首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Response of masonry walls to out-of-plane excitation is a complex, yet inadequately addressed theme in seismic analysis. The seismic input expected on an out-of-plane wall (or a generic “secondary system”) in a masonry building is the ground excitation filtered by the in-plane response of the walls and the floor diaphragm response. More generally, the dynamic response of the primary structure, which can be nonlinear, contributes to the filtering phenomenon. The current article delves into the details and results of several nonlinear dynamic time-history analyses executed within a parametric framework. The study addresses masonry structures with rigid diaphragm response to lateral loads. The scope of the parametric study is to demonstrate the influence of inelastic structural response on the seismic response of secondary systems and eventually develop an expression to estimate the seismic input on secondary systems that explicitly accounts for the level of inelasticity in the primary structure in terms of the displacement ductility demand. The proposed formulation is discussed in the companion article.  相似文献   

2.
The article presents seismic resistance evaluation study of unreinforced brick masonry buildings. The study was carried out as part of the Ph.D. research work of the first author. As part of the study, in addition to the standard laboratory tests, a dynamic field test was carried out on single-story, single-room unreinforced masonry structure. The model structure was tested in actual ground conditions against simulated earthquake vibrations produced through controlled explosions, especially designed for this purpose. Based on masonry properties accrued from lab and field tests, finite element models of the brickwork system were also studied. Finally, the software named, “Shear Damage Index (SDI),” developed as part of this study, was used to plot contours of shear demand (shear stress) to shear capacity (shear strength) ratio on the numerical model and hence to identify potential weak zones in the model for possible strengthening of those locations.  相似文献   

3.
This article addresses the results of a structural strengthening solution for rubble stone masonry walls. The strengthening includes inserting three-dimensional steel ties across the thickness of the walls and a 30-mm layer of air-lime and cement mortar render reinforced with glass fiber mesh (textile-reinforced mortar), on both sides of the wall. The strengthening solution was found to be efficient for rehabilitating ancient rubble stone masonry walls due to the “three-dimensional” confinement, provided by the steel wires, by offsetting the low cohesive capacity of the mortar used in the walls and thus improving the mechanical resistance and delaying the collapse mechanisms. This study is part of an experimental research program carried out in Universidade Nova de Lisboa, to evaluate structural strengthening solutions for ancient rubble stone masonry buildings. To this end, three specimens of rubble stone masonry walls without strengthening (unreinforced masonry) and other three, with the mentioned strengthening solution, were subjected to compression and shear load tests. Building materials were also tested in order to characterize physical, chemical and mechanical properties.  相似文献   

4.
Modern unreinforced masonry buildings with reinforced concrete slabs are often retrofitted by inserting reinforced concrete walls. The main advantages of this technique are the increase in strength and displacement capacity with respect to masonry structures. This article presents two modeling approaches for evaluating such structures: a shell-element model and a macro-element one. The objective is to formulate practical recommendations for setting up a macro-element model using as input the geometry of the structure and results from standard material tests. Structural configurations of masonry buildings, in which the insertion of reinforced concrete walls is an efficient retrofit technique, are also investigated.  相似文献   

5.
ABSTRACT

The seismic vulnerability assessment of historical UnReinforced Masonry (URM) buildings is a very complex task since it is strongly related to a great variety both of geometrical layouts and of masonry mechanical characteristics. In this article, some results of a Catania University research project, denomined “FIR 2014”, focused on the seismic vulnerability estimation of historical buildings, built in Catania after the 1963 earthquake, are presented. First, a detailed typological analysis of the considered urban fabric, characterized by typical residential masonry buildings, has been performed. Such analysis allowed recognizing an elementary structural modulus, which has been studied according to different geometrical layouts representative of isolated or aggregate buildings. The results of nonlinear static analyses, performed by applying an innovative macro-element approach, allowed for the assessment the seismic vulnerability of typical URM buildings coherently to the Italian seismic code. The adopted macro-element strategy for the seismic assessment of aggregate masonry buildings, although related to a specific historical center, may be applied to similar urban fabrics and can also be used for the calibration and validation of fast seismic assessment strategies, particularly useful for the evaluation of the seismic risk at urban scale.  相似文献   

6.
This paper presents a study on the techno-economic efficiency of seismic strengthening techniques for old residential buildings, with application to construction typologies in Lisbon (stone masonry and “Placa” buildings). A comprehensive review on strengthening techniques and implications for the seismic behavior is made. Different strengthening schemes are implicitly simulated within equivalent frame models of the representative buildings. Then, pushover analysis is applied in order to compare the seismic performance of the buildings, before and after strengthening. A cost-benefit analysis of the strengthening solutions is finally performed, comparing the economic benefit gained by reducing the seismic damage, against the intervention cost.  相似文献   

7.
An extensive experimental program was carried out at EUCENTRE, within a research project on the evaluation and reduction of the seismic vulnerability of stone masonry structures. The main part of the experimental program has been devoted to the shaking table tests on three full-scale, two-story, single-room prototype buildings made of undressed double-leaf stone masonry. The first building tested was representative of existing unreinforced stone masonry structures with flexible wooden diaphragms, without any specific anti-seismic design nor detailing. In the second and third buildings, strengthening interventions were simulated on structures theoretically identical to the first one, improving wall-to-floor and wall-to-roof connections and increasing diaphragm stiffness. In particular, in the third specimen, steel and r.c. ring beams were used to improve the diaphragm connection to the walls and collaborating r.c. slab and multi-layer plywood panels were used to stiffen floor and roof diaphragms, respectively. This article describes the strengthening interventions applied to the third building prototype and presents the experimental results obtained during the shaking table tests. The results obtained permitted the calibration of a macroelement model representative of the nonlinear behavior of the structure.  相似文献   

8.
9.
ABSTRACT

The paper analyzes the static behavior and the seismic vulnerability of the “San Francesco ad Alto” building in Ancona (Italy), which is currently used as a Regional Headquarter of the Marche Region by the Italian Army and was formerly a monastery. The global static structural behavior and the dynamic properties have been evaluated using the Finite Element modeling technique, in which the nonlinear behavior of masonry has been taken into account by proper constitutive laws. The concepts of homogenized material and smeared cracking are used to evaluate the capacity of the monastery to withstand lateral loads together with the expected demands resulting from seismic actions (N2 method), using a nonlinear static analysis (pushover). The comparison of seismic demand and capacity confirms the susceptibility of these types of buildings to extensive damage and collapse, as frequently observed in similar buildings. This paper aims to point out that advanced numerical analyses can offer significant information on the understanding of the actual structural behavior of historical buildings. It is believed that the methodology and the overall conclusions of this case study are valid for many historical monasteries in Europe.  相似文献   

10.
ABSTRACT

Although many experimental tests and numerical models are available in the literature, the numerical simulation of the seismic response of existing masonry buildings is still a challenging problem. While the nonlinear behavior of masonry structures is reasonably predictable when the out-of-plane behavior can be considered inhibited, when the in-plane and out-of-plane responses coexist and interact, simplified models seem unable to provide reliable numerical predictions. In this article, taking advantage of the experimental tests carried out in a shaking table on two masonry prototypes at LNEC, a macro-element approach is applied for the numerical simulations of their nonlinear response. The adopted approach allows simulating the nonlinear behavior of masonry structures considering the in-plane and out-of-plane responses. Since it is based on a simple mechanical scheme, explicitly oriented to representing the main failure mechanisms of masonry, its computational cost is greatly reduced with respect to rigorous solutions, namely nonlinear FEM approaches. Two modeling strategies are adopted, namely a regular mesh independent from the real texture of the prototypes and a detailed one coherent with the units disposal. The numerical results are discussed and the correlation between the nonlinear static analyses and the dynamic response is provided.  相似文献   

11.
In structural analyses, masonry infill walls are commonly considered to be non structural elements. However, the response of reinforced concrete buildings to earthquake loads can be substantially affected by the influence of infill walls. In this article, an improved numerical model for the simulation of the behavior of masonry infill walls subjected to earthquake loads is proposed and analyzed. First, the proposed model is presented. This is an upgrading of the equivalent bi-diagonal compression strut model, commonly used for the nonlinear behavior of infill masonry panels subjected to cyclic loads. Second, the main results of the calibration analyses obtained with two series of experimental tests are presented and discussed: one on a single frame with one story and one bay tested at the LNEC Laboratory; and the second, on a full-scale four story and three-bay frame tested at the ELSA laboratory.  相似文献   

12.
ABSTRACT

This article presents numerical simulations of two full-scale masonry structures which were tested on the shaking table within the scope of the workshop “Methods and challenges on the out-of-plane assessment of existing masonry buildings”. The numerical models have been developed on the basis of the blind-prediction models which have been improved after the publication of the test results. The solution procedure is divided into two steps with separate numerical simulations for each one. In the first step the collapse mechanism of the structure is determined by means of pushover analysis using a continuum, plasticity-based model. In the second step the dynamic response of the structure is simulated using a multibody model approach and frictional contacts. Results of the tests show reasonable, yet far from perfect predictive capabilities of the used numerical methods.  相似文献   

13.
This paper summarises the first phase of the fragility analyses of generic (representative) buildings in the area of Memphis, Tennessee, USA. The study was conducted at Cornell University as a part of the project Loss Assessment of Memphis Buildings (LAMB) for the National Center for Earthquake Engineering Research (NCEER). In this study, the fragility analyses focus on low-rise Lightly Reinforced Concrete (LRC) frame buildings with and without infill walls. The obtained fragility curves are compared with those of ATC-13 for different facility classes. Based on the obtained fragility curves, it is concluded that adding masonry infill wails to low-rise LRC frame buildings significantly reduces the likelihood of seismic damage.  相似文献   

14.
ABSTRACT

Historic heritage buildings are a part of historic basis of each society and an economic resource. Therefore, preserving and maintenance of these buildings are cultural, economic and social demand. This research investigates the seismic performance of a historical building named Arg of Tabriz (Arge Alishah) that dates back to 14th century and is located at the city center of Tabriz (NW of Iran). Static, modal, and finally nonlinear dynamic (time history) analysis were performed by both “Considering Soil-Structure Interaction (SSI)” and “fixed base (ignoring SSI)” Cases.

It is found from the results that, SSI extremely affects mode shapes and their frequencies and depending on the frequency content of the records, can has an incremental or decremental effect on structural responses. As expected, the building of Arg could carry gravity loads easily and despite its stability against earthquake loading in fixed base case, showed a weakness (especially in eastern and western walls direction) and overturned when it was analyzed in SSI case because of yielding of the surrounding soil.  相似文献   

15.
Considering the likely unfavorable behavior under seismic action of adobe construction, this article aims at providing a seismic fragility characterization of two adobe Portuguese traditional buildings, using numerical models calibrated over experimental results. The study of such two case-study buildings in the region of Aveiro contributes to the understanding of the seismic fragility of adobe construction in the region in general. The buildings were numerically modeled to estimate their structural behavior under seismic loading using adobe material properties that were calibrated based on the experimental results of a cyclic in-plane test of a full-scale double-Tshaped adobe wall. The method chosen to characterize adobe masonry and model its nonlinear behavior followed a total strain crack-based macro-modeling (TSCM) approach, whereas pushover analysis was carried out to reproduce the pseudo-static experimental test in order to enable a refined calibration of adobe masonry mechanical properties. Fragility functions were then derived, based on the above-mentioned numerical models, using nonlinear static analysis, bringing further insight on the seismic fragility of traditional Portuguese adobe construction.  相似文献   

16.
The eruption of Mount Vesuvius in 79 AD buried and preserved the Stabian Baths building in the exact configuration which the archaeological excavations carried out in the second half of the 19th century recovered. By combining archeologists’ studies with the analysis of deformations and cracking pattern due to the 1st century seismic events, in this article numerical models have been formulated which allowed the formation of some hypotheses coherent on the timeline of the events, the damage to as well as the change of the shape and stylistic language of the thermal building. Specifically, through global seismic analyses and kinematic analyses of masonry portions of the “destrictarium” block, it is proven that during the 1st century not only a sole catastrophic earthquake occurred but, at least, two important seismic events took place.

The purpose of this article is to identify and parameterize the responsible earthquake by the analysis of seismic effects detectable in the damages and archaeological remains of the masonry walls of the Stabian Baths. The identification of the earthquake and the grading of provoked damages represent a useful knowledge tool that provides information about the vulnerability of ancient buildings and can be suitably used also to safeguard architectural heritage from seismic risk.  相似文献   


17.
ABSTRACT

Observations after strong earthquakes show that out-of-plane failure of unreinforced masonry elements probably constitutes the most serious life-safety hazard for this type of construction. Existing unreinforced masonry buildings tend to be more vulnerable than new buildings, not only because they have been designed to little or no seismic loading requirements, but also because connections among load-bearing walls and with horizontal structures are not always adequate. Consequently, several types of mechanisms can be activated due to separation from the rest of the construction. Even when connections are effective, out-of-plane failure can be induced by excessive vertical and/or horizontal slenderness of walls (length/thickness ratio). The awareness of such vulnerability has encouraged research in the field, which is summarized in this article. An outline of past research on force-based and displacement-based assessment is given and their translation into international codes is summarized. Strong and weak points of codified assessment procedures are presented through a comparison with parametric nonlinear dynamic analyses of three recurring out-of-plane mechanisms. The assessment strategies are marked by substantial scatter, which can be reduced through an energy-based assessment.  相似文献   

18.
A large part of the building population in Switzerland is made of unreinforced masonry. For the assessment of the seismic risk the evaluation of the seismic vulnerability of existing unreinforced masonry buildings is therefore crucial. In this paper a method to evaluate existing buildings, which was developed for the earthquake scenario project for Switzerland, is briefly introduced and discussed in more detail for unreinforced masonry buildings. The method is based on a non-linear static approach where the seismic demand on the building is compared with the capacity of the building. In-plane and out-of-plane behaviour are considered. Comparisons with test results from model buildings show that the proposed method suitably forecasts the capacity of a building. Finally, a numerical example of the application of the method to a building in the city of Basel is given.  相似文献   

19.
In this article, the seismic behavior of RC wide beam-column connections designed primarily for gravity loads is evaluated experimentally. A 2/3 scale model of one exterior and one interior connection is constructed and subjected to seismic simulations on a shaking table until collapse. The results of the tests indicate that: (a) the drift at yield is from 3 to 6 times higher than, for example, the 0.5% admitted by Eurocode 8 to satisfy the “damage limitation requirement;” (b) the beam-column joints do not fail; (c) the torsion in the spandrel beams governs the overall load-displacement relationship of the exterior connections and limits the ultimate strength. Based on the test results, a nonlinear model for predicting the hysteretic behavior and the failure of the connections is suggested. The model can be implemented in a computer code for evaluating the vulnerability of this type of structure through nonlinear dynamic response analyses.  相似文献   

20.
Heritage stone buildings are typically vulnerable to seismic events. Results of an experimental program were analyzed to evaluate the shear strength and intrinsic damping of stone masonry representative of the West Block of the Canadian Parliamentary Precinct in Ottawa. Eight representative wall specimens with different rehabilitation schemes had been tested under different static and dynamic loadings. Each wall had wythes of sandstone and limestone connected by a rubble core. The results show the shear strength of the walls could be predicted accurately and that no strengthening scheme was particularly beneficial. The effective viscous damping ratios varied between 7 and 9%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号