首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A full-scale shake table test is conducted to assess the seismic response characteristics of a 23 m high wind turbine. Details of the experimental setup and the recorded dynamic response are presented. Based on the test results, two calibrated beam-column finite element models are developed and their characteristics compared. The first model consists of a vertical column of elements with a lumped mass at the top that accounts for the nacelle and the rotor. Additional beam-column elements are included in the second model to explicitly represent the geometric configuration of the nacelle and the rotor. For the tested turbine, the experimental and numerical results show that the beam-column models provide useful insights. Using this approach, the effect of first-mode viscous damping on seismic response is studied, with observed experimental values in the range of 0.5–1.0% and widely varying literature counterparts of 0.5–5.0%. Depending on the employed base seismic excitation, damping may have a significant influence, reinforcing the importance of more accurate assessments of this parameter in future studies. The experimental and modeling results also support earlier observations related to the significance of higher modes, particularly for the current generation of taller turbines. Finally, based on the outcomes of this study, a number of additional experimental research directions are discussed.  相似文献   

2.
The results of an experimental study on the effect of the joints between the blocks on the ultimate bearing capacity of a multi-drum column loaded to centric vertical force and horizontal force in the middle of its height are shown. The column is approximately 2.5 m high, with one hinge at the top and another hinge at the bottom. Four types of joints between the blocks were considered: a dry joint (column C-DJ) and joints with stone powder (column C-SPJ), lead (column C-PBJ), and epoxy (column C-EPJ). The applied vertical and horizontal forces, horizontal displacement, vertical strains, and horizontal circumferential strains in the middle of the column height, as well as shortening of the column, were measured. Under axial compression, ratios between the ultimate load bearing capacities of tested columns were C-EPJ: C-DJ: C-SPJ: C-PBJ = 1: 0.68: 0.59: 0.51. The bearing capacity of the tested columns with regard to the horizontal force depended on the level of the applied centric compression force. Columns with soft joints (C-PBJ, C-SPJ) had the largest shortening and the largest horizontal displacements for the equal forces.  相似文献   

3.
This work concerns the stability of unreinforced masonry slender circular cross-sectional columns subjected to their own weight and eccentric vertical load. Cantilever columns are examined, considering that the material has infinitely linear elastic behavior in compression and has no tensile strength. For the analysis, an existing numerical model and solution procedure developed for the stability analysis of masonry elements with rectangular cross-section are utilized and adapted to the circular columns. For the instability of the columns, an appropriate criterion that relates the top lateral deflection to the intensity of the applied eccentric vertical load is employed. By considering a reference column, critical buckling load is obtained, behavior of the column interpreted and efficiency of the numerical model emphasized. Performing a nonlinear buckling analysis using a general purpose software on this reference column, obtained results are compared with those of the adapted procedure of the present study. Implementing parametric analyses on reference column, effects of the column slenderness, eccentricity of vertical load, elastic modulus, and self-weight on the buckling load are investigated. Presented calculation procedure provides a useful tool in order to calculate the critical loads or to check the stability of masonry circular columns.  相似文献   

4.
Self-centering ability of unbonded post-tensioned precast concrete shear walls has been attributed to the presence of post-tensioning force. However, the experimental results presented in this paper indicate that the post-tensioning force may completely die out during cyclic loading while the walls are able to retain their superior self-centering characteristic. Moreover, the analytical study presented in this article indicates that with proper configuration of end-anchorages for post-tensioned tendons, self-centering of post-tensioned walls can be achieved even when the post-tensioning force vanishes. This study also investigates the effects of tendon layout, tendon end-anchorage configuration, and external vertical load on the self-centering ability of unbonded precast concrete shear walls subjected to earthquake loading.  相似文献   

5.
In this article, experimental and finite element (FE) numerical investigations on interior wide-beam column joints are presented. The experimental research consisting of three full-scale interior wide-beam column specimens was carried out at Nanyang Technological University, Singapore to study the seismic behavior. Details of the test results are discussed to understand the specimens' seismic performance in terms of general behavior, hysteresis loops response, and strain profiles of longitudinal reinforcement. In the FE numerical study, the three-dimensional (3D) model developed is validated by comparing the analysis results with the experimental test results, which has shown a good agreement. A parametric study is performed to elucidate more information and to understand the influence of critical parameters affecting the joint behavior such as column axial load, beam anchorage ratio, and wide beam participation.  相似文献   

6.
We present mesospheric backscattered VHF echo power and wind velocity data indicating the co-existence of a threefold strongly echoing layer and a wave motion, observed on 20 September 1985 with the MU radar at Shigaraki (34.9°N, 136.1°E), Japan. The echoing layers are clearly connected with the vertical and horizontal wind perturbations due to the wave. The analysis of the wind data have shown that the wave motion is due to an internal inertia-gravity wave with the vertical and horizontal wavelengths of 6 and 400 km, respectively, and period of 5.6 h. Evaluating the atmospheric stability in the wave field with the estimated wave parameters, the echoing layers are shown to be consistent with statically stable regions generated by the wave. It is suggested from our results that Fresnel scattering is a dominant echoing mechanism for a VHF radar beam in the mesosphere, as well as in the lower stratosphere.  相似文献   

7.
This paper presents a robust mixed force and displacement control strategy for testing of base isolation bearings in real-time hybrid simulation. The mixed-mode control is a critical experimental technique to impose accurate loading conditions on the base isolation bearings. The proposed mixed-mode control strategy consists of loop-shaping and proportional-integral-differential controllers. Following experimental validation, the mixed-mode control was demonstrated through a series of real-time hybrid simulation. The experimental results showed that the developed mixed-mode control enables accurate control of dynamic vertical force on the base isolation bearings during real-time hybrid simulation.  相似文献   

8.
We analyze 375 h of Na Wind/Temperature lidar measurements of the mesopause region (≈ 80–105 km) Na density and temperature profiles on 57 nights distributed over 2 yr at Urbana, Illinois. These observations yield a high-resolution seasonal data set of gravity wave activity in the upper mesosphere. From this data, we present measurements of the Brunt-Väisälä period, the relative atmospheric density perturbations and their spectra, and the parameters of 143 quasi-monochromatic gravity waves. The direct measurement of the Brunt-Väisälä period allows accurate calculation of the horizontal velocity perturbations and vertical displacement perturbations from the density measurements. The horizontal velocity and vertical displacement vertical wave number spectrum magnitudes and indices show considerable seasonal and nightly variability. The gravity wave amplitudes, wavelengths, and observed periods exhibit systematic relationships similar to those found in previous studies, and are consistent with the MU radar measurements of intrinsic gravity wave parameters. Here, we present a detailed analysis of the observations in terms of Diffusive-Filtering Theory models of gravity wave propagation. The magnitudes of the vertical wave number spectrum, the form of the joint vertical wave number and frequency spectrum, and the systematic relationships between the monochromatic gravity wave parameters are consistent with the Diffusive-Filtering model. We compare these results with a variety of radar, lidar, and airglow observations from other sites. This observational study suggests that the complex nonlinear interactions of the gravity wave field may be modeled successfully as a diffusive damping process, where the effective diffusivity is a function of the total wave variance.  相似文献   

9.
Abstract

In view of the compendium of field evidence and supporting analysis work indicating the possible damaging effects of vertical earthquake ground motion, this paper addresses the problem of code-type vertical force calculation. In light of recent engineering seismology studies of the relationship between vertical and horizontal peak ground acceleration, the inadequacy of the 2/3-rule depicted by codes is highlighted. A simple piece-wise linear relationship is proposed and shown to represent existing strong-motion measurements adequately. Bilinear and inelastic spectra are derived and studied. It is demonstrated that net tensile forces and displacements may ensue, thus eroding the shear resistance of RC columns. A simple procedure is outlined whereby modal analysis may be employed to estimate conservatively vertical earthquake forces on buildings. Finally, areas of further exploration and refinement are identified.  相似文献   

10.
A simple stick model is presented for the inelastic seismic analysis in 3D of two-way eccentric multistory RC buildings. It has 3 DoFs per floor, point hinges at the ends of the vertical elements connecting floors, elastic story stiffness derived from the corresponding story force-interstory deformation relations of the elastic 3D structure under inverted-triangular floor loading (by torques for torsional stiffness, by horizontal forces for the lateral ones), story yield forces derived from the total resistant shear of the story vertical elements, but no coupling between lateral and torsional inelasticity. It is evaluated on the basis of comparisons of response histories of floor displacements to those from full nonlinear models in 3D of four actual buildings. Alternative locations of the story vertical element with respect to the floor mass center are examined: (a) the floor “center of twist” of the elastic 3D building under inverted-triangular floor torques; (b) the story “effective center of rigidity,” through which application of inverted triangular lateral forces does not induce twisting of floors; (c) the centroid of the secant stiffness of the story vertical members at yielding and (d) the centroid of the lateral force resistance of story vertical elements. Among alternatives (a)–(d), the floor “center of twist” provides the best agreement with floor displacement response-histories from full 3D nonlinear models. This means that the static eccentricity that matters for torsional response may be taken as that of the floor “center of twist.” The center of resistance comes up as the second-best choice.  相似文献   

11.
The flow of water along discontinuities, such as fractures or faults, is of paramount importance in understanding the hydrogeology of many geological settings. An experimental study was undertaken comprising two experiments on a 30° slip‐plane filled with kaolinite or Ball Clay gouge using a bespoke Angled Shear Rig (ASR). The gouge was initially loaded in equal step changes in vertical stress, followed by unloading of the sample in similar equal steps. This was followed by reloading to a new maximum stress, followed by unloading; the test history was therefore load‐unload‐reload‐unload (LURU). The transmissivity of the kaolinite and Ball Clay gouge showed a power‐law relationship with vertical stress. The LURU history showed considerable hysteresis, with flow effectively unchanged during unloading, even when vertical stress was close to zero. Reloading resulted in flow similar to that seen during unloading suggesting that the unloading‐reloading path is similar to the rebound‐reconsolidation line in classic soil mechanics. These observations show the importance of stress history on fracture flow; consideration of just the current stress acting upon a fracture may result in inaccuracies of predicted hydraulic flow. Once a new stress maximum was achieved the transmissivity of the fracture continued to reduce. No significant variation was seen in the flow response of kaolinite and Ball Clay gouge suggesting that the inclusion of illite and quartz did not have a significant influence on the form of the relationship between stress and flow, i.e. both described by a power‐law.  相似文献   

12.
We present the results of high-resolution observations of the vertical velocity field obtained with the EISCAT and SOUSY VHF radars near the high-latitude summer mesopause during the MAC/SINE campaign in northern Norway in 1987. The data reveal an energetic motion field with maximum amplitudes of ~ 10 m/s and characteristic periods of ~5–30 min. Motions exhibit a high degree of vertical coherence and a quasi-periodic structure, with typical durations of 5–10 cycles. Estimates of the mean vertical velocity are downward at lower levels and are near zero or positive at greater heights. The mean vertical velocity variance is found to be ~5 m2/s2, consistent with other high-latitude measurements. Frequency spectra computed for each radar are found to exhibit considerable variability, while vertical wavenumber spectra are seen to be somewhat variable in amplitude and to have slopes approaching −3 at lower wavenumbers. These results are suggestive of an energetic spectrum of gravity wave motions near the mesopause that has a large vertical flux of wave energy, that may have observed wave frequencies differing significantly from intrinsic frequencies due to Doppler shifting by large horizontal winds, and that is consistent with the separability of the frequency and wavenumber dependence of the motion spectrum and with gravity wave saturation at sufficiently small vertical scales.  相似文献   

13.
The effects of the spatial variability of ground motion (loss of coherence, wave passage, and local site conditions) on the response of isolated bridges are investigated.

Therefore, a statistical approach is adopted to represent uncertainties in both the bridge configuration and the ground motion variability. The response of isolated bridges, designed for a standard input motion, under a spatially varying ground motion, is evaluated by nonlinear time-history analyses; the system performance is measured by the displacement demand on isolators.

Results show that the phenomenon affects the structural response considerably; the demand increases for the majority of isolators, irrespective of bridge configuration.  相似文献   

14.
This article investigates the influences of the effective ground motion duration (GMD) on damping reduction factor. The GMD are associated with 25 Chi-chi earthquake ground motion records and harmonic sine wave. The study shows that damping reduction factor decreases with the increasing of the damping ratio, and decreases with the increasing of the effective duration of the ground motion and the number of cycles of harmonic excitation. A nonlinear multiple regression analysis based on the statistical mean values of the present study is employed, and a modified damping reduction factor considering the effects of GMD is suggested.  相似文献   

15.
T-shaped slender reinforced concrete (RC) structural walls are commonly used in medium-rise and high-rise buildings as part of lateral force resisting system. Compared to its popularity, experimental results on seismic performance of these walls are relatively sparse, especially for data regarding these walls in the non-principal bending directions. This article aims at providing additional experimental evidence on seismic performance of T-shaped RC structural walls. Experimental results of six T-shaped RC walls were presented. These walls resemble the structural walls found in existing buildings in Singapore and possess slightly inferior details compared to the requirements of modern design codes. The test variables were the loading direction and the axial load ratio. The experimental results were discussed in terms of the failure mechanisms, cracking patterns, hysteretic responses, curvature distributions, displacement components, and strain profiles. In addition, the experimental results were compared with methods commonly adopted in current design practice including the nonlinear section analyses, shear strength models and effective width of the tension flange. The experimental data illustrate that the shear lag effect not only was not accurately accounted for by the effective width method but also significantly affected the strength and stiffness of the tested specimens.  相似文献   

16.
Three reinforced concrete (RC) circular column specimens without an effective concrete cover were tested under constant axial compressive as well as cyclic lateral loading. The seismic behavior of the specimens under different loading paths was examined with the objective of understanding the influence of displacement history sequence on the seismic behavior of the columns in near-fault earthquakes. The influence of displacement history sequence upon the hysteretic characteristics, stiffness degradation, lateral capacity, as well as energy dissipation analysis was conducted. The hoop strains of lateral reinforcement at varied column heights under cyclic loading were attained by means of 8–16 strain gauges attached along the hoops. Additionally, the characteristics of strain distribution were investigated in the transverse reinforcement. The results of strain distribution were evaluated with Mander’s confinement stress model and the distribution around the cross section. The length of the plastic hinge at the end of the specimen was evaluated by measurement as well as the inverse analysis. Finally, the deformation of the specimen, which includes the components of shear deformation, bending deformation and bonding-slip deformation, was evaluated and successfully separated.  相似文献   

17.
The effect of excess pore pressure developed in backfill soil during earthquake is an important consideration in rotational displacement prediction of gravity quay walls. Based on Newmark’s sliding block concept and stress-based excess pore pressure model, a new method is proposed to predict the critical rotational acceleration and angular acceleration time histories considering the development process of excess pore pressure in earthquake events. Then, the rotational displacement of gravity quay walls is predicted according to the calculated angular acceleration time histories. By using the proposed method, the effects of various parameters involved in the calculation have been studied by carrying out a parameter study. Analysis results reveal that the influence of excess pore pressure on the rotational displacement of gravity quay walls with saturated backfill soil is significant, so, can not be ignored; and rotational displacement is sensitive to the magnitude of earthquake, horizontal and vertical seismic accelerations of ground motion, wall and soil friction angle, and soil relative density. When the rotation and sliding of wall occur simultaneously, rotation and sliding will be inhibited by each other.  相似文献   

18.
Comparative study of numerically and experimentally obtained seismic responses of un-reinforced masonry building supported on in-house designed un-bonded fibre reinforced elastomeric isolator (U-FREI) are presented in this article. The effectiveness of U-FREI is established very clearly in terms of controlled dynamic response of the model building. Experimental studies are carried out on a shake table with elaborate instrumentations for measurement of acceleration and displacements at different floor levels. Numerical study of the model building supported on U-FREI is carried out to compare the results with experimental investigation. Multi-linear pivot hysteretic plasticity model is used to simulate the behavior of FREI, while plate elements are used for brick-masonry walls. Experimentally obtained force-displacement curves of FREI are used for defining the properties of multi-linear model representing FREI. The dynamic responses obtained from the numerical studies are compared with those from experimental investigations. This study indicates that the seismic responses of building supported on U-FREI can be numerically evaluated with quite reasonable accuracy. A good numerical model can be judiciously used at the preliminary design stage, followed by actual testing and construction of the base isolated building.  相似文献   

19.
Reduced-scale external RC beam-column specimens with three typical deficiencies as beam weak in flexure (BWF), beam weak in shear (BWS) and column weak in shear (CWS) were tested under cyclic excitations of different frequencies, varying from 0.025–2.0 Hz. Parameters like load carrying capacity, stiffness degradation, energy dissipation, principal tensile stress were monitored for exploring the effect of rate of loading on different types of deficient beam-column connections in a holistic manner. Test results showed that the rate effect is significant in beam-column connection with BWF, while the same is not so significant in BWS and CWS specimens.  相似文献   

20.
To evaluate the strength hierarchy, three different types of exterior beam-column joint, i.e., gravity load designed, non ductile and ductile, following two different codes are considered. Strength of different components of beam-column joint, i.e., column, beam, and joint core, is individually calculated from different failure criteria. Shear strength of the joint is evaluated from softened strut and tie model. Strength hierarchy, ultimate strength, and critical failure modes of the specimens are analytically estimated and found to be well corroborated with the experimental results. The study will help in designing the earthquake resistant RC structures in a more rational way.  相似文献   