF) modal equations of motion, which are obtained by neglecting the off-diagonal elements of the transformed damping matrix. One, one-story and one, three-story non proportionally damped two-way asymmetric buildings under the excitation of bi-directional seismic ground motions are analyzed. The analytical results are obtained by using the proposed method, noted simple approximation method, and direct integration of the equation of motion. It is seen that the proposed method can significantly improve the accuracy of the analytical results compared with those obtained by using the simple approximation method. Moreover, the proposed method does not substantially increase the computational efforts.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号