首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
This article addresses the results of a structural strengthening solution for rubble stone masonry walls. The strengthening includes inserting three-dimensional steel ties across the thickness of the walls and a 30-mm layer of air-lime and cement mortar render reinforced with glass fiber mesh (textile-reinforced mortar), on both sides of the wall. The strengthening solution was found to be efficient for rehabilitating ancient rubble stone masonry walls due to the “three-dimensional” confinement, provided by the steel wires, by offsetting the low cohesive capacity of the mortar used in the walls and thus improving the mechanical resistance and delaying the collapse mechanisms. This study is part of an experimental research program carried out in Universidade Nova de Lisboa, to evaluate structural strengthening solutions for ancient rubble stone masonry buildings. To this end, three specimens of rubble stone masonry walls without strengthening (unreinforced masonry) and other three, with the mentioned strengthening solution, were subjected to compression and shear load tests. Building materials were also tested in order to characterize physical, chemical and mechanical properties.  相似文献   

2.
Seismic vulnerability of unreinforced masonry buildings is studied by means of simplified out-of-plane collapse mechanisms that take into account connections with transversal walls. According to experimental evidence, the analysis assumes that failure is reached with a rigid body motion of a part of the facade that falls down. Two classes of mechanism are examined: the overturning of the facade due either to a vertical crack at the connection or a diagonal crack on the transversal wall, both defined resorting to a simple model of masonry fabric, viewed as a regular assembly of rigid blocks and elastic plastic joints with friction but no cohesion. The use of simplified mechanisms give rise to an explicit evaluation of the seismic resistance to changes in the geometry and in the masonry fabrics, that could be used by practising engineers. This formulation is developed for both static horizontal actions and ground velocity peak, in the belief that the latter probably gives a better approximation of seismic action, while also providing, by comparison with the results of static forces, an estimate of the behaviour factor for unreinforced masonry. Eventually, the analytical forecasts are compared with numerical results obtained by means of the distinct element method.  相似文献   

3.
ABSTRACT

Observations after strong earthquakes show that out-of-plane failure of unreinforced masonry elements probably constitutes the most serious life-safety hazard for this type of construction. Existing unreinforced masonry buildings tend to be more vulnerable than new buildings, not only because they have been designed to little or no seismic loading requirements, but also because connections among load-bearing walls and with horizontal structures are not always adequate. Consequently, several types of mechanisms can be activated due to separation from the rest of the construction. Even when connections are effective, out-of-plane failure can be induced by excessive vertical and/or horizontal slenderness of walls (length/thickness ratio). The awareness of such vulnerability has encouraged research in the field, which is summarized in this article. An outline of past research on force-based and displacement-based assessment is given and their translation into international codes is summarized. Strong and weak points of codified assessment procedures are presented through a comparison with parametric nonlinear dynamic analyses of three recurring out-of-plane mechanisms. The assessment strategies are marked by substantial scatter, which can be reduced through an energy-based assessment.  相似文献   

4.
Although the issue of the out-of-plane response of unreinforced masonry structures under earthquake excitation is well known with consensus among the research community, this issue is simultaneously one of the more complex and most neglected areas on the seismic assessment of existing buildings. Nonetheless, its characterization should be found on the solid knowledge of the phenomenon and on the complete understanding of methodologies currently used to describe it. Based on this assumption, this article presents a general framework on the issue of the out-of-plane performance of unreinforced masonry structures, beginning with a brief introduction to the topic, followed by a compact state of art in which the principal methodologies proposed to assess the out-of-plane behavior of unreinforced masonry structures are presented. Different analytical approaches are presented, namely force and displacement-based, complemented with the presentation of existing numerical tools for the purpose presented above. Moreover, the most relevant experimental campaigns carried out in order to reproduce the phenomenon are reviewed and briefly discussed.  相似文献   

5.
ABSTRACT

An experimental campaign and a numerical analysis devoted to the investigation of the out-of-plane behavior of masonry walls reinforced with Fiber Reinforced Cementitious Matrix (FRCM) are presented here. The main goal of this study is to analyze and evaluate the effectiveness of the strengthening system, by discussing failure modes and capacity of strengthened masonry walls, in order to assess their behavior under out-of-plane horizontal actions, such as, for example, seismic actions. A purposely designed experimental set-up, able to separately and independently apply an axial force and out-of-plane horizontal actions on masonry walls, was used. Experimental results are discussed and compared with the outcomes of nonlinear analyses performed on simplified finite element models of the walls. A proper evaluation of the flexural capacity of FRCM strengthened walls is the first step of the ongoing process of drawing reliable code guidelines leading to a safe design of strengthened masonry structures.  相似文献   

6.
Modern unreinforced masonry buildings with reinforced concrete slabs are often retrofitted by inserting reinforced concrete walls. The main advantages of this technique are the increase in strength and displacement capacity with respect to masonry structures. This article presents two modeling approaches for evaluating such structures: a shell-element model and a macro-element one. The objective is to formulate practical recommendations for setting up a macro-element model using as input the geometry of the structure and results from standard material tests. Structural configurations of masonry buildings, in which the insertion of reinforced concrete walls is an efficient retrofit technique, are also investigated.  相似文献   

7.
A framework for quick seismic assessment and retrofit of traditional unreinforced masonry (URM) structures is presented. The proposed methods build on simple principles of structural dynamics and are used as an alternative to detailed time-history analysis, in recognition of the prevailing need for simple and practical methods, compatible with the low-budget and the limited level of knowledge regarding materials, internal force paths, connectivity and condition of older URM structures. An objective is to identify areas in the building that are particularly susceptible to damage and for guiding the types of the required global interventions to improve seismic response. Demand and supply are expressed in terms of relative drift ratios that quantify the intensity of out-of-plane differential translation and in-plane shear distortion of masonry walls. A characteristic traditional building type of timber-laced masonry is used as a model structure for illustration of concepts. The morphology and geometry of the building correspond to a statistical sample of the actual traditional unreinforced masonry buildings (TURM) found in historical centers of many towns in the greater region of Northern Greece. The methodology is particularly useful for setting retrofit priorities and management of the collective seismic risk of historical entities.  相似文献   

8.
ABSTRACT

Earthquakes cause severe damage to masonry structures due to inertial forces acting in the normal direction to the plane of the walls. The out-of-plane behavior of masonry walls is complex and depends on several parameters, such as material and geometric properties of walls, connections between structural elements, the characteristics of the input motions, among others. Different analytical methods and advanced numerical modeling are usually used for evaluating the out-of-plane behavior of masonry structures. Furthermore, different types of structural analysis can be adopted for this complex behavior, such as limit analysis, pushover, or nonlinear dynamic analysis.

Aiming to evaluate the capabilities of different approaches to similar problems, blind predictions were made using different approaches. For this purpose, two idealized structures were tested on a shaking table and several experts on masonry structures were invited to present blind predictions on the response of the structures, aiming at evaluating the available tools for the out-of-plane assessment of masonry structures. This article presents the results of the blind test predictions and the comparison with the experimental results, namely in terms of formed collapsed mechanisms and control outputs (PGA or maximum displacements), taking into account the selected tools to perform the analysis.  相似文献   

9.
An extensive experimental program was carried out at EUCENTRE, within a research project on the evaluation and reduction of the seismic vulnerability of stone masonry structures. The main part of the experimental program has been devoted to the shaking table tests on three full-scale, two-story, single-room prototype buildings made of undressed double-leaf stone masonry. The first building tested was representative of existing unreinforced stone masonry structures with flexible wooden diaphragms, without any specific anti-seismic design nor detailing. In the second and third buildings, strengthening interventions were simulated on structures theoretically identical to the first one, improving wall-to-floor and wall-to-roof connections and increasing diaphragm stiffness. In particular, in the third specimen, steel and r.c. ring beams were used to improve the diaphragm connection to the walls and collaborating r.c. slab and multi-layer plywood panels were used to stiffen floor and roof diaphragms, respectively. This article describes the strengthening interventions applied to the third building prototype and presents the experimental results obtained during the shaking table tests. The results obtained permitted the calibration of a macroelement model representative of the nonlinear behavior of the structure.  相似文献   

10.
The sequence of earthquakes that has affected Christchurch and Canterbury since September 2010 has caused damage to a great number of buildings of all construction types. Following post-event damage surveys performed between April 2011 and June 2011, an inventory of the stone masonry buildings in Christchurch and surrounding areas was carried out in order to assemble a database containing the characteristic features of the building stock, as a basis for studying the vulnerability factors that might have influenced the seismic performance of the stone masonry building stock during the Canterbury earthquake sequence. The damage suffered by unreinforced stone masonry buildings is reported and different types of observed failures are described using a specific survey procedure currently in use in Italy. The observed performance of seismic retrofit interventions applied to stone masonry buildings is also described, as an understanding of the seismic response of these interventions is of fundamental importance for assessing the utility of such strengthening techniques when applied to unreinforced stone masonry structures.  相似文献   

11.
Different types of macro-elements have been proposed to simulate the behavior of unreinforced masonry (URM) structures under seismic loads. In many of these, macro-elements URM walls are replaced with beam elements with different hysteretic behaviors. The effect of out-of-plane loading or change of gravity load due to the overturning moment is usually not considered in the behavior of these macro-elements. This article presents interaction curves for bidirectional loadings of unreinforced masonry walls to investigate the importance of these factors. Two parameters are systematically changed to derive the interaction curves for a wall with specific dimensions, including compressive traction atop the wall to represent gravity loading, and loading angle that represents a combination of in-plane and out-of-plane earthquake loadings. Interaction curves are developed considering various possible failure modes for bricks and mortar, including tension, crushing and a combination of shear and compression/tension failures. The proposed interaction curves show the initiation of failure of URM walls as a function of compressive traction and loading angle. Several examples are presented for URM walls with different aspect ratios to aid in understanding the effects of various parameters on the derived interaction curves. Finally, for a specific case, the derived interaction curve is compared with nonlinear finite element results and ASCE41. The results show that, as a simplified method, the derived interaction curves can be used for the preliminary evaluation of URM walls under bidirectional loadings.  相似文献   

12.
ABSTRACT

Several architectural configurations of unreinforced masonry residential buildings are designed according to the different methods proposed in the Italian code: rules for the so-called simple masonry buildings, linear and nonlinear static analyses. Always complying with code requirements, for each building-site combination, the design was made, as much as possible, without an excessive margin of safety. The different design methods provided buildings with very different levels of safety, being linear static analysis largely overconservative with respect to the nonlinear static approach. These buildings were then analyzed in the companion paper.  相似文献   

13.
ABSTRACT

Kinetic analysis methods based on linear and nonlinear rigid body dynamics are used to evaluate earthquake safety of masonry structures. In this study, the formulas used to calculate the in-plane and out-of-plane load capacities of masonry load-bearing walls were evaluated and a procedure based on rigid body mechanism was proposed to calculate the out-of-plane load capacities of the walls of Ottoman period masonry mosques. New aspects of the method with respect to existing formulations is the inclusion of dynamic axial load and definition of the collapse limit spectral acceleration on the overturning wall. The calculated capacities of the mosque and individual walls were compared with the results of nonlinear pushover analysis and time history analyses performed under 1.0 and 0.5 scaled forms of nine different 3-component ground motion records. It was displayed that the seismic load capacity estimated by the proposed method is very close to the values calculated by pushover and time history analyses. The method was developed on Lala Pasha Mosque, and the reliability and applicability of the proposed methodology is verified on a different historical masonry mosque in comparison to finite element analyses results.  相似文献   

14.
Proposed in this paper are two analytical models for predicting the inelastic response of unreinforced brick masonry infills in reinforced concrete frames subjected to mono-tonic and reversed cyclic loading. The first model is based on the traditional diagonal strut concept, while the second one is a simple isoparametric element with shear deformation only. All the essential characteristics of the hysteretic behaviour of the panel, including strength and stiffness degradation, pinching and slippage, are explicitly taken into account. The models are implemented in a general-purpose program for the inelastic time-history analysis of structures, and are used for studying the seismic behaviour of typical multistorey frames with various arrangements of infill panels, including structures with an open ground storey. The results of the analysis are in agreement with both experimentally observed behaviour and with experience regarding seismically damaged buildings.  相似文献   

15.
Abstract

A summary of dynamic measurements are presented that illustrate relations between linear seismic demand and true nonlinear response of unreinforced masonry buildings with flexible diaphragms and rocking piers subjected to a series of simulated earthquake motions.  相似文献   

16.
This study addresses the problem of evaluation of strength of masonry walls. In-plane behavior of masonry panels has been studied under monotonic diagonal-compression and shear-compression loading in quasi-static test facility. The results of 35 laboratory and in situ tests are analyzed to show that in the case of the diagonal compression test results are lower than the strength of masonry walls evaluated trough the shear-compression test, highlighting the problem of choosing the test which best simulates to the real behavior of the masonry when stressed by lateral loads. A presentation is also given of the results of a F.E. investigation for shear strength evaluation of masonry walls. F.E. modeling non-linear procedure was used for the representation of masonry panels. The numerical simulations are compared with experimental results and the reliability of the different finite element models is discussed, thus confirming the different shear strength values measured in the experimental campaign.  相似文献   

17.
ABSTRACT

This article aims at contributing to the seismic performance assessment of a historic brick masonry building by finding a strength reduction coefficient through the use of linear and nonlinear modeling approaches, using Finite Element Method and Equivalent Frame modeling. To reduce the uncertainties, ambient vibration tests (AVT) were implemented. Series of simulations was performed using nonlinear dynamic analyses and incremental dynamic analysis curves were compared with the pushover curves. Results indicate that the mass-proportional pushover curve meets the mean of results obtained from IDA and the strength reduction coefficient falls into the range given in EN 1998–1 for unreinforced masonry.  相似文献   

18.
A large part of the building population in Switzerland is made of unreinforced masonry. For the assessment of the seismic risk the evaluation of the seismic vulnerability of existing unreinforced masonry buildings is therefore crucial. In this paper a method to evaluate existing buildings, which was developed for the earthquake scenario project for Switzerland, is briefly introduced and discussed in more detail for unreinforced masonry buildings. The method is based on a non-linear static approach where the seismic demand on the building is compared with the capacity of the building. In-plane and out-of-plane behaviour are considered. Comparisons with test results from model buildings show that the proposed method suitably forecasts the capacity of a building. Finally, a numerical example of the application of the method to a building in the city of Basel is given.  相似文献   

19.
The article presents seismic resistance evaluation study of unreinforced brick masonry buildings. The study was carried out as part of the Ph.D. research work of the first author. As part of the study, in addition to the standard laboratory tests, a dynamic field test was carried out on single-story, single-room unreinforced masonry structure. The model structure was tested in actual ground conditions against simulated earthquake vibrations produced through controlled explosions, especially designed for this purpose. Based on masonry properties accrued from lab and field tests, finite element models of the brickwork system were also studied. Finally, the software named, “Shear Damage Index (SDI),” developed as part of this study, was used to plot contours of shear demand (shear stress) to shear capacity (shear strength) ratio on the numerical model and hence to identify potential weak zones in the model for possible strengthening of those locations.  相似文献   

20.
ABSTRACT

Slender masonry structures such as towers, minarets, chimneys, and Pagoda temples can be characterized by their distinguished architectural characteristics, age of construction, and original function, but their comparable geometric and structural ratios yield to the definition of an autonomous structural type. These structures constitute a part of the architectural and cultural heritage. Their protection against earthquakes is of great importance. This concern arises from the strong damage or complete loss suffered by these structures during past earthquakes. Seismic vulnerability assessment is an issue of most importance at present time and is a concept widely used in works related to the protection of buildings. However, there is few research works carried out on developing the seismic vulnerability assessment tools for such structures.

This article presents a new method for assessing the seismic vulnerability of slender masonry structures based on vulnerability index evaluation method. The calculated vulnerability index can then be used to estimate structural damage after a specified intensity of a seismic event. Here, 12 parameters are defined to evaluate the vulnerability index for slender masonry structures. Implementation of this methodology is carried out in different types of slender masonry structures to develop vulnerability curves for these structure types.  相似文献   